Irregular Pulse Drops
Irregular Pulse Drops
34 matching records for PULSE.
Irregular Pulse Drops
Ammonium Carbonate and Sodium Carbonate
20251126
2026-01-10
An electronic instrument designed to simulate arterial oxygen saturation and/or pulse rate for testing and calibrating pulse oximeters, pulse oximeter probes and other related pulse oximetry devices.
An electrical conductor used to connect a pulse generator analyser to the leads of an implantable pulse generator (IPG) [i.e., an implantable pacemaker or automatic implantable cardioverter-defibrillator (AICD)] to test the function of the generator during ...
An electronic instrument designed to simulate arterial oxygen saturation and/or pulse rate for testing and calibrating pulse oximeters, pulse oximeter probes and other related pulse oximetry devices.
An assembly of battery-powered devices designed to provide ventilatory support to a patient with diaphragm dysfunction of neuromuscular origin through electrical stimulation of the phrenic nerve to contract the diaphragm rhythmically and cause the patient t...
An electronic instrument designed to test an external pacemaker to ensure compliance with performance specifications. The device connects to the output of the pacemaker to test any or all of the pulse generator's parameters including pulse duration, pulse a...
A photoelectric component of a pulse Co-oximeter that is applied externally to a body part (e.g., a fingertip for adults, the hand or foot for neonates), for the transcutaneous multiwave measurement of carboxy-haemoglobin saturation (SpCO) and typically sev...
A photoelectric component of a pulse Co-oximeter that is applied externally to a body part (e.g., a fingertip for adults, the hand or foot for neonates), for the transcutaneous multiwave measurement of carboxy-haemoglobin saturation (SpCO) and typically sev...
A mains electricity (AC-powered) mobile (on wheels) device that combines technologies and may include an intense pulsed light (IPL) or IPL with radio-frequency (RF) generator, fluorescent light generator, pulsed ultraviolet B (UVB) light generator, Er:YAG l...
An implantable device intended to extend the electrical connection between a spinal cord/peripheral nerve implantable analgesic electrical stimulation system pulse generator and a lead(s). It typically includes small connectors to enable attachment to the l...
A noninvasive assembly of mains electricity (AC-powered) devices designed to apply weak, pulsed (not continuous) electrical stimuli to a patient's brain to treat one or more psychiatric disorders which may include anxiety, depression, insomnia, and/or addic...
A noninvasive assembly of electrically-powered devices designed to apply weak, pulsed (not continuous) electrical stimuli to a patient's brain to treat one or more psychiatric disorders which may include anxiety, depression, insomnia, and/or addiction; it m...
An implantable wire with an electrode, insulated with non-conductive material except at its ends, which serves as an electrical conductor to transmit pacing impulses from an implanted pulse generator to the heart; it is not intended to conduct defibrillatio...
An assembly of devices designed to improve glycaemic control and induce weight loss in obese patients with type 2 diabetes mellitus by monitoring intrinsic electrical and mechanical gastric activity and delivering gastric contractility modulation (GCM) sign...
An automated, mains electricity (AC-powered), portable electronic device designed to measure multiple cardiovascular parameters [including electrocardiogram (ECG), phonocardiogram (PCG), carotid pulse tracing, femoral pulse tracing and four limb pulse traci...
A noninvasive, electrically-powered device intended to function as a communication interface between an implantable pulse generator (IPG) [e.g., spinal cord electrical stimulation implantable pulse generator] and an external IPG programmer, to enable a clin...
A collection of devices designed to be used with a dedicated nonimplantable pulse generator for the delivery of electrical stimuli to the sacral nerve, via percutaneous tibial nerve stimulation (PTNS), to treat urinary and/or faecal incontinence. It typical...
A portable, battery-powered, photoelectric device intended for the transcutaneous measurement and display of haemoglobin oxygen saturation (SpO2). The signals, typically produced by light-emitting diodes (LEDs) and a receiving detector in a probe, or direct...
A mains electricity (AC-powered) photoelectric device intended for the continuous transcutaneous measurement and display of haemoglobin oxygen saturation (SpO2). The signals, typically produced by light-emitting diodes (LEDs) and a receiving detector in a p...
A hand-held, electrically-powered device designed to be used in the home to produce strong, controlled flashes of filtered light in the wavelength range of 400 - 1200nm [intense pulsed light (IPL)] for self-removal of unwanted hair.
An electrically-powered photoelectric device designed for the transcutaneous measurement and display of haemoglobin oxygen saturation (SpO2). The signals are produced by light-emitting diodes (LEDs) and received by a photodetector. The device displays the S...
A sterile, implantable, battery-powered device consisting of a hermetically-sealed pacing pulse generator and an integrated defibrillation pulse generator with leads in the right ventricle, in a coronary vein over the left ventricle, and often in the right ...
An external device intended to enable a healthcare professional in a clinical setting to noninvasively change the settings of, and extract data from, an implanted cardiac pulse generator (e.g., pacemaker, pacemaker/defibrillator). It includes a radio-freque...
A small unit dedicated to the transcutaneous measurement of haemoglobin oxygen saturation (SpO2) in blood using light detection methods (spectrophotometry) after light is emitted from a light-emitting diode (LED) situated in the connected probe. It is desig...
A portable, battery-powered, electronic device designed to detect hypoxia (oxygen deficiency at the tissue level) via the transcutaneous multiwave measurement and display of carboxy-haemoglobin saturation (SpCO) and typically other related parameters such a...
An external device intended to enable a layperson to noninvasively extract data from an implanted cardiac pulse generator (i.e., therapeutic active cardiac implant) to provide historic and/or current information on device performance, and may in addition be...
A mains electricity (AC-powered) mobile (on wheels) device designed to produce strong, controlled flashes of filtered light in the wavelength range 400 - 1200nm [intense pulsed light (IPL)] for heat ablation of pigmented skin cells (selective photothermolys...
A battery-powered, hand-held device designed to apply an electromagnetic (EM) field to body deep tissues to help reduce pain associated with musculoskeletal/neurological disorders (e.g., arthritis, sciatica) and/or to treat soft-tissue wounds and injuries w...
A mains electricity (AC-powered) mobile (on wheels) device designed to produce strong, controlled flashes of filtered light in the wavelength range 560 - 1200nm [intense pulsed light (IPL)] to cause heat ablation of pigmented skin cells (selective photother...
A portable, photoelectric device intended for the transcutaneous monitoring of haemoglobin oxygen saturation (SpO2) through the radio transmission/reception of SpO2 values. The signals, typically produced by light-emitting diodes (LEDs) and a receiving dete...
A mains electricity (AC-powered) component of a high frequency chest wall oscillation airway secretion-clearing system intended to produce oscillating pressurized air-pulses that are delivered to an inflatable vest via a dedicated thick-walled hose. The air...