ishancare bed and pressure sore
ISHANCARE BED AND PRESSURE SORE
50 matching records for Pressure Sensor.
ISHANCARE BED AND PRESSURE SORE
TRIDERMA PRESSURE SORE RELIEF WOUND CLEANSER
DIPHENHYDRAMINE HCL, PHENYLEPHRINE HCL
ACETAMINOPHEN, GUAIFENESIN, PHENYLEPHRINE HCL
ACETAMINOPHEN, DEXTROMETHORPHAN HBR, GUAIFENESIN, PHENYLEPHRINE HCL
ACETAMINOPHEN, PHENYLEPHRINE HCL
OXYMETAZOLINE HCI
ACETAMINOPHEN, DEXTROMETHORPHAN HYDROBROMIDE, GUAIFENESIN, AND PHENYLEPHRINE HYDROCHLORIDE
ACETAMINOPHEN, DEXTROMETHORPHAN HYDROBROMIDE, GUAIFENESIN, AND PHENYLEPHRINE HYDROCHLORIDE
ACETAMINOPHEN, DEXTROMETHORPHAN HYDROBROMIDE, GUAIFENESIN, AND PHENYLEPHRINE HYDROCHLORIDE
ACETAMINOPHEN, GUAIFENESIN
ACETAMINOPHEN, DEXTROMETHORPHAN HYDROBROMIDE, GUAIFENESIN, AND PHENYLEPHRINE HYDROCHLORIDE
ACETAMINOPHEN, DEXTROMETHORPHAN HYDROBROMIDE, GUAIFENESIN, PHENYLEPHRINE HYDROCHLORIDE, TRIPROLIDINE HYDROCHLORIDE
ACETAMINOPHEN, DIPHENHYDRAMINE HCL, GUAIFENESIN, PHENYLEPHRINE HCL
ACETAMINOPHEN,DEXTROMETHROPHAN HBR
PHENYLEPHRINE HCL
ACETAMINOPHEN, DIPHENHYDRAMINE HCL, GUAIFENESIN, PHENYLEPHRINE HCL
ACETAMINOPHEN, PHENYLEPHRINE HCL
ACETAMINOPHEN, DEXTROMETHORPHAN HBR, GUAIFENESIN, PHENYLEPHRINE HCL
ACETAMINOPHEN AND PHENYLEPHRINE HYDROCHLORIDE
A hand-held, battery-powered device intended to be used by a healthcare professional in a clinical setting to enable manually-controlled powered inflation of a blood pressure cuff; it may also be intended to store pressure values. It consists of a compact u...
An electronic device intended to detect the plantar pressure distribution of a patient typically to help assess abnormal pressure and pressure asymmetries on the soles of the feet. It is a freestanding platform upon which the patient’s feet are placed for t...
A mains electricity (AC-powered) device, with a rechargeable battery, that is a component of a cerebrospinal fluid pressure regulation system designed to monitor/display cerebrospinal fluid (CSF) pressure, and to aspirate CSF at a rate regulated by CSF pres...
A sterile component of a cerebrospinal fluid pressure regulation system that consists of tubing and integrated mechanical pressure sensor designed to monitor cerebrospinal fluid (CSF) pressure to regulate drainage rate. It is intended to be taped to the pat...
An assembly of electronic devices intended to be used to measure the contact pressure between the body surface and a pressure-sensing pad to provide a map of compression forces during planning of/preparation for personal mobility device use or body support ...
A device intended to be incorporated into the distal end of a catheter (not included) to measure pressure. It typically consists of a pressure sensor (e.g., a flexible membrane or diaphragm) and a means to convert the detected pressure into electronic signa...
An assembly of devices designed to simultaneously monitor cerebrospinal fluid (CSF) pressure and aspirate CSF at a rate regulated by the desired intracranial or in-tube CSF pressure. It is connected to a dedicated CSF access device (e.g., catheter, needle) ...
An electronic device intended to generate a reference baseline for the standardization of readings of intracranial pressure (ICP) and/or pressure in a muscle compartment, and to transfer the readings from a catheter (i.e., intracerebral sensor or compartmen...
A small, wearable, electrically-powered device intended to be placed under a pressure bandage (typically during bandage application) for both initial and continuous measurement of sub-bandage pressure, to help facilitate optimal pressure therapy for disorde...
