A semi-flexible, hand-held surgical instrument intended to be percutaneously introduced via a dedicated cannula [under computed tomography (CT), magnetic resonance imaging (MRI), or ultrasound (US) guidance] to deliver radio-frequency current in a monopolar...
A semi-flexible, hand-held surgical instrument intended to be percutaneously introduced via a dedicated cannula [under x-ray, ultrasound (US) or other external image guidance] to deliver radio-frequency current, in a monopolar configuration, from a system g...
A semi-flexible, hand-held surgical instrument intended to be percutaneously introduced via a dedicated cannula [under x-ray, ultrasound (US) or other external image guidance] to deliver radio-frequency current, in a monopolar configuration, from a system g...
A sterile, hand-held surgical instrument intended to be percutaneously introduced via a dedicated cannula [under external image guidance or using electrical stimulation for nerve location] to deliver radio-frequency current, in a monopolar configuration, fr...
A sterile, semi-flexible, hand-held surgical instrument intended to be percutaneously introduced via a dedicated cannula [under computed tomography (CT), magnetic resonance imaging (MRI), or ultrasound (US) guidance] to deliver radio-frequency current in a ...
A hand-held surgical instrument intended to be percutaneously introduced via a dedicated cannula [under external image guidance or using electrical stimulation for nerve location] to deliver radio-frequency current, in a monopolar configuration, from a syst...
A hand-held surgical instrument intended to be percutaneously introduced via a dedicated cannula [under external image guidance or using electrical stimulation for nerve location] to deliver radio-frequency current, in a monopolar configuration, from a syst...
An electrosurgical device intended to be connected directly to the arm of a robotic surgical system to deliver electrosurgical current in a monopolar configuration (i.e., in conjunction with a separate return electrode) from a generator directly to tissues ...
An electrosurgical device intended to be connected directly to the arm of a robotic surgical system to deliver electrosurgical current in both a bipolar and monopolar configuration from a generator directly to tissues for cutting/coagulation/ablation during...
An electrosurgical device which consists of a handpiece with mechanical and/or electrical controls, and a monopolar electrode, intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation/ablation during en...
A sterile, invasive, distal component of an electrosurgical assembly intended to deliver electrosurgical current in a monopolar configuration (i.e., used with a patient contact return electrode) to tissues for cutting/coagulation/ablation during endoscopic ...
An invasive, monopolar, electrical conductor intended to be attached to an appropriate handle/handpiece (not included) to deliver electrosurgical current directly to tissues for cutting/coagulation during an open surgical procedure. It may be available in a...
An invasive, distal component of an electrosurgical assembly intended to deliver electrosurgical current in a monopolar configuration (i.e., used with a patient contact return electrode) to tissues for cutting/coagulation/ablation during endoscopic (e.g., l...
An invasive, monopolar, electrical conductor intended to be attached to an electrosurgical handpiece (not included) to deliver electrosurgical current directly to tissues for cutting/coagulation during an open surgical procedure. It may be available in a va...
A rigid device consisting of combined electrosurgical handpiece and monopolar electrode intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation during an open surgical procedure. It is available in a v...
An electrosurgical device consisting of a handpiece with mechanical and/or electrical controls, and a monopolar electrode, intended to deliver a current from a system generator directly to tissues for cutting/coagulation/ablation during endoscopic (includin...
A rigid device consisting of combined electrosurgical handpiece and monopolar electrode intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation during an open surgical procedure. It is available in a v...
A sterile electrosurgical device which consists of a handpiece with mechanical and/or electrical controls, and a monopolar electrode, intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation/ablation du...
A flexible, tubular device designed to be inserted into the duodenum via the oral cavity (cannulation) using a flexible endoscope to: 1) infuse contrast media; and 2) deliver electrosurgical current in a monopolar configuration to cut the major duodenal pap...
A sterile electrosurgical device which consists of a handpiece with mechanical and/or electrical controls, and a monopolar electrode, intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation/ablation du...
A monopolar handpiece that is part of a skin contouring system that uses radio-frequency (RF) energy to provide a capacitively coupled electrical connection for the transfer of radiated energy through a patient's skin in deep heat-mediated skin modification...
A flexible tube intended to be used during a transseptal catheterization procedure to: 1) apply radio-frequency alternating current in a monopolar configuration, to puncture the interatrial septum and gain access to the left atrium; and 2) provide a fluid p...
A flexible, multi-purpose, tubular device designed to be inserted into the duodenum via the oral cavity (cannulation) using a flexible endoscope to: 1) infuse contrast media; 2) deliver electrosurgical current in a monopolar configuration to cut the major d...
A semi-flexible, hand-held instrument intended to be percutaneously introduced via a dedicated cannula under stereotactic guidance [e.g., using pre-acquired magnetic resonance imaging (MRI) images and fluoroscopy] to deliver radio-frequency current in a mon...
A flexible, multi-purpose, tubular device designed to be inserted into the duodenum via the oral cavity (cannulation) using a flexible endoscope to: 1) infuse contrast media; 2) deliver electrosurgical current in a monopolar configuration to cut the major d...
A sterile, hand-held surgical instrument intended to be introduced into the dermal layer of a patient’s skin (intradermal) to deliver radio-frequency current in a monopolar configuration from a system generator to coagulate/ablate superficial skin lesions (...
A sterile, flexible, steerable catheter intended to be used as part of a radio-frequency cardiac ablation system to apply radio-frequency alternating current to ablate areas of the endocardium of a beating heart in the treatment of cardiac arrhythmias; it i...
A sterile, flexible, steerable catheter intended to be used as part of a cardiac mapping system and/or a radio-frequency cardiac ablation system to transmit electrical pacing stimuli to, and electrical responses from, the heart for electrophysiological (EP)...
An assembly of devices that uses radio-frequency (RF) electromagnetic (EM) energy [typically in the bands below 10 megahertz (MHz)] to generate heat deep within subcutaneous tissues to temporarily minimize the manifestation of cellulite and loose or wrinkle...
An invasive, distal component of an inert gas-enhanced electrosurgical system intended to deliver electrosurgical current within a stream of inert gas [e.g., argon (Ar), helium (He)] directly to tissues for cutting/coagulation/ablation during an endoscopic ...