A hand-held surgical device intended to be connected to a neurosurgical retraction obturator during brain surgery to allow mounting of devices (e.g., navigational devices) to the obturator/cannula assembly during introduction into brain tissues. It is typic...
A manual device intended to connect a neurosurgical retraction obturator to a probe (e.g., stereotactic/electromagnetic surgery system probe), typically of incompatible sizes. It typically incorporates a male rod-like attachment intended to fit into the lum...
A surgical device designed to fill the lumen of a drill guide during its insertion to a surgical site primarily to prevent tissue obstruction of the drill guide lumen. When the drill guide is firmly placed at the chosen position on the bone surface, the obt...
A device designed to fill the lumen of a tracheostomy tube during its insertion into the stoma created in the larynx (windpipe) to assist in this process, reduce patient trauma, and prevent any tissue damage. When the tracheostomy tube is correctly position...
A hand-held manual surgical instrument with a sharp pyramidal or conical point intended to be used to create a percutaneous puncture using the transobturator approach (i.e., insertion points overlie the obturator space and the obturator foramen membrane is ...
A single-lumen surgical device designed to be used with an obturator to atraumatically displace brain tissues without tissue penetration (e.g., careful insertion between gyri) to create a surgical access corridor to a specific lesion/abnormality within the ...
A collection of sterile, nonimplantable, invasive devices intended to provide percutaneous vascular access to enable introduction of a catheter (not included) into the vascular system. It includes a non-steerable introducer sheath with an inner obturator/di...
A collection of nonimplantable, invasive devices intended to provide percutaneous vascular access to enable introduction of a catheter (not included) into the vascular system. It includes a non-steerable introducer sheath with an inner obturator/dilator, an...
A hand-held manual dental instrument designed for direct warm bonding during an endodontic obturation procedure. It is preloaded (encased) with a resin-based sealing, filling, and core material at its distal working end which is subsequently heated in a ded...
An endoscopic device that is a component of a rigid endoscope assembly that has a distally rounded, solid, head or end that is placed into the sheath of a rigid endoscope in order to fill out the sheath's lumen (open end), thereby assisting its insertion in...
A single-lumen surgical device intended to be percutaneously inserted into a joint to create an access port for an arthroscope/arthroscopic instrument during arthroscopy. The cannula is designed to facilitate the passage of surgical instruments while preven...
A sharp bevel-edged, hollow tubular metal instrument designed to make the initial percutaneous puncture to access a vein and/or artery during vascular catheterization. It is available in a variety of forms to enable a catheter to be introduced directly, or ...
A sterile, sharp bevel-edged, hollow tubular metal instrument designed to make the initial percutaneous puncture to access a vein and/or artery during vascular catheterization. It is available in a variety of forms to enable a catheter to be introduced dire...
A single-lumen, surgical device intended to be percutaneously inserted into a joint to create an access port for an arthroscope/arthroscopic instrument during arthroscopy. The cannula is designed to facilitate the passage of surgical instruments while preve...
A non-sterile, hand-held manual surgical instrument designed to fill the lumen of an arthroscopic sleeve (not included) to facilitate insertion of the sleeve into a joint (e.g., shoulder, knee) during arthroscopic examination or surgery. It is typically can...
A collection of devices used to puncture the chest wall to enable insertion of a dedicated catheter for the aspiration of a simple pneumothorax or decompression of a tension pneumothorax. It typically consists of a scalpel to make a stab incision and a need...
A hand-held manual surgical instrument designed to create a subcutaneous tunnel (artificial passageway) between percutaneous entry and exit incisions for the subcutaneous placement of a device (e.g., catheter for medication administration, shunt). It is ava...
An endoscope with a rigid inserted portion intended for the visual examination and treatment of the anus and rectum. It is inserted into the body through the anus during anoscopy. The inserted portion is short in length, though longer than a sphincteroscope...
A slender, sharply-pointed metal tube designed to introduce or remove gas from the peritoneal cavity as a therapeutic or surgical/radiological procedural method. It is often inserted into the peritoneal cavity for the purpose of insufflation [e.g., with car...
A sterile, hand-held manual surgical instrument designed to create a subcutaneous tunnel (artificial passageway) between percutaneous entry and exit incisions for the subcutaneous placement of a device (e.g., catheter for medication administration, shunt). ...
A hand-held manual surgical instrument designed to create a subcutaneous tunnel (artificial passageway) between percutaneous entry and exit incisions for the subcutaneous placement of a device (e.g., catheter for medication administration, shunt, retinal ch...
A hand-held component of a tissue morcellation system intended to be used to mechanically cut (slice), core (cut a hole into), peel (remove surface), and extract selected tissue from the body during surgery. It consists of a high-speed rotating blade in a h...
A collection of sterile surgical instruments and materials used to locally occlude the blood flow to internal haemorrhoids for their removal. The collection typically includes a ligator preloaded with several ligatures (e.g., latex rubber bands) deployed to...
An endoscope with a rigid inserted portion intended for the visual examination and treatment of the anus and rectum. It is inserted into the body through the anus during anoscopy. The inserted portion is short in length, though longer than a sphincteroscope...
A sterile device designed to seal the sheath of a haemostasis valve to maintain sheath patency (i.e., to prevent blood from coagulating in the sheath and blocking access through the haemostasis valve). It is typically a long, thin, rod-like device made of p...
An endoscope with a rigid inserted portion intended for the visual examination and treatment of the anus and rectum. It is inserted into the body through the anus during anoscopy. The inserted portion is short in length, though longer than a sphincteroscope...
An assembly of devices designed to deliver preheated resin-based sealing, filling, and core materials into a root canal for direct warm bonding during an endodontic obturation procedure. It typically consists of a mains electricity (AC-powered) oven used to...
A collection of sterile devices, equipment, and supplies used to obtain a bone specimen from the vertebrae of a patient (the bony segments of the spinal column) for histological analysis. It typically contains a metal cannula which can have various tip desi...
A slender, sharply-pointed metal tube designed to introduce or remove gas from the peritoneal cavity as a therapeutic or surgical/radiological procedural method. It is often inserted into the peritoneal cavity for the purpose of insufflation [e.g., with car...
A device designed to dissect connective tissue layers creating access to a desired surgical site during a laparoscopic procedure. It typically consists of a cannula, a distention balloon, an obturator, an inflation bulb, and a regulating valve(s). An approp...