A mains electricity (AC-powered) assembly of electronic devices intended to be used to measure the actual pressure between an anatomical body surface and supporting media. Typically using an array of pressure sensors this system will provide a map of applie...
An external component of an ocular monitoring/recording system intended to enable continuous, wireless extraction of data from an implantable or nonimplantable ocular sensor (e.g., used to detect intraocular pressure (IOP) fluctuation in patients at risk of...
A fibreoptic cord designed for bidirectional transmission of light between a patient monitor and a sensor catheter (e.g., intracerebral sensor catheter). It is typically used for transmitting light used to measure intracerebral partial pressure of oxygen (p...
A battery-powered device intended to be worn against the sole of the foot to sense, measure, and transmit information regarding plantar pressure distribution for the biomechanical analysis of gait. It is typically a synthetic insole with integrated pressure...
An electrically-powered device intended for the continuous or intermittent measurement, display, and/or recording of several invasively-detected physiological parameters [e.g., blood pressure, intracranial pressure (ICP), temperature, and partial pressure o...
An electronic device intended to detect plantar pressure distribution and/or morphology to help assess abnormal pressure and/or structural deformities (e.g., flat foot, valgus toe) on the soles of the feet. It is a freestanding platform upon which the patie...
A noninvasive, electronic device intended to transcutaneously detect a patient's central venous pressure (CVP) using light emission/diffusion signals (e.g., near-infrared spectroscopy). It consists of a small photoelectric unit placed on the jugular vein ar...
A mobile, mains electricity (AC-powered) device designed to use laser Doppler techniques to measure the velocity of micro- and macrovascular blood circulation to assess of the extent of vascular flow restrictions [e.g., clots, stenosis, mechanical damage, a...
A device intended to be used with a transcutaneous blood gas monitor to measure a patient's blood partial pressure of oxygen (pO2), blood partial pressure of carbon dioxide (pCO2), and/or blood oxygen saturation transcutaneously (through the skin). Gases di...
A mains electricity (AC-powered) device designed for the continuous measurement and display of blood gas and related parameters when blood is circulated outside of the body in a closed system. It is typically used with an appropriate sensor or sensor casset...
A flexible tube with a sensor at the distal end intended to be surgically inserted through the skull for short-term (= 30 days) access to the ventricular and/or parenchymal areas of the brain to measure intracranial parameters [e.g., intracranial pressure (...
An assembly of devices intended for regular (e.g., daily) measurement and recording of pulmonary artery pressures, to assist monitoring and treatment of a heart disease patient at high-risk of heart failure. It includes a sensor intended to be implanted in ...
A sterile flexible tube with a sensor at the distal end intended to be surgically inserted through the skull for short-term (= 30 days) access to the ventricular and/or parenchymal areas of the brain to drain cerebrospinal fluid (CSF) and to measure intracr...
A flexible tube with a sensor at the distal end intended to be surgically inserted through the skull for short-term (= 30 days) access to the ventricular and/or parenchymal areas of the brain to measure intracranial parameters [e.g., intracranial pressure (...
A mains electricity (AC-powered) device designed for the continuous, transcutaneous (through the skin) measure of the partial pressure of oxygen (pO2) and the partial pressure of carbon dioxide (pCO2) in a paediatric patient's blood. It includes a special s...
A short, thin tube intended for short-term (
An electrically-powered device intended for intermittent or continuous measurement and display of intracranial pressure (ICP). It is used in conjunction with an invasive intracranial device (e.g., intracerebral sensor catheter) that transmits electrical sig...
A non-sterile flexible tube with electronic pressure sensors at the distal end intended to be inserted into the bladder via the urethra for measuring urethral/bladder pressure. Also known as a urodynamic solid-state sensor catheter, it is intended for proxi...
A flexible tube with a pressure sensor, transducer, and/or thermistor located at its distal tip, used for intrapartum transcervical measurement of the intrauterine and amniotic pressures. It is attached at its proximal end via a signal cable to an external ...
An electrically-powered device intended for intermittent or continuous measurement and display of intracranial pressure (ICP). It is used in conjunction with an invasive intracranial device (e.g., intracerebral sensor catheter) that transmits electrical sig...
A sterile flexible tube with electronic pressure sensors at the distal end intended to be inserted into the bladder via the urethra for measuring urethral/bladder pressure. Also known as a urodynamic solid-state sensor catheter, it is intended for proximal ...