Search

30 matching records for Probe unit.

GMDN Terms#

Otoacoustic emission system, battery-powered

113 GUDID devices

An assembly of battery-powered devices designed to record and analyse the faint sounds hair cells in the inner ear emit [otoacoustic emission (OAE)] in response to a stimulus (e.g., click, tone burst, pure-tone signals) to test for a deficiency of function ...

Otoacoustic emission system, line-powered

49 GUDID devices

An assembly of mains electricity (AC-powered) devices designed to record and analyse the faint sounds hair cells in the inner ear emit [otoacoustic emission (OAE)] in response to a stimulus (e.g., click, tone burst, pure-tone signals) to test for a deficien...

Foetal Doppler system

334 GUDID devices

A portable, hand-held, battery-powered device assembly consisting of a measuring and display unit and an attached probe or interchangeable probes designed to noninvasively detect foetal heart beats using ultrasound/Doppler technology. The heart beats are ty...

Pneumatic/ultrasonic lithotripsy system

38 GUDID devices

An assembly of devices that uses a combination of, or individually applied, pneumatically-created ballistic shock waves and ultrasonic waves for the intracorporeal fragmentation of stones (calculi) in the urinary tract (i.e., kidney, ureter, and bladder) fo...

Dermatological optical coherence tomography system

6 GUDID devices

An assembly of devices designed to use a broad-bandwidth light beam aimed via an applicator at a region of interest (ROI) on the surface of the skin for optical coherence tomography (OCT) to provide high-resolution images (e.g., above 1 micron) of the surfa...

Pneumatic lithotripsy system

4 GUDID devices

An assembly of devices (not all hand-held) designed to use pneumatically-created ballistic shock waves for the intracorporeal fragmentation of urinary tract calculi (stones) in the kidney, ureter, and bladder. It typically includes an electronic pressure re...

Dermatological optical coherence tomography system

3 GUDID devices

An assembly of devices designed to use a broad-bandwidth light beam aimed via an applicator at a region of interest (ROI) on the surface of the skin for optical coherence tomography (OCT) to provide high-resolution images (e.g., above 3 microns) of the surf...

Ultrasound imaging transducer positioning unit

2 GUDID devices

A unit used to position an ultrasound system imaging transducer that is inserted into the body through an endoscope. This device is an accessory to a diagnostic ultrasound imaging system and it transmits electrical signals that, after processing, will displ...

Pulse Co-oximeter probe, reusable

295 GUDID devices

A photoelectric component of a pulse Co-oximeter that is applied externally to a body part (e.g., a fingertip for adults, the hand or foot for neonates), for the transcutaneous multiwave measurement of carboxy-haemoglobin saturation (SpCO) and typically sev...

Pulse Co-oximeter probe, single-use

159 GUDID devices

A photoelectric component of a pulse Co-oximeter that is applied externally to a body part (e.g., a fingertip for adults, the hand or foot for neonates), for the transcutaneous multiwave measurement of carboxy-haemoglobin saturation (SpCO) and typically sev...

Pneumatic lithotripsy system handpiece

12 GUDID devices

A hand-held component of a pneumatic intracorporeal lithotripsy system designed to hold the system's ballistic probe (i.e., it forms a handle around the probe) and is connected via a dedicated cable to the system's control unit from which energy is transmit...

Endoscopic cryosurgical probe, single-use

9 GUDID devices

A flexible distal component of a cryosurgical system intended to be inserted through the working channel of an endoscope for cryoadhesion and devitalization of tissues during interventional procedures (e.g., bronchoscopy/interventional pulmonology). It is c...

Dermatological Raman spectroscopy system

7 GUDID devices

A mains electricity (AC-powered) device assembly intended to be used by a healthcare professional to non-invasively evaluate a skin lesion clinically suspicious for carcinoma (e.g., melanoma, squamous cell) and precursors, before making a decision to biopsy...

Cryosurgical system temperature probe

6 GUDID devices

A hand-held device intended to be used to monitor tissue temperature during a cryosurgical procedure, typically to measure the temperature in tissue adjacent to the ablated zone to assess extent of ablation and to limit ablation to protect local tissues. It...

