534 GUDID devices
A copy of a final reverse shoulder prosthesis cup designed to be used before primary or revision implant surgery to validate the proper size of the permanent prosthesis required by the patient and to ensure its proper orientation and positioning. It is inte...
245 GUDID devices
A copy of a final humeral body prosthesis designed to be used before primary or revision implant surgery to validate the proper size of the permanent prosthesis required by the patient and to ensure its proper orientation and positioning. It connects to a h...
191 GUDID devices
A sterile implantable tubular device designed to connect a femoral head prosthesis to the trunnion of a femoral stem prosthesis. It is typically intended to be used as part of a total hip arthroplasty (THA) revision to correct offset, neck length, lateraliz...
1,569 GUDID devices
A copy of a final humeral head prosthesis designed to be used before primary or revision implant surgery to validate the proper size of the permanent prosthesis required by the patient, to ensure its proper orientation and positioning, and to verify that th...
7 GUDID devices
A sterile copy of a final humeral head prosthesis designed to be used before primary or revision implant surgery to validate the proper size of the permanent prosthesis required by the patient, to ensure its proper orientation and positioning, and to verify...
123 GUDID devices
A copy of a final reverse shoulder prosthesis cup designed to be used before primary or revision implant surgery to validate the proper size of the permanent prosthesis required by the patient and to ensure its proper orientation and positioning. It connect...
846 GUDID devices
A sterile implantable artificial substitute for a diseased or injured humeral head. It is made of metal [e.g., titanium (Ti), cobalt-chrome (Co-Cr), stainless steel] and designed to be attached to a humeral stem prosthesis and to articulate with the natural...
373 GUDID devices
An implantable artificial substitute for a diseased or injured humeral head. It is made of metal [e.g., titanium (Ti), cobalt-chrome (Co-Cr), stainless steel] and designed to be attached to a humeral stem prosthesis and to articulate with the natural glenoi...
6 GUDID devices
An implantable device intended to be used as an attachment for a resurfacing humeral head prosthesis joint to treat a disease-damaged (e.g., arthritic) shoulder joint. It consists of a metallic peg [e.g., titanium (Ti), cobalt-chrome (Co-Cr), stainless stee...
62 GUDID devices
An implantable hemisphere-shaped device used as part of a total hip arthroplasty (THA) and designed to interface with the acetabular liner on its outer surface where it freely rotates, and encompass/interface with a femoral head prosthesis on its inner surf...
309 GUDID devices
A sterile implantable component of a total shoulder prosthesis intended to form a connection between a humeral stem prosthesis and a humeral head prosthesis. It is made of metal [e.g., cobalt-chrome-molybdenum (Co-Cr-Mo)] or titanium (Ti)] and is used in a ...
3,362 GUDID devices
A copy of a final femoral head prosthesis designed to be used for trial reductions during hip arthroplasty to judge the correct size, and to help achieve the desired offset, leg-length, and range of motion of the final prosthesis to be implanted. It is one ...
204 GUDID devices
A copy of a final reverse shoulder prosthesis head designed to be used before primary or revision implant surgery to validate the proper size of the permanent prosthesis required by the patient and to ensure its proper orientation and positioning. It is hem...
6 GUDID devices
A sterile implantable component of a total shoulder prosthesis intended to be used in the revision surgery of a reverse shoulder prosthesis to avoid replacement of the humeral body/stem by enabling articulation between a reverse shoulder body and a standard...
1,862 GUDID devices
An implantable artificial substitute for a diseased or injured femoral head that has an outer surface made of metal [e.g., cobalt-chrome (Co-Cr), titanium (Ti), stainless steel]. It is designed to be attached to the trunnion of a prosthetic femoral stem/sha...
873 GUDID devices
A sterile implantable artificial substitute for a diseased or injured femoral head that has an outer surface made of metal (e.g., titanium alloy). It is designed to be attached to the trunnion of a prosthetic femoral stem/shaft or a head/stem adaptor, and t...
735 GUDID devices
A sterile implantable artificial substitute for a diseased or injured femoral head that has an outer surface made of ceramic (e.g., alumina, zirconia). It is designed to be attached to the trunnion of a prosthetic femoral stem/shaft or a head/stem adaptor, ...
732 GUDID devices
An implantable artificial substitute for a diseased or injured femoral head that has an outer surface made of ceramic (e.g., alumina, zirconia). It is designed to be attached to the trunnion of a prosthetic femoral stem/shaft or a head/stem adaptor, and to ...
168 GUDID devices
A sterile, implantable, hemisphere-shaped component of a bipolar partial shoulder prosthesis designed to interface with the glenoid fossa on its outer surface where it freely rotates, and interface with a humeral head prosthesis on its inner surface where i...
28 GUDID devices
A sterile implantable artificial substitute for a diseased or injured humeral head. It is made of metal [e.g., titanium (Ti), cobalt-chrome (Co-Cr), stainless steel] and designed to be attached to a humeral metaphyseal anchor (a small metal framework that f...
20 GUDID devices
An implantable, hemisphere-shaped component of a bipolar partial shoulder prosthesis designed to interface with the glenoid fossa on its outer surface where it freely rotates, and interface with a humeral head prosthesis on its inner surface where it allows...
15 GUDID devices
A sterile implantable artificial substitute for the humeral component of a shoulder joint typically replaced due to injury (e.g., fracture). It includes humeral head and stem components and a humeral head bipolar component (device that articulates with the ...
10,778 GUDID devices
A sterile, implantable component of a two-piece acetabulum prosthesis that is inserted into an acetabular shell prosthesis to provide the articulating surface with a femoral head prosthesis as part of a total hip arthroplasty (THA). It is made of polyethyle...
4,836 GUDID devices
A copy of a final femoral stem prosthesis designed to be used for trial reductions during hip arthroplasty to judge the correct offset, leg-length, and range of motion of the final femoral prosthesis to be implanted. It is one of a set, or a set, of graduat...
1,444 GUDID devices
A sterile, implantable component of a two-piece acetabulum prosthesis that is inserted into an acetabular shell prosthesis to provide the articulating surface with a femoral head prosthesis as part of a total hip arthroplasty (THA). It is made of polyethyle...
1,163 GUDID devices
A sterile device designed to replace the entire femoral component of a total hip prosthesis implanted during replacement of the total hip prosthesis typically due to wear. The revision device is composed of two or more separate segments (e.g., femoral head,...
720 GUDID devices
A sterile component of a reverse shoulder prosthesis that consists of a polyethylene (PE) cup intended to be attached to a humeral stem prosthesis, or humeral body component, and to articulate with the reverse shoulder head.
418 GUDID devices
A sterile device designed to replace the entire femoral component of a total hip prosthesis implanted during replacement of the total hip prosthesis typically due to wear. The revision device is composed of two or more separate segments (e.g., femoral head,...
232 GUDID devices
A sterile component of a reverse shoulder prosthesis that consists of a metal plate [e.g., titanium (Ti), cobalt-chrome (Co-Cr), stainless steel] intended to be firmly attached to the scapula with screws. It is intended to serve as the foundation for the re...
144 GUDID devices
A sterile implantable device intended to help prevent dislocation of a total hip replacement by augmenting the posterior lip of the acetabulum around a retained acetabular prosthesis, or to help fill bone defects not covered by the acetabular prosthesis. It...