A sterile electrical conducting device designed to be inserted percutaneously into muscle or nerve tissue to detect bioelectrical signal activity. It is a needle-like device (a needle electrode with an electrical connector at the proximal end) that is conne...
An electrical conducting device designed to be inserted percutaneously into muscle or nerve tissue to detect bioelectrical signal activity. It is a needle-like device (a needle electrode with an electrical connector at the proximal end) that is connected to...
A sterile, sharp bevel-edged, hollow tubular metal instrument designed to be used: 1) as a bipolar electrode for real-time bioimpedance-based prediction of the needle tip location; and 2) for lumbar puncture/intrathecal injection. The needle and an included...
An insulated metal wire(s) designed to conduct electrical signals between a skin electrode(s) or needle electrode(s) [electrode not included] and a device designed for electrophysiological recording/monitoring [e.g., electromyography (EMG), evoked potential...
An assembly of devices designed to apply electrical stimuli in one peripheral region of the body while the response is monitored in another peripheral region. It typically consists of external electrodes (e.g., hand-held bipolar or ring electrodes) or needl...
An insulated metal wire(s) designed to conduct electrical signals between a skin electrode(s) or needle electrode(s) [electrode not included] and a device designed for electrophysiological recording/monitoring [e.g., electromyography (EMG), evoked potential...
A collection of dedicated electrodes intended to support a variety of electrophysiological measurements [e.g., electrocardiography (ECG), electroencephalography (EEG), electromyography (EMG), intraoperative monitoring (IOM), evoked potentials (EP)]. It incl...
A collection of devices designed to be used with a dedicated nonimplantable pulse generator for the delivery of electrical stimuli to the sacral nerve, via percutaneous tibial nerve stimulation (PTNS), to treat urinary and/or faecal incontinence. It typical...
A sterile hand-held component of an ultrasound-guided intrauterine electrosurgical system consisting of both a handpiece and a monopolar electrode designed to provide an electrical connection between the output terminals of a dedicated electrosurgical gener...
A sterile device designed as a needle-shaped electrode used together with a hair-removal electrolysis system and used to destroy the dermal papilla (hair root) through application of an electric current from the parent device via the tip of this device that...
An electrical conductor intended to be inserted percutaneously into interstitial tissue to continuously measure and record interstitial-fluid glucose concentrations, typically for detecting trends and tracking patterns in patients with diabetes mellitus. It...
A device designed as a needle-shaped electrode used together with a hair-removal electrolysis system and used to destroy the dermal papilla (hair root) through application of an electric current from the parent device via the tip of this device that is inse...
An invasive, monopolar, electrical conductor intended to be attached to an appropriate handle/handpiece (not included) to deliver electrosurgical current directly to tissues for cutting/coagulation during an open surgical procedure. It may be available in a...
An invasive, monopolar, electrical conductor intended to be attached to an electrosurgical handpiece (not included) to deliver electrosurgical current directly to tissues for cutting/coagulation during an open surgical procedure. It may be available in a va...
A flexible wire with an electrode, insulated with non-conductive material except at its ends, that serves as an electrical conductor between the heart and an external temporary pacing/defibrillation device used to treat postoperative cardiac arrhythmias/car...
An electrically-powered unit designed to be used specifically to apply electrical stimuli to acupuncture sites (electroacupuncture). It is an external low-intensity, low frequency pulse (usually 1 to 100 pulses per second), multimode generator intended to c...
A flexible, invasive, endoscopic device intended to deliver both: 1) a submucosal lifting solution; and 2) an electrosurgical current in a monopolar configuration (i.e., with a return electrode) to tissues for cutting/coagulation. It is typically intended t...
An assembly of devices intended to permanently remove unwanted body hair by destroying the dermal papilla (hair root) through application of an electric current at the tip of a fine needle electrode that is inserted close to the hair shaft, under the skin, ...
An assembly of devices used to apply precisely timed and repeatable electrical stimuli to the peripheral nerves, typically for evoked potential and other research procedures (e.g., functional mapping in epilepsy). It is usually a multichannel external stimu...
An assembly of battery-powered devices designed to treat urinary and/or faecal incontinence with electrical stimuli applied to the sacral nerve via percutaneous tibial nerve stimulation (PTNS). It consists of a pair of electrodes, a needle electrode placed ...
A sterile, steerable, thin, flexible tube containing multiple electrodes that is introduced percutaneously into the heart chambers in order to relay information to an external cardiac mapping system to create a three-dimensional (3-D) electromechanical reco...
An assembly of devices intended to permanently remove unwanted body hair by destroying the dermal papilla (hair root) through application of an electric current at the tip of a fine needle electrode that is inserted close to the hair shaft, under the skin, ...
An assembly of devices intended to be used in the home by a layperson to remove unwanted body hair using electrical current applied directly, or intended to be applied indirectly, to the dermal papilla (hair root). It includes a hand-held, battery-powered u...
A flexible tube intended to be used for the percutaneous transluminal passage and placement of a diagnostic/interventional catheter, lead (e.g., pacing lead, balloon dilatation catheter), needle or guidewire through its lumen(s), within the vascular system....
A sterile device intended to functions as: 1) an electrode during nerve/nerve plexus location; and 2) as a conduit for administration of a local anaesthetic during peripheral nerve-blocking. It is a sharp, hollow, tubular, electrically-insulated metal needl...
A flexible tube intended to be used for the percutaneous transluminal passage and placement of a diagnostic/interventional catheter, lead (e.g., pacing lead, balloon dilatation catheter), needle or guidewire through its lumen(s), within the vascular system....
A small, electronic device with micro-needle(s) intended to be inserted percutaneously into interstitial tissue to continuously measure and record interstitial fluid glucose concentrations, typically for detecting trends and tracking patterns in patients wi...
A sterile, needle-like device intended to be inserted percutaneously into interstitial tissue to continuously measure and record interstitial-fluid glucose concentrations, typically for detecting trends and tracking patterns in patients with diabetes mellit...
A needle-like device intended to be inserted percutaneously into interstitial tissue to continuously measure and record interstitial-fluid glucose concentrations, typically for detecting trends and tracking patterns in patients with diabetes mellitus. It is...
A flexible, invasive, endoscopic device assembly intended to deliver: 1) a submucosal lifting solution; 2) an electrosurgical current in a bipolar configuration to tissues for cutting; and 3) microwave energy to tissues for coagulation. It is typically inte...