An independent mechanical device designed for accurate mixing of air and oxygen (O2) with O2 concentrations ranging from 21% to 100% (oxygen/air proportioner) that are appropriated for breathing in patients who need a concentration of O2 above the normal co...
An electronic device intended to measure the length of time of gas circulation, typically compressed gases delivered at a fixed pressure through a section of conduit or pipe. This device usually consists of a housing containing the electronics and measuring...
An independent mechanical device designed for accurate mixing of helium (He) and oxygen (O2) with concentrations ranging from 80% He and 20% O2, or 70% He and 30% O2 (helium/oxygen proportioner) that are appropriated for breathing in a patient who is indica...
A portable non-electronic device intended to mix ambient air with compressed oxygen (O2) to generate a flow of oxygen rich air to a patient at a pre-set (non-adjustable) inspired oxygen concentration (FiO2) [e.g., pre-set at 28-33%], for continuous positive...
A portable non-electronic device intended to mix ambient air with compressed oxygen (O2) to generate a flow of oxygen rich air to a patient with adjustable inspired oxygen concentration (FiO2) [e.g., 28-100%] and adjustable flow rate, for continuous positiv...
A device designed to provide or assist ventilation in a patient who is apnoeic or exhibits inadequate respiration through automatic pneumatic-driven pressure cycle functions. It is connected to a source of compressed oxygen (O2) and, if not entrained, medic...
A non-sterile device designed to provide or assist ventilation in a patient who is apnoeic or exhibits inadequate respiration through automatic pneumatic-driven pressure cycle functions. It is connected to a source of compressed oxygen (O2) and, if not entr...
A device designed to hold and secure a single medical gas cylinder of compressed medical gas which is to be used in medical treatment/therapy. The usual gases are, [e.g., oxygen (O2), air, or nitrous oxide (N2O)]. It is used to secure the cylinder both duri...
A dedicated cart designed to hold and secure one or more medical gas cylinders of compressed gas; but may be used for other types of gases, both during transport and static placement. The usual gases are [e.g., oxygen (O2), air, nitrous oxide (N2O) or heliu...
A portable assembly of devices, which includes a non-surgical invasive component, intended to aspirate unwanted materials (e.g., fluids, secretions) from the airway typically during patient transport or an emergency situation (e.g., placed on a crash cart),...
An independent mechanical device designed for accurate mixing of oxygen (O2) and air or O2 and nitrous oxide (N2O) in pre-set concentrations appropriated for breathing. The mixer receives all three gases from either the hospital gas pipeline or from compres...
A length of reinforced colour-coded flexible tubing produced according to ISO5359 intended to conduct a specific compressed medical gas mixture (e.g., helium/oxygen, nitrous oxide/oxygen mixture) from a specific terminal unit or cylinder to an appropriate r...
"A length of reinforced colour-coded flexible tubing produced according to ISO5359 intended to conduct a specific compressed medical gas mixture (e.g., helium/oxygen, nitrous oxide/oxygen mixture) from a specific terminal unit or cylinder to an appropriate ...
An assembly of devices designed to supply compressed medical gases [e.g., oxygen (O2), nitrous oxide (N2O), medical air, surgical-grade air] from a central source to endpoints throughout a medical facility. The system typically consists of several gas suppl...
A length of flexible tube intended to conduct compressed oxygen (O2) from an O2 terminal unit or O2 cylinder to a medical device that functions with O2 (e.g., ventilators, anaesthesia units, anaesthesia systems, analgesia units and other O2 dependent respir...
A container designed as a refillable cylinder with an integrated pressure regulator used to hold compressed medical oxygen (O2) under safe conditions at high pressure (e.g., 50 - 200 Bar). It is typically filled with O2 when delivered from the gas supplier ...
A container designed as a refillable cylinder used to hold compressed medical oxygen (O2) under safe conditions at high pressure (e.g., 50 - 200 Bar). It is typically filled with O2 when delivered from the gas supplier and includes a valve stem, an opening/...
A container designed as a refillable cylinder with an integrated pressure regulator used to hold compressed medical oxygen (O2) under safe conditions at high pressure (e.g., 50 - 200 Bar). It is typically filled with O2 when delivered from the gas supplier ...
A container designed as a refillable cylinder used to hold compressed medical oxygen (O2) under safe conditions at high pressure (e.g., 50 - 200 Bar). It is typically filled with O2 when delivered from the gas supplier and includes a valve stem, an opening/...
A container designed as a refillable cylinder used to hold a compressed mixture of 79% helium (He) and 21% oxygen (O2) under safe conditions at high pressure (e.g., 50 - 150 Bar). It is typically filled with He/O2 when delivered from the gas supplier and in...
An assembly of devices designed to evacuate fluid, tissue, gas, or other foreign materials from a body cavity or lumen by means of suction. It generally consists of a suction pump powered by compressed air or oxygen from a hospital's central gas system, tub...
An assembly of devices comprising a medical gas/vacuum pipeline system designed to supply compressed medical gases [oxygen (O2), nitrous oxide (N2O), medical air, surgical-grade air] and vacuum from a central source to outlets and/or inlets throughout a med...
A noninvasive device/collection of noninvasive devices designed to convert positive gas pressure from a compressed gas supply, into negative pressure (the Venturi principle) for the evacuation of fluids, mucus, or solids during a range of clinical applicati...
A length of reinforced colour-coded flexible tubing produced according to ISO5359 intended to conduct compressed oxygen (O2) from an O2 terminal unit or O2 cylinder to a medical device that functions with O2 (e.g., ventilators, anaesthesia unit, analgesia u...
A length of reinforced colour-coded flexible tubing produced according to ISO5359 intended to conduct compressed oxygen (O2) from an O2 terminal unit or O2 cylinder to a medical device that functions with O2 (e.g., ventilators, anaesthesia unit, analgesia u...
"A length of reinforced colour-coded flexible tubing produced according to ISO5359 intended to conduct compressed oxygen (O2) from an O2 terminal unit or O2 cylinder to a medical device that functions with O2 (e.g., ventilators, anaesthesia unit, analgesia ...
A container designed as a refillable cylinder used to hold a compressed mixture of 50% nitrous oxide (N2O) and 50% oxygen (O2) under safe conditions at high pressure (e.g., 50 - 150 Bar). It is typically filled with N2O/O2 when delivered from the gas suppli...
An assembly of pneumatically-powered devices, which includes a surgically invasive component, designed to aspirate debris/tissues/fluids from body cavities/wounds during a surgical procedure; it may in addition have non-surgical applications. It is connecte...
A mains electricity (AC-powered) device, which may include rechargeable batteries, intended to assist noninvasive ventilation (i.e., without use of an artificial airway) of a neonatal/infant patient via an attached nasal cannula or mask, using continuous po...
A portable, manually-operated, noninvasive device intended to be used in conjunction with a separate compressed oxygen (O2) source and airway access device (e.g., cricothyrotomy kit) for transtracheal ventilation of a patient in an emergency situation where...