A device that is a component of a medical gas pipeline system or a medical gas/vacuum pipeline system that has a gas-specific outlet connection for medical air. It is designed to be mounted to wall-mounted medical supply units, utility supply systems (ceili...
A device that is a component of a medical gas pipeline system or a medical gas/vacuum pipeline system that has a gas-specific outlet connection for nitrogen (N2). It is designed to be mounted to wall-mounted medical supply units, utility supply systems (cei...
A device that is a component of a medical gas pipeline system or a medical gas/vacuum pipeline system that has a gas-specific outlet connection for oxygen (O2). It is designed to be mounted to wall-mounted medical supply units, utility supply systems (ceili...
A component of a medical vacuum supply pipeline system designed to stop (close off) the vacuum in a vacuum distribution pipeline in cases of emergency or maintenance. This device is installed in the pipeline and is manually activated by service personnel/tr...
A device designed to connect to the vacuum terminal unit (wall outlet) of a vacuum pipeline system to control the degree of negative pressure (vacuum) provided by the system and applied in the evacuation of fluids, mucus or solids from the trachea. The devi...
A reduction valve designed to lower high and variable gas pressure in a pipeline intended for surgical applications (e.g., to drive surgical power tools) to a lower and constant working pressure, typically 3 - 12 bar. It consists of a housing containing a s...
A mains electricity (AC-powered) device designed to create compressed air, normally of medical grade, and supply it to a hospital or institution's gas pipeline/supply system. Ambient air is filtered, compressed by this device, then cleaned and stored in a p...
An assembly of devices comprising a medical gas/vacuum pipeline system designed to supply compressed medical gases [oxygen (O2), nitrous oxide (N2O), medical air, surgical-grade air] and vacuum from a central source to outlets and/or inlets throughout a med...
A component of a medical gas pipeline system designed as an exchangeable filter to trap the impurities of the air that is being produced by, e.g., a hospital's compressors, and that passes through it. It is composed of tightly woven materials through which ...
A device that is typically a component of a medical gas pipeline system designed to reduce high incoming pressure from a gas supply (e.g., bank of cylinders or tank) to an operational pressure safe for patients and laboratory devices. It is typically compos...
A noninvasive device/collection of noninvasive devices designed to connect to the terminal unit (wall outlet) of a vacuum pipeline system to control the degree of negative pressure during the evacuation of fluids, mucus, or solids during a range of clinical...
An independent mechanical device designed for accurate mixing of oxygen (O2) and air or O2 and nitrous oxide (N2O) in pre-set concentrations appropriated for breathing. The mixer receives all three gases from either the hospital gas pipeline or from compres...
A screening device designed for use with a surgical smoke evacuation system, to entrap particulates from the plume of smoke created typically through the use of various tissue-burning surgical devices (e.g., laser, electrosurgical diathermy device), to prev...
An assembly of devices designed to evacuate fluid, tissue, gas, or foreign materials from a body cavity or lumen by means of suction. It is connected via dedicated vacuum tubing to the vacuum terminal unit (wall outlet) of a vacuum pipeline system and power...
An independent mechanical device designed for accurate mixing of air and oxygen (O2) with O2 concentrations ranging from 21% to 100% (oxygen/air proportioner) that are appropriated for breathing in patients who need a concentration of O2 above the normal co...
An assembly of vacuum-powered devices, which includes a surgically invasive component, designed to aspirate unwanted materials (e.g., debris, tissues, fluids) from body cavities/wounds during a surgical procedure (e.g., general surgery, laparoscopy); it may...
A male connecting device used to connect to a medical gas pipeline system or other gas source allowing a user to rapidly connect and disconnect nitrous oxide (N2O) dependent devices to the N2O supply. It has safety features such as a specific mechanical mat...
An assembly of devices designed to supply compressed medical gases [e.g., oxygen (O2), nitrous oxide (N2O), medical air, surgical-grade air] from a central source to endpoints throughout a medical facility. The system typically consists of several gas suppl...
A male connecting device intended to be used to connect to a medical gas/vacuum pipeline system or other vacuum connection allowing a user to rapidly connect and disconnect vacuum dependent devices to the vacuum source. It has safety features such as a spec...
A male connecting device used to connect to a medical gas pipeline system or other gas source allowing a user to rapidly connect and disconnect oxygen (O2) dependent devices to the O2 supply. It has safety features such as a specific mechanical mating patte...
A male connecting device used to connect to a medical gas pipeline system or other gas source allowing a user to rapidly connect and disconnect medical air dependent devices to the medical air supply. It has safety features such as a specific mechanical mat...
A male connecting device used to connect to a medical gas pipeline system or other gas source allowing a user to rapidly connect and disconnect nitrogen (N2) dependent devices to the nitrogen supply. It has safety features such as a specific mechanical mati...
An empty receptacle designed to hold a disinfection solution for subsequent disinfection of a medical device (e.g., dental suction system, water pipeline); it is not intended to hold medical devices or to be used during a medical procedure. It is available ...
A male connecting device used to connect to the anaesthetic gas scavenging (AGS) terminal unit of a medical gas pipeline system or a female AGS connector allowing a user to rapidly connect and disconnect an anaesthetic gas scavenging system (AGSS) for the c...
A mains electricity (AC-powered) unit intended to heat water and pump the hot water into the ringline/pipeline of a reverse-osmosis haemodialysis water purification system for cleaning and disinfection. It typically consists of a heater, pump, and connectors.
A noninvasive device/collection of noninvasive devices designed to connect to the terminal unit (wall outlet) of a vacuum pipeline system to control the degree of negative pressure during the evacuation of fluids (e.g., blood), secretions, or gases from the...
A mains electricity (AC-powered) component of a pneumatic/ultrasonic intracorporeal lithotripsy system designed to regulate the energy delivered to fragment the stones (i.e., renal, ureteral, urethral, and bladder calculi) for their removal. It is typically...
A pneumatically-powered external device designed for the application of rhythmic compression to the chest in the region of the heart to provide blood flow during treatment of cardiac arrest [cardiopulmonary resuscitation (CPR)]. It is typically powered from...
An independent mechanical device designed for accurate mixing of helium (He) and oxygen (O2) with concentrations ranging from 80% He and 20% O2, or 70% He and 30% O2 (helium/oxygen proportioner) that are appropriated for breathing in a patient who is indica...
A reference standard device intended to represent one end of a medical quick-connect coupling or a terminal unit of a gas-specific format [e.g., oxygen (O2), nitrous oxide (N2O), medical air], which may be used to evaluate connection port compatibility and ...