A dedicated battery-powered assembly of devices intended to be used to remove circular sections of the skull vault (calvarium) to provide access to the interior for diagnosis (e.g., the insertion of a neuroscope), or treatments [e.g., to alleviate intracran...
A noninvasive hand-held manual device designed to facilitate insertion, reinsertion, and/or removal of a dental power tool endpiece (e.g., oscillatory file/rasp, saw, or scalpel) into/from a power tool handpiece; it may in addition be used as a holder withi...
A surgical tool designed for overdrilling, gripping, and extracting an implanted surgical screw shaft when the screw head has become defective or detached, or the shaft has broken. It is in the form of a thin hollow metal shaft, with saw teeth at the cuttin...
A sterile surgical tool designed for overdrilling, gripping, and extracting an implanted surgical screw shaft when the screw head has become defective or detached, or the shaft has broken. It is in the form of a thin hollow metal shaft, with saw teeth at th...
A surgical tool designed for overdrilling, gripping, and extracting an implanted surgical screw shaft when the screw head has become defective or detached, or the shaft has broken. It is in the form of a thin hollow metal shaft, with saw teeth at the cuttin...
A mains electricity (AC-powered) device used for the removal of the skin surface by abrasion (applied by some kind of rotating abrasive tool, e.g., a wire brush or emery disc). It may be used during plastic surgery and can be used for treatments such as the...
A mains electricity (AC-powered) device used for the removal of the skin surface by abrasion (applied by some kind of rotating abrasive tool, e.g., a wire brush or emery disc). It may be used during plastic surgery and can be used for treatments such as the...
A device intended to be used during the release and removal of a cut implantable pacemaker or implantable cardioverter-defibrillator (ICD) lead, of the solid type (lumenless), from surrounding tissue during lead extraction. It is a sterile wire with a loop ...
A collection of surgical instruments and devices intended to be used for the implantation of a sacroiliac joint transarticular fixation/arthrodesis implant during a minimally-invasive procedure. It typically consists of a tray, dedicated soft-tissue protect...
A single- or double-lumen (coaxial) tube in a straight or spiral design intended to be used to conduct compressed surgical-grade air or nitrogen (N2) gas from a gas source, usually the central medical gas supply system, to a surgical drilling system or sawi...
A collection of non-sterile surgical instruments and devices intended to be used for the implantation of a sacroiliac joint transarticular fixation/arthrodesis implant during a minimally-invasive procedure. It typically consists of a tray, dedicated soft-ti...
A sterile endoscope with a flexible inserted portion intended for the visual examination and treatment of the bladder and the urinary tract by introduction through the urethra. Anatomical images are transmitted from a distal camera and displayed on a monito...
A small device intended to be used as a cover/cap for the external coil of a cochlear implant (CI) or auditory brainstem implant system, and/or to maintain the position of the coil casing. It is typically supplied with a removal tool. This is a reusable dev...
A device with wire bristles that is rotated in a power-driven tool to plane the skin (surgical removal of the epidermis and as much of the dermis as necessary) to remove scars, tattoos, pigmented nevi, fine wrinkles, or other irregularities. This is a reusa...
A surgical cutting device intended to be used with a cast removal tool (cast cutter) to provide the cutting edge for cutting through cast material so that this can be removed from the patient. It is formed as a thin, rounded, half moon-like, or circular bla...
A single or double lumen (coaxial) tube in a straight or spiral design used to conduct compressed surgical-grade air or nitrogen (N2) gas from a gas source, usually the central medical gas supply system, to a surgical drilling system or sawing system handpi...
A small device intended to be used as a cover/cap for a cochlear implant system coil, and/or to maintain the position of the coil casing. It is typically supplied with a removal tool. This is a reusable device.
A shaft of metal with a hollow centre designed for overdrilling a surgical screw or screw shaft to expose it for its removal, with another instrument, when the screw head has become defective or detached. The device is commonly called a "hollow mill" or "cr...
An endoscope with a flexible inserted portion intended for the visual examination and treatment of the bladder and the urinary tract by introduction through the urethra. Anatomical images are transmitted from a distal camera and displayed on a monitor. It i...
A surgical tool designed to over-drill a dental implant to facilitate its removal by excising bone in which it is implanted. It is in the form of a hollow fluted metal shaft, with saw teeth at the cutting edge, available in a variety of sizes to match diffe...
A surgical tool designed to over-drill a cylindrical orthopaedic implant (screw, pin, intrameduallry nail) to facilitate its removal by excising overgrown bone or other tissue. It is in the form of a hollow fluted metal shaft, with saw teeth at the cutting ...
A small device intended to be used as a cover/cap for the coil of a cochlear implant (CI) or auditory brainstem implant system, and/or to maintain the position of the coil casing. It is typically supplied with a removal tool. This is a reusable device.
A non-sterile shaft of metal with a hollow centre designed for overdrilling a surgical screw or screw shaft to expose it for its removal, with another instrument, when the screw head has become defective or detached. The device is commonly called a "hollow ...
"A shaft of metal with a hollow centre designed for overdrilling a surgical screw or screw shaft to expose it for its removal, with another instrument, when the screw head has become defective or detached. The device is commonly called a ""hollow mill"" or ...
A device that is a component of a medical gas pipeline system or a medical gas/vacuum pipeline system that has a gas-specific outlet connection for nitrogen (N2). It is designed to be mounted to wall-mounted medical supply units, utility supply systems (cei...
A single- or double-lumen (coaxial) tube in a straight or spiral design intended to be used to conduct compressed surgical-grade air or nitrogen (N2) gas from a gas source, usually the central medical gas supply system, to a surgical drilling system or sawi...
A device intended to connect the lumen of an appropriate surgical instrument, endoscope, and/or other cleaning tool, to the tubing of a device washer/decontaminator, or a tap, to facilitate an improved intraluminal flush and/or other cleaning of the instrum...
A single- or double-lumen (coaxial) tube in a straight or spiral design intended to be used to conduct compressed gas from a source to a dental drilling system handpiece to provide power to the turbine. The device is of an adequate length to provide manoeuv...
A sterile device intended to be used as a dedicated tool for the insertion and/or removal of a hypopharyngeal fistula occluder. It is in the form of a thin tube with a mechanism for attaching the occluder at the distal end so that it can be pulled into, or ...