A collection of sterile devices intended for short-term percutaneous access to the subarachnoid (intrathecal) or epidural space of the lumbar spinal column to drain cerebrospinal fluid (CSF), and/or other fluids of similar physical characteristics, as a mea...
A sterile implantable device intended to divert excessive cerebrospinal fluid (CSF) from the subarachnoid space of the lumbar spine to the peritoneal cavity, where it can be absorbed into the body, as a treatment for elevated intracranial pressure due to in...
An implantable component of a lumboperitoneal, ventriculoperitoneal or ventriculoatrial shunt designed to be connected to a lumbar, ventricular and/or peritoneal catheter (not included) to permit hypodermic infusion/injection of materials (e.g., chemotherap...
An implantable device intended to divert excessive cerebrospinal fluid (CSF) from the subarachnoid space of the lumbar spine to the peritoneal cavity where it can be absorbed into the body, as a treatment for raised CSF pressure (e.g., caused by hydrocephal...
A collection of sterile devices intended for short-term percutaneous access to the subarachnoid (intrathecal) or epidural space of the lumbar spinal column to drain cerebrospinal fluid (CSF) as a means of reducing CSF volume and intracranial pressure (ICP)....
A collection of devices intended for transient percutaneous access to the subarachnoid (intrathecal) or epidural space of the lumbar spinal column to obtain a sample of cerebrospinal fluid (CSF). Typical components include a spinal needle and collection tub...
A sterile collection of items designed for use with dimensionally compatible devices for draining cerebrospinal fluid (CFS) and other fluids of similar physical characteristics from the lumbar subarachnoid (intrathecal) region as a means of reducing intracr...
A sterile, noninvasive, battery-powered device designed to measure the cerebrospinal fluid (CSF) pressure/intracranial pressure via lumbar puncture. It is a small housing with an integrated transducer and pressure display intended to be connected to separat...
A sterile implantable tube that is a component of a lumboperitoneal (LP) shunt intended to channel cerebrospinal fluid (CSF) from the subarachnoid space of the lumbar spine in the management of elevated intracranial pressure due to increased CSF (hydrocepha...
A sterile implantable component of a lumboperitoneal shunt designed to regulate the pressure and flow of cerebrospinal fluid (CSF) from the subarachnoid space of the lumbar spine to the peritoneal cavity in the management of raised CSF pressure (e.g., cause...
A flexible tube intended to be percutaneously introduced for the repeated or continuous injection of local anaesthetics for preoperative, intraoperative, or postoperative regional anaesthesia and/or pain management; it may be placed in the epidural space, i...
A collection of sterile devices intended to be used with an intracerebral or spinal infusion/drainage catheter (not included) to collect drained cerebrospinal fluid (CSF), and other fluids of similar physical characteristics, from the brain ventricles or fr...
A sterile flexible tube intended for short-term percutaneous access to the subarachnoid (intrathecal) or epidural space of the lumbar spinal column for infusion of materials (typically anaesthetic or analgesic substances during surgery, labour, or delivery)...
A collection of sterile devices intended to be used with an intracerebral or spinal infusion/drainage catheter (not included) to collect drained cerebrospinal fluid (CSF) from the brain ventricles or from the lumbar subarachnoid (intrathecal) region as a me...
A sterile, flexible tube intended to be percutaneously introduced for the repeated or continuous injection of local anaesthetics for preoperative, intraoperative, or postoperative regional anaesthesia and/or pain management; it may be placed in the epidural...
A sterile, sharp bevel-edged, hollow tubular metal instrument intended to invasively access a peripheral nerve to inject an anaesthetic/analgesic agent for nerve-block/pain control (e.g., sleeve blocks, deep muscle blocks, hypogastric blocks, paravertebral ...
An implantable device intended to function as part of a lumboperitoneal, ventriculoperitoneal or ventriculoatrial shunt to regulate the pressure and flow level of cerebrospinal fluid (CSF) from the lumbar spine or brain to the peritoneum/heart right atrium ...
A sterile slender hand-held metal tube with a dull, straight or bent (coude) tip designed to atraumatically access a peripheral nerve for the injection of an anaesthetic/analgesic agent for nerve-block/pain control (e.g., sleeve blocks, deep muscle blocks, ...
An implantable device intended to create a fluid path connection between components of a cerebrospinal fluid (CSF) shunt assembly (e.g., lumbar and/or peritoneal catheters of a ventriculoperitoneal or lumboperitoneal shunt), designed to remove excess cerebr...
A sterile, flexible tube designed to be used for the creation of a void within a vertebral body during a minimally invasive procedure commonly known as balloon kyphoplasty. It is manually inserted percutaneously through an access channel under fluoroscopic ...
A sterile implantable tube that is a component of a lumboperitoneal (LP) shunt intended to channel cerebrospinal fluid (CSF) to the peritoneal cavity, where it can be absorbed into the body, in the management of elevated intracranial pressure due to increas...
A mains electricity (AC-powered) device designed to measure the cerebrospinal fluid (CSF) pressure in a patient using an appropriate pressure/electrical transducer. It is an electronic instrument that connects with a dedicated CSF access device (catheter, c...