A collection of sterile devices designed to implant a cardiac occluder for the non-surgical closure of cardiac defects. The collection may include a delivery catheter/sheath, dilator, loading device, delivery cable, and additional items for the intravascula...
A collection of devices designed to implant a cardiac occluder (not included) for the non-surgical closure of cardiac defects. The collection may include a delivery catheter/sheath, dilator, loading device, delivery cable, and additional items for the intra...
A sterile device intended to be used as a dedicated tool for the insertion and/or removal of a hypopharyngeal fistula occluder. It is in the form of a thin tube with a mechanism for attaching the occluder at the distal end so that it can be pulled into, or ...
A plug-like device intended to be inserted into a catheter (e.g., Foley catheter), or a catheter-like invasive device, to prevent flow through one or more orifice(s) in the catheter; it may also be referred to as a catheter spigot or catheter tip occluder. ...
A sterile plug-like device intended to be inserted into a catheter (e.g., Foley catheter), or a catheter-like invasive device, to prevent flow through one or more orifice(s) in the catheter; it may also be referred to as a catheter spigot or catheter tip oc...
A collection of devices which includes an implantable device(s) intended to provide percutaneous, peripheral, arterial access to enable repeated introduction of a catheter (not included) into the vascular system over an extended period (e.g., months) withou...
A sterile, disk-like, device used for the non-surgical closure of cardiac defects. The device is typically self-expandable and made of wire mesh [e.g., nickel-titanium alloy (Nitinol)], and possibly additional materials (e.g., polyester). It is implanted us...
An implantable disk-like device intended to be used for the minimally-invasive closure of cardiac defects and deployed using a dedicated delivery catheter/sheath. It is made of wire mesh [e.g., nickel-titanium alloy (Nitinol)], and possibly additional mater...
A non-sterile, hand-held manual instrument designed to assist in the non-surgical placement of a tracheoesophageal device (e.g., speech valve, speech valve occluder, fistula gauge/dilator). It is a synthetic polymer holder onto which the tracheoesophageal d...
A device designed to temporarily occlude the flow of blood in the lumen of a blood vessel at a vascular anastomosis, primarily to control bleeding and enable operative field visualization during coronary or peripheral vascular bypass grafting and vessel rep...
A sterile device designed to temporarily occlude the flow of blood in the lumen of a blood vessel at a vascular anastomosis, primarily to control bleeding and enable operative field visualization during coronary or peripheral vascular bypass grafting and ve...
A device intended to be used to mechanically stop or interrupt the flow of blood in veins or arteries temporarily during vascular surgery and emergency trauma surgery. It is typically designed with a ring having a small portion left open so that it can be s...
An implantable disk-like device intended to be used for the minimally-invasive closure of cardiac defects and deployed using a dedicated delivery catheter/sheath. It is made of wire mesh [e.g., nickel-titanium alloy (Nitinol)], and possibly additional mater...
A device intended to be used to mechanically stop or interrupt the flow of blood in veins or arteries temporarily during vascular surgery and emergency trauma surgery. It is typically designed with a ring having a small portion left open so that it can be s...
A semi-soft device designed to be inserted into the vagina to maintain pneumoperitoneum during removal of the uterus during laparoscopic hysterectomy. It is in the form of a cylinder with ridges and is made of synthetic polymer materials. This is a single-u...
A device intended to be used to mechanically stop or interrupt the flow of blood in veins or arteries temporarily during vascular surgery and emergency trauma surgery. It is typically designed with a ring having a small portion left open so that it can be s...
An implantable disk-like device intended for the minimally-invasive closure of cardiac defects and deployed using a dedicated delivery catheter/sheath. It is made of wire mesh [e.g., nickel-titanium alloy (Nitinol)], and possibly additional materials (e.g.,...
A non-sterile device intended to be placed in a surgically-created tracheoesophageal fistula/puncture (usually for more than 30 days) to: 1) maintain its shape and patency following total laryngectomy; and 2) to prevent leakage of fluids from the oesophagus...
A device intended to be temporarily inserted into the tracheal end of a tracheoesophageal speech valve (typically indwelling type) to prevent leakage of fluids from the oesophagus into the trachea during swallowing; it is not intended to enable voice produc...
A non-sterile device intended to be temporarily inserted into the tracheal end of a tracheoesophageal speech valve (typically indwelling type) to prevent leakage of fluids from the oesophagus into the trachea during swallowing; it is not intended to enable ...
A hand-operated, non-powered ophthalmic device intended to temporarily prevent and/or attenuate the passage of light (vision) to the eye(s) during an eyesight examination (e.g., diagnosis/measurement of heterophoria/heterotropia, myopia). The part of the de...
A thin, plastic, flap-like device that is clipped onto the upper frame of a pair of existing spectacles (eyeware) to block vision through the spectacle lens. It is typically made of plastic and is available in preformed, leaf-shaped, disks, usually with a p...
A device used to hold prisms, spheres, cylinders, or occluders on a trial lens frame or set of spectacles during vision testing. This is a reusable device.
A device intended to be used to mechanically stop or interrupt the flow of blood in veins or arteries temporarily during vascular surgery and emergency trauma surgery. It is typically designed with a ring having a small portion left open so that it can be s...
A sterile device intended to be used for the non-surgical short-term (i.e., < 30 days) occlusion of a fistula in the upper end of the oesophagus (hypopharynx), typically where the fistula has an external opening, to prevent leakage of oesophageal content. I...
A hand-held manual instrument designed to assist in the non-surgical placement of a tracheoesophageal device (e.g., speech valve, speech valve occluder, fistula gauge/dilator). It is a synthetic polymer holder onto which the tracheoesophageal device is dist...
A hand-held, manual non-surgical instrument intended to dilate a surgically-created tracheoesophageal fistula (puncture) to facilitate insertion of a tracheoesophageal device (typically a non-indwelling tracheoesophageal speech valve); it may in addition be...
A non-sterile, hand-held, manual non-surgical instrument intended to dilate a surgically-created tracheoesophageal fistula (puncture) to facilitate insertion of a tracheoesophageal device (typically a non-indwelling tracheoesophageal speech valve); it may i...
A hand-held, manual non-surgical instrument intended to dilate a surgically-created tracheoesophageal fistula (puncture) to facilitate insertion of a tracheoesophageal device (typically a non-indwelling tracheoesophageal speech valve); it may in addition be...
A hand-held, manual non-surgical instrument intended to dilate a surgically-created tracheoesophageal fistula (puncture) to facilitate insertion of a tracheoesophageal device (typically a non-indwelling tracheoesophageal speech valve); it may in addition be...