A device designed to protect a haemodialysis system pressure monitor from contamination and to help maintain the sterility of the blood tubing fluid pathway. It is typically attached between the blood tubing set and the pressure monitor and typically consis...
A length of pneumatic tubing with an integrated electrical cable intended to be connected to the existing tubing/cable of a blood pressure/neuromuscular transmission monitoring cuff (not included) to increase its length, during combined intraoperative nonin...
A sterile device designed to protect a haemodialysis system pressure monitor and to help maintain the sterility of the blood tubing fluid pathway. It is typically attached between the blood tubing set and the pressure monitor and typically consists of plast...
A mains electricity (AC-powered) device, with a rechargeable battery, that is a component of a cerebrospinal fluid pressure regulation system designed to monitor/display cerebrospinal fluid (CSF) pressure, and to aspirate CSF at a rate regulated by CSF pres...
A sterile component of a cerebrospinal fluid pressure regulation system that consists of tubing and integrated mechanical pressure sensor designed to monitor cerebrospinal fluid (CSF) pressure to regulate drainage rate. It is intended to be taped to the pat...
An assembly of devices designed to simultaneously monitor cerebrospinal fluid (CSF) pressure and aspirate CSF at a rate regulated by the desired intracranial or in-tube CSF pressure. It is connected to a dedicated CSF access device (e.g., catheter, needle) ...
A non-powered, portable component of an intraocular pressure-reducing vacuum system designed for the noninvasive, bilateral reduction of intraocular pressure (IOP) by creating a reduced pressure environment around the eye for the treatment of open-angle gla...
A collection of devices that includes the necessary tubing and other items, e.g., connectors, stopcock(s), clamps and filters, used as an external connection for invasive blood pressure measurement. This set will interface, either directly or from an interm...
A sterile length of flexible tube, with appropriate connectors at both ends, intended to connect an invasive blood pressure monitoring tubing set to a saline bag for flushing/priming of the arterial line. This is a single-use device.
A collection of devices that includes tubing, a pressure transducer(s), and other items [e.g., connectors, stopcock(s), clamps and filters] intended to be used for an invasive blood pressure measurement. This set will typically connect directly to the appli...
A noninvasive electronic device designed to convert air or gas pressure signals into electrical signals for subsequent display or processing by a parent device (e.g., physiological data recorder, gastrointestinal motility analysis system). It may be a compa...
An assembly of electronic devices designed to simultaneously monitor cerebrospinal fluid (CSF) pressure and drain CSF at a rate regulated by the desired intracranial or in-tube CSF pressure. It consists of a control unit, a user interface, and provides CSF ...
A mains electricity (AC-powered) device designed to measure the cerebrospinal fluid (CSF) pressure in a patient using an appropriate pressure/electrical transducer. It is an electronic instrument that connects with a dedicated CSF access device (catheter, c...
A noninvasive, electronic device intended to transcutaneously detect a patient's central venous pressure (CVP) using light emission/diffusion signals (e.g., near-infrared spectroscopy). It consists of a small photoelectric unit placed on the jugular vein ar...
A collection of sterile devices intended to be used in a multi-parameter urinary monitoring system to provide continuous urinary drainage with measured collection, and to detect intra-abdominal pressure (via intra-bladder pressure) and core temperature (via...
A small, sterile, non-powered device intended to be placed between external components of an invasive blood pressure monitoring tubing set (e.g., between intra-arterial line and transducer) to improve the accuracy of the pressure measurement. It is in the f...
A non-sterile respiratory device intended to facilitate gas sampling/monitoring by allowing an anaesthesia mask to be connected to a length of gas-sampling/monitoring respiratory tubing; the tubing (not included) is intended for subsequent connection to a r...
A collection of devices that includes the tubing and other items [e.g., connectors, stopcock(s), clamps and filters] intended to be used as an external connection for the invasive measurement of urethral and related urological pressures. This set will inter...
An electrically-powered device intended for intermittent or continuous measurement and display of intracranial pressure (ICP). It is used in conjunction with an invasive intracranial device (e.g., intracerebral sensor catheter) that transmits electrical sig...
An electrically-powered device intended for intermittent or continuous measurement and display of intracranial pressure (ICP). It is used in conjunction with an invasive intracranial device (e.g., intracerebral sensor catheter) that transmits electrical sig...
A mechanical device designed to be connected to another device or system of devices (e.g., rectal suction biopsy system) to provide an accurate indication of the amount of negative pressure being applied in these devices during a surgical intervention or ot...
A collection of sterile devices intended to electronically measure intra-abdominal pressure (IAP) through the bladder. It typically includes an electronic pressure transducer, syringe, tubing, connectors, and a urine collection bag. The assembled device is ...
A sterile length of flexible tube intended to interface a pressure monitor/manometer with a cardiopulmonary bypass system to allow fluid pressure to be measured; connectors are typically included. This is a single-use device.
A mains electricity (AC-powered) device used to electronically measure the pressure in a cardiopulmonary bypass system (e.g., in the extracorporeal tubing circuit); it may provide an alarm if pressure levels exceed operator-set limits. It is typically a mod...
A collection of noninvasive devices intended to be used to make connections in a multi-parameter urinary monitoring system during continuous urinary drainage with measured collection, and detection of intra-abdominal pressure (via intra-bladder pressure) an...
A collection of non-sterile devices intended to be integrated within a breathing circuit to enable interface of gases between the breathing circuit and a respiratory monitoring device for sampling the patient's expired gas for measurements of pressure, flow...
A two-way tubing with a stopcock designed to connect the proximal end of a cerebrospinal fluid (CSF) drainage catheter directly to a drainage bag or an intracranial pressure monitor via a Luer connection. It is typically made of polymer materials [e.g., pol...
A sterile, noninvasive cap intended to be connected to the Luer connector of non-vascular tubing (e.g., pressure monitoring) to close the lumen to prevent fluid path contamination. It is a small plastic device typically of Luer-lock design; it has no additi...
A device designed to connect to the vacuum terminal unit (wall outlet) of a vacuum pipeline system to control the degree of negative pressure (vacuum) provided by the system and applied in the evacuation of fluids, mucus or solids from the trachea. The devi...
A length of flexible noninvasive tube(s) primarily intended to be connected between a tube/mask breathing circuit connector and a respiratory gas measuring instrument [e.g., a carbon dioxide (CO2) or multi-gas analyser, manometer/pressure monitor] for gas p...