A collection of sterile devices intended to provide percutaneous access to a peripheral nerve group for injection of an anaesthetic/analgesic agent for nerve-block/pain control (e.g., sleeve blocks, deep muscle blocks, hypogastric blocks, paravertebral bloc...
A sterile flexible tube designed to provide percutaneous access to a peripheral nerve group for the insertion of a nerve-block blunt needle and injection of an anaesthetic/analgesic agent for nerve-block/pain control. It is typically made of plastic and con...
A non-sterile, hand-held, mechanical device intended to aid introduction of a cannula/needle subcutaneously into fatty tissue for use with an insulin infusion pump. It typically consists of a small housing that chambers the cannula and a triggered release m...
A collection of devices intended to be used to tighten loose or wrinkled skin and, optionally, cosmetically remove fat, through rotational force and suction provided by a dedicated console. It consists of a multiple coring needle array used to create a matr...
A collection of sterile devices intended to be used during a needle entry procedure (e.g., central venous access, aspiration of pneumothorax) that combines ultrasonic and electromagnetic methods for needle guidance (e.g., needle depth data using Hall effect...
A hollow slender tubular instrument designed for percutaneous insertion to provide access for instruments (e.g., biopsy needle) under radiological image guidance [e.g., ultrasound] during procedures relating to tissue lesions (e.g., biopsy, ablation). The c...
A hollow slender tubular instrument designed for percutaneous insertion to provide access for instruments (e.g., biopsy needle) under radiological image guidance [e.g., ultrasound] during procedures relating to tissue lesions (e.g., biopsy, ablation). The c...
A metal implant intended to be attached (sutured) to, or placed above, an arteriovenous fistula (AVF) under the skin to act as a guide when using a constant site (buttonhole) method of blunt needle insertion. It is typically used during haemodialysis proced...
A collection of devices intended to conveniently provide some of the components necessary for the ambulatory administration of insulin to a patient with diabetes mellitus. It consists of a sterile needle/cannula within a housing, a skin-adhesive patch/holde...
A hand-operated, non-electronic, surgical instrument designed for the automatic extraction of a small tissue sample from an anatomical structure (a biopsy), while causing minimal surrounding tissue damage, for tissue pathological examination/testing. It con...
An invasive tubular surgical instrument designed to be connected to a biopsy gun handpiece (not included) for the automatic extraction of a small tissue sample from an anatomical structure (a biopsy), while causing minimal surrounding tissue damage, for tis...
A collection of sterile devices, equipment, and supplies used to obtain a bone specimen from the vertebrae of a patient (the bony segments of the spinal column) for histological analysis. It typically contains a metal cannula which can have various tip desi...
A small, sterile, stand-alone, needleless plastic valve intended to mate two related intravenous (IV) line devices [e.g., hypodermic syringe and catheter port or tubing from an IV administration set] and hold them in a secured, sealed, locked position, and ...
A collection of devices, equipment, and supplies used to obtain a bone specimen from the vertebrae of a patient (the bony segments of the spinal column) for histological analysis. It typically contains a metal cannula which can have various tip designs (e.g...
A rigid or semi-rigid tube (non-illuminating) designed to be inserted into the eye to facilitate infusion, irrigation, and/or aspiration of fluids/gases during ophthalmic surgery (e.g., phacoemulsification, vitreoretinal surgery, sub-Tenon’s anaesthesia, ca...
A rigid or semi-rigid tube (non-illuminating) designed to be inserted into the eye to facilitate infusion, irrigation, and/or aspiration of fluids/gases during ophthalmic surgery (e.g., phacoemulsification, vitreoretinal surgery, sub-Tenon’s anaesthesia, ca...
A short, thin tube intended to be inserted into a peripheral vein (typically on the hand/arm) to enable short-term (< 30 days) intravenous (IV) access for administration of fluids/medication and blood sampling. Also referred to as a peripheral IV catheter, ...
A sterile, noninvasive, non-luminal, electronic device designed to be connected to an appropriate invasive luminal device (e.g., catheter, cannula, tube, needle), to detect pressures (e.g., blood, gastrointestinal, urinary pressures) within the lumen and tr...
A sterile, sharp bevel-edged, hollow tubular metal instrument designed to access the epidural space. It may be used to deliver anaesthetic or analgesic agents or to introduce a dedicated catheter for continuous anaesthesia administration. If used with a sty...
A hard-walled container designed for the safe deposit and collection of biologically or chemically contaminated used sharps; this includes needles, lancets, scalpel blades, cannulae, or other devices that present a hazard to a healthcare worker or patient i...
A device designed as a container to allow the safe deposit and collection of biologically or chemically contaminated used sharps; this includes needles, lancets, scalpel blades, cannulae, or other devices that present a hazard to a healthcare worker or pati...
A rigid or semi-rigid luminal device (dental tip) intended to channel and dispense a dental material/solution [e.g., restorative amalgam, resin, etching solution (etchant), topical dental anaesthetic] from a dental syringe, or similar applicator, to a patie...
A sterile, sharp, hollow tubular metal instrument designed for percutaneous insertion to provide access to any bone of the body for a bone biopsy needle or guidewire, or for a bone marrow aspiration technique, or for inserting therapeutic materials, includi...
A collection of sterile devices intended to be used to prepare and/or deliver bone graft material during an orthopaedic surgical procedure. It typically includes aspirating/delivery/mixing syringe(s), an adaptor, and a needle/cannula. It allows for the aspi...
A collection of sterile manual devices intended to create a percutaneous access channel within a vertebral body or other bones (e.g., hand, radius, tibia, calcaneus) prior to the use of an inflatable balloon (e.g., a balloon catheter or balloon tamp) to cre...
A sterile, bioabsorbable, bacteria-derived substance intended to be injected into the dermis/hypodermis of the skin, lip submucosa, and/or for supraperiosteal administration to add volume by serving as a space-occupying supplement to the intercellular matri...
A collection of various instruments/devices (e.g., introducer sheath, dilator, guides, cannula, needle, angiographic catheter) intended to be used for percutaneous body-access to facilitate a radiological image-guided interventional radiology or surgical pr...
A slender, hollow, tubular, metal instrument with a blunt tip designed specifically for irrigation of the root canal of a tooth during an endodontic procedure. Sometimes referred to as a root canal irrigation cannula, it is typically attached to a dental sy...