A connecting device designed as a mechanical coupling to join and lock together a distal tool to the surgical power tool to provide the power when these are incompatible and are of a different manufacture/industry standard. It is typically made from high-gr...
A device intended to connect a surgical power tool (e.g., pneumatically or electrically driven motors, turbines, or attachments) to a maintenance device (i.e., maintenance unit or lubricant container) during maintenance/lubrication of the surgical power too...
An electrically-powered one-piece device or modular device collection designed to accept an endpiece(s) [e.g., drill bit, saw blade, bur] for drilling, cutting, and/or inserting procedures involving bones and tough tissues during a surgical procedure; it is...
An electrically-powered one-piece device or modular device collection designed to accept an endpiece(s) [e.g., drill bit, saw blade, bur] for drilling, cutting, and/or inserting procedures involving bones and tough tissues during a non-dental surgical proce...
A pneumatically-powered one-piece device or modular device collection designed to accept an endpiece(s) [e.g., drill bit, saw blade, bur] for drilling, cutting, and/or inserting procedures involving bones and tough tissues during a non-dental surgical proce...
An electrically-powered one-piece device or modular device collection designed to accept an endpiece(s) [e.g., drill bit, saw blade, bur] for drilling, cutting, and/or inserting procedures involving bones and tough tissues during a non-dental surgical proce...
A device used for the automatic internal lubrication and maintenance of surgical power tools (e.g., pneumatically or electrically driven motors, turbines, or attachments). This device will automatically run programs for the lubrication of the internal compo...
A dental attachment, commonly known as a ratchet adaptor, drive converter, or dental turbine, designed to be fitted in a dental power tool handpiece to convert energy (e.g., electrical, pneumatic) to a rotational mechanical motion to achieve a specific func...
A dental attachment, commonly known as a ratchet adaptor, drive converter, or dental turbine, designed to be fitted in a dental power tool handpiece to convert energy (e.g., electrical, pneumatic) to a sagittal, oscillating or reciprocating mechanical motio...
A collection of surgical devices intended to provide both rotary (e.g., drilling, reaming) and sawing (e.g., oscillating, reciprocating) motions for drilling, cutting, or inserting procedures involving bones and tough tissues (e.g., cartilage, ligaments) us...
An insulated electrical cord designed with a mains electricity supply plug at one end and single or multiple outlet socket clusters at the other end, intended to enable a connection between a medical device and a mains electricity supply. It is typically us...
A non-absorbent, non-powered, hand-held device in the form of a brush, a wire, strip of metal, or handle intended to clean the exterior and/or interior (lumen) of a surgical instrument (e.g., bur, reamer, bone tap, suturing device, sheath/shaft, ultrasonic ...
A non-absorbent, non-powered, hand-held device in the form of a brush, a wire, strip of metal, or handle intended to clean the exterior and/or interior (lumen) of a surgical instrument (e.g., bur, reamer, bone tap, suturing device, sheath/shaft, ultrasonic ...
An electrically-powered one-piece device or modular device collection designed to accept an endpiece(s) [e.g., drill bit, saw blade] for drilling, cutting, polishing, and/or inserting procedures involving bones and tough tissues during a dental surgical pro...
A pneumatically-powered one-piece device or modular device collection designed to accept an endpiece(s) [e.g., drill bit, saw blade] for drilling, cutting, polishing, and/or inserting procedures involving bones and tough tissues during a dental surgical pro...
A non-absorbent, non-powered, hand-held device in the form of a brush, a wire, strip of metal, or handle intended to clean the exterior and/or interior (lumen) of a surgical instrument (e.g., bur, reamer, bone tap, suturing device, sheath/shaft, ultrasonic ...
A non-absorbent, non-powered, hand-held device in the form of a brush, a wire, strip of metal, or handle intended to clean the exterior and/or interior (lumen) of a surgical instrument (e.g., bur, reamer, bone tap, suturing device, sheath/shaft, ultrasonic ...
An insulated electrical cord designed to enable connection of a medical device to a mains electricity supply socket, with a male and a female connector (plug) at either end. It is manufactured to medical grade standards for use in healthcare facilities and ...
A mobile assembly of mains electricity (AC-powered) devices intended to provide a physician with optical tools to track manual surgical instruments and locate target anatomical structures with respect to pre-acquired images (e.g., CT/MRI scan) or real-time ...
A mobile assembly of electrically-powered devices intended to provide a physician with optical tools to track manual surgical instruments and locate anatomical structures with respect to pre-acquired images (e.g., CT/MRI scan) or real-time data [e.g., endos...
A small, non-powered, noninvasive, tubular two-way/linear connector with an ENFit connection (designed according to ISO 80369-3 for enteral applications) at one end and a connection which is not designed according to ISO 80369 at the other end (typically ba...
A non-powered small connecting device, which includes an integrated nebulizer, intended to join a sterile water or sterile isotonic sodium chloride solution reservoir to a respiratory gas source (typically wall outlet) and a gas administration device (e.g.,...
A mobile assembly of electrically-powered devices intended to provide a physician with optical tools to track manual surgical instruments and locate anatomical structures with respect to pre-acquired images (e.g., CT/MRI scan) or real-time data [e.g., endos...
An assembly of battery-powered, personal-worn, devices designed to amplify the loudness of the voice of a person with reduced vocal capacity (e.g., due to impairment of throat or chest muscles, partial paralysis of vocal cords, diminished lung capacity). It...
A small, sterile, connecting device designed to fit between the component devices of an ultrasonic surgical system (i.e., the handpiece tip, handpiece, and generator) to enable them to join each other. It may include controls (e.g., buttons) that allow the ...
A small connecting device designed to fit between the component devices of an ultrasonic surgical system (i.e., the handpiece tip, handpiece, and generator) to enable them to join each other. It may include controls (e.g., buttons) that allow the operator t...
An electrically-powered, multi-jointed, mechanical device intended to support and elevate a patient¿s femur for optimal positioning during hip replacement surgery. It is designed to be fixed to an operating table and includes a vertical lifting post, an ele...
An assembly of devices designed to automatically pipette liquids in the laboratory for the preparation/concentration of analytes (e.g., cells, nucleic acids, microorganisms) in clinical specimens (e.g., blood, urine, sputum, faeces). It is software operated...
A battery-powered, hydraulically-operated device designed to be installed within an ambulance to support the loading and unloading of an ambulance stretcher, to improve the safety and ease of patient transfer to and from the ambulance. It is typically a sem...
A mains electricity (AC-powered) component of a mechanical atherectomy system designed to inject cooled normal sterile saline and/or surgical lubricant via the system’s dedicated catheter into the site of crossing a chronic partial occlusion (CPO) or chroni...