A tubular device designed for percutaneous insertion into the bladder or renal pelvis through the suprapubic region. It typically consists of a metallic tube or a semi-rigid or rigid plastic tube that includes a trocar in its lumen to assist in the insertio...
A non-bioabsorbable tubular device typically implanted at the junction of the abdominal aorta and the common iliac arteries to reduce pressure on an abdominal aortic aneurysm (AAA) [includes aortoiliac aneurysm]; it does not contain anticoagulants or pharma...
A non-bioabsorbable tubular device typically implanted at the junction of the abdominal aorta and the common iliac arteries to reduce pressure on an abdominal aortic aneurysm (AAA); it does not contain anticoagulants or pharmaceuticals that prevent narrowin...
A non-bioabsorbable tubular device typically implanted at the junction of the abdominal aorta and the common iliac arteries to reduce pressure on an abdominal aortic aneurysm (AAA). It is percutaneously inserted via the femoral artery to the site of implant...
A sterile semi-rigid or rigid plastic or metal tube-shaped surgical instrument that is inserted into the lumen of the bronchus by means of a trocar providing rigidity. After insertion the trocar is withdrawn leaving a channel for suction or irrigation or th...
A cylindrical or bucket-like device designed as a removable component of a centrifuge rotor head intended to safely contain (hold) a laboratory test tube or centrifuge tube containing a sample/specimen while the centrifuge is being operated at high speeds. ...
A sterile, semi-rigid or rigid, plastic or, less frequently metal, tube designed for insertion into the uterus. It is frequently connected directly or through an external tube or catheter to an irrigator and/or aspirator for irrigation, infusion, or withdra...
A sterile, semi-rigid or rigid plastic or metal tube that is inserted through a nostril until the distal tip reaches into one of the nasal sinuses during a ear/nose/throat (ENT) procedure. It is connected directly or through an external tube or catheter to ...
A non-bioabsorbable tubular device intended to be implanted in the common and/or external iliac artery(ies) to maintain arterial patency and luminal diameter in patients with symptomatic atherosclerotic disease. It is made of metal [e.g., stainless steel, n...
A sterile non-bioabsorbable tubular device intended to be implanted in the common and/or external iliac artery(ies) to maintain arterial patency and luminal diameter in patients with symptomatic atherosclerotic disease. It is made of metal [e.g., stainless ...
A component of a rigid or flexible endoscope assembly designed as a tube through which an endoscope (e.g., hysteroscope) and endoscopic elements are introduced and assembled to create a complete operative endoscopic unit; it is also designed to function as ...
A rigid plastic or metal tube that is cone-shaped (i.e., it tapers down from a standard instrument fitting size to a small opening) and is either hand-held and manually inserted, or fitted onto a compatible otoscope, and then inserted into the ear canal to ...
A sterile, tube-like device designed to establish a channel for the removal of fluid or purulent material from a closed-wound or an infected area, typically used with a closed drainage system that applies a low negative pressure through the drain lumen. It ...
A component of a rigid or flexible endoscope assembly designed as a tube through which an endoscope (e.g., hysteroscope) and endoscopic elements are introduced and assembled to create a complete operative endoscopic unit; it is also designed to function as ...
A sterile flexible tube designed to provide percutaneous access to a peripheral nerve group for the insertion of a nerve-block blunt needle and injection of an anaesthetic/analgesic agent for nerve-block/pain control. It is typically made of plastic and con...
A device intended to be used in combination with a compatible flexible endoscope to collect cells of the mucosa for pathological diagnosis during endoscopy. It is inserted through the working channel of the endoscope and consists of a flexible insertion por...
A semi-rigid or rigid, plastic or metal tube that is cone-shaped (i.e., it tapers down from a standard instrument fitting size to a small opening) and is either hand-held and manually inserted, or fitted onto a compatible otoscope, and then inserted into th...
A hand-held manual surgical instrument intended to be used during surgical intervention of the trachea to dilate tracheal structures/passages, typically during the creation of a tracheostoma and/or for expanding the margins of a tracheostoma to assist in th...
A device used to remove dirt or debris from the working channel(s) and irregular surface of the endoscope prior to disinfection and sterilization. It consists of a flexible insertion tube or metal coil with plastic bristles. This is a reusable device.
A flexible device intended to be used through a flexible bronchoscope to obtain specimens of the bronchi for histological/pathological diagnosis during bronchoscopy. It is a type of biopsy forceps whose flexible insertion portion is made of a metal coil or ...
A device inserted into the stomach percutaneously to appose the anterior gastric wall to the anterior abdominal wall, typically to facilitate the insertion of a percutaneous gastrostomy tube or for procedures requiring stabilization/fixation of hollow gastr...
A device intended to be used in combination with a compatible flexible endoscope to collect cells of the mucosa for pathological diagnosis during endoscopy. It is inserted through the working channel of the endoscope and consists of a flexible insertion por...
A flexible, endotherapy device intended to be used through a flexible bronchoscope to obtain specimens of the bronchi for histological/pathological diagnosis during bronchoscopy. It is a type of biopsy forceps whose flexible insertion portion is made of a m...
A flexible device intended to be used through a flexible bronchoscope to obtain specimens of the bronchi for histological/pathological diagnosis during bronchoscopy. It is a type of biopsy forceps whose flexible insertion portion is made of a metal coil or ...
A sterile device intended to be used in combination with a compatible rigid endoscope to collect cells of the mucosa for pathological diagnosis during endoscopy. It is inserted through the working channel of the endoscope and consists of a rigid insertion p...
A sterile, hand-held manual surgical instrument intended to be inserted through an orogastric (or nasogastric) tube to mechanically divert the oesophagus away from the site of surgery during electrical treatments of the heart (e.g., cardiac ablation), to fa...