A hand-held, battery-powered instrument designed to measure the concentration of dissolved oxygen (DO) in solutions, typically in the field. It typically consists of an electronic unit that processes an electric signal from a sensor and displays oxygen conc...
A device designed to detect the presence and determine the concentration of oxygen (O2) by paramagnetic, electrochemical, or other technique. The device is typically used as a component of an oxygen monitor or a patient monitoring device/system that determi...
A collection of consumable devices designed to work together to deliver humidified pure oxygen (O2) or an O2 enriched gas to a mask or nasal cannula during oxygen administration to a patient (e.g., oxygen therapy, anaesthesia). It includes oxygen administra...
A battery-powered instrument designed to continuously measure the concentration of oxygen (O2) inspired by a patient in a respiratory maintenance/therapy setting (e.g., O2 in an anaesthesia or ventilator breathing circuit, oxygen tent, oxygen therapy device...
A mains electricity (AC-powered) instrument designed to continuously measure the concentration of oxygen (O2) inspired by a patient in a respiratory maintenance/therapy setting (e.g., O2 in an anaesthesia or ventilator breathing circuit, oxygen tent, oxygen...
A fibreoptic cord designed for bidirectional transmission of light between a patient monitor and a sensor catheter (e.g., intracerebral sensor catheter). It is typically used for transmitting light used to measure intracerebral partial pressure of oxygen (p...
An electrically-powered unit designed to be connected to a pulse oximeter sensor and used during the administration of oxygen (O2) to a spontaneously breathing patient, for: 1) continuous monitoring of physiologic parameters, especially haemoglobin oxygen s...
A mains electricity (AC-powered) photoelectric device that noninvasively measures the brain tissue blood oxygen saturation and venous oxygen saturation in the brain. It is typically used as an adjunct monitor for the regional haemoglobin oxygen saturation o...
A non-active implantable hydrogel device designed to be injected into subcutaneous tissue (typically in the limbs) to sense and convey tissue oxygen levels by emitting fluorescent (phosphorescent) signals when excited by an external light source, whereby th...
A device consisting of a rigid/semi-rigid transparent plastic shell that forms an enclosure over an infant's whole body, or the head only, in order to provide an enriched environment of oxygen (O2) to increase the patient's O2 uptake. It is connected to an ...
A device consisting of a rigid transparent plastic shell forming an enclosure over the head of an adult, typically to provide an enriched oxygen (O2)environment to increase the patient's O2 uptake. It is connected to an O2 source and may be used concurrentl...
An assembly of devices designed to provide supersaturated oxygen (SSO2) therapy to targeted ischemic regions of a patient's coronary vasculature immediately following revasculization by means of percutaneous coronary intervention (PCI) with stenting. It is ...
A device intended to be used with a transcutaneous blood gas monitor to measure a patient's blood partial pressure of oxygen (pO2), blood partial pressure of carbon dioxide (pCO2), and/or blood oxygen saturation transcutaneously (through the skin). Gases di...
A device assembly designed to continuously measure and display multiple vital physiological parameters of newborn and premature infants, especially those under critical care. It is typically capable of monitoring parameters such as electrocardiogram (ECG), ...
A device/device assembly designed to continuously measure and display multiple vital physiological parameters of newborn and premature infants, especially those under critical care. It is typically capable of monitoring parameters such as electrocardiogram ...
A photoelectric device that is applied externally to a site on the body surface of a paediatric or adult patient for transcutaneous measurement the percent oxygen saturation of haemoglobin in a volume of tissue (StO2) to assess the amount of oxygen delivere...
A photoelectric device designed to be applied externally to the scalp/head of a patient for transcutaneous measurement [e.g., using near-infrared spectroscopy (NIRS)] of brain tissue blood oxygen saturation and/or venous oxygen saturation in the brain. It c...
A mains electricity (AC-powered) photoelectric device that noninvasively calculates the percent oxygen saturation of haemoglobin in a volume of tissue (StO2) to assess the amount of oxygen delivered to that tissue, typically during circulatory or perfusion ...
A photoelectric device that is applied externally to a site on the body surface of a paediatric or adult patient for transcutaneous measurement the percent oxygen saturation of haemoglobin in a volume of tissue (StO2) to assess the amount of oxygen delivere...
A flexible tube containing a fibreoptic bundle designed to conduct light at a selected wavelength through blood to detect the reflected or scattered light for the estimation of blood oxygen concentration. It detects with a sensor at its distal end and is us...
A wearable, battery-powered device designed to actively promote continuous diffusion of oxygen (CDO) in a wound to help heal various types of wounds (e.g., arterial, venous, diabetic or pressure ulcers, skin grafts, burns, postoperative or traumatic wounds)...
An electrically-powered device designed to deliver heated and humidified ambient air or air/oxygen to a patient during both: 1) high-flow (exceeding peak inspiratory flow) respiratory therapy; and 2) bi-level positive airway pressure (BPAP). It consists of ...
An electrically-powered device intended to be used to continuously measure the partial pressure of oxygen (pO2) in tissues during clinical procedures at high risk for tissue hypoxia (e.g., neurosurgery, skin graft surgery) or during patient critical care (e...
A mobile, mains electricity (AC-powered) device designed to use laser Doppler techniques to measure the velocity of micro- and macrovascular blood circulation to assess of the extent of vascular flow restrictions [e.g., clots, stenosis, mechanical damage, a...
A mains electricity (AC-powered) device designed for the continuous measurement and display of blood gas and related parameters when blood is circulated outside of the body in a closed system. It is typically used with an appropriate sensor or sensor casset...
A flexible tube with a sensor at the distal end intended to be surgically inserted through the skull for short-term (= 30 days) access to the ventricular and/or parenchymal areas of the brain to measure intracranial parameters [e.g., intracranial pressure (...
A sterile flexible tube with a sensor at the distal end intended to be surgically inserted through the skull for short-term (= 30 days) access to the ventricular and/or parenchymal areas of the brain to drain cerebrospinal fluid (CSF) and to measure intracr...
A flexible tube with a sensor at the distal end intended to be surgically inserted through the skull for short-term (= 30 days) access to the ventricular and/or parenchymal areas of the brain to measure intracranial parameters [e.g., intracranial pressure (...
An electronic device designed to be used to monitor the conditions of a specific environment. It may be used to monitor environmental parameters such as air temperature, relative humidity, or atmospheric oxygen concentration. This device, designed as a cabl...