Pneumatic/ultrasonic lithotripsy system control unit

6 GUDID devices

A mains electricity (AC-powered) component of a pneumatic/ultrasonic intracorporeal lithotripsy system designed to regulate the energy delivered to fragment the stones (i.e., renal, ureteral, urethral, and bladder calculi) for their removal. It is typically...

Arthroscopic shaver/electrosurgical system generator

2 GUDID devices

A mains electricity (AC-powered) device designed to provide energy for a system designed to perform arthroscopic shaving (i.e., abrasion, resection, debridement of bone and soft tissue with a blade) and electrosurgical diathermy (i.e., the ablation and coag...

Dissolved oxygen meter, battery-powered

2 GUDID devices

A hand-held, battery-powered instrument designed to measure the concentration of dissolved oxygen (DO) in solutions, typically in the field. It typically consists of an electronic unit that processes an electric signal from a sensor and displays oxygen conc...

Endoscopic cryosurgical probe

2 GUDID devices

A flexible distal component of a cryosurgical system intended to be inserted through the working channel of an endoscope for cryoadhesion and devitalization of tissues during bronchoscopy/interventional pulmonology. It is connected at the proximal end to th...

Dental caries detector, electrical impedance

1 GUDID devices

A mains electricity (AC-powered) device designed to measure resistance to the flow of electric current across teeth for the diagnosis of early stage dental caries and/or to monitor the progress of caries (carious areas being less resistant due to higher con...

Intraoperative parathyroid detection system probe

1 GUDID devices

A hand-held component of an intraoperative parathyroid detection system designed to aid surgeons in recognizing parathyroid tissue during open surgical thyroidectomies and parathyroidectomies using near-infrared (NIR) light and auto-fluorescence. The probe ...

Intraoperative parathyroid detection system probe

1 GUDID devices

A sterile hand-held component of an intraoperative parathyroid detection system designed to aid surgeons in recognizing parathyroid tissue during open surgical thyroidectomies and parathyroidectomies using near-infrared (NIR) light and auto-fluorescence. Th...

Intermittent electronic patient thermometer

1,307 GUDID devices

A hand-held, battery-powered, electronic instrument designed to measure a patient's body temperature. It may comprise an electronic unit with an attached probe or be a single unit (shaped like an ordinary hand-held capillary thermometer) that detects and co...

Electroencephalographic monitoring system

97 GUDID devices

An electrically-powered device assembly designed to continuously measure the electrical signals produced by a patient's brain and display/record them as an electroencephalogram (EEG) to evaluate brain function, typically in an examination room or intensive ...

Noninvasive vascular ultrasound system, line-powered

75 GUDID devices

A mains electricity (AC-powered) device assembly consisting of a desktop unit, a graphical display unit and an attached probe or interchangeable probes, designed to noninvasively locate and assess the extent of vascular flow restriction (e.g., clots, stenos...

Thermal-dilution cardiac output unit

51 GUDID devices

A unit that measures the blood flow from the heart using the indicator dilution technique, in which a thermal indicator (e.g., cold saline solution or other indicator solution) is injected upstream of the heart and monitored on the downstream side by a ball...

Electroencephalographic monitoring system, stationary

24 GUDID devices

A mains electricity (AC-powered) device assembly designed to continuously measure the electrical signals produced by a patient's brain and display/record them as an electroencephalogram (EEG) to evaluate brain function. It may be capable of monitoring vario...

Confocal endomicroscopy system

22 GUDID devices

An assembly of mains electricity-powered (AC-powered) devices designed to visualize microscopic cellular and tissue structures during an endoscopic, interventional or surgical procedure to provide real-time images to facilitate further treatment planning. I...

Electroencephalographic monitoring system, portable

20 GUDID devices

A mains electricity (AC-powered) device assembly designed to continuously measure the electrical signals produced by a patient's brain and display/record them as an electroencephalogram (EEG) to evaluate brain function. It may be capable of monitoring vario...