81 GUDID devices
A hand-held device designed to be connected to a separate cannula/tip for both irrigation and aspiration of a surgical site by regulating and directing a stream of pressurized fluid (e.g., sterile water) to the site and facilitating suction of debris from t...
18 GUDID devices
A hand-held device designed to be used for both irrigation and aspiration of a surgical site by regulating and directing a stream of pressurized fluid (e.g., sterile water) to the site and facilitating suction of debris from the site. It is fitted with a lo...
21 GUDID devices
A sterile flexible container used to temporarily isolate a patient body part/organ during a surgical procedure, typically to segregate it from the surgical site. The device may be used to: 1) cover a dirty body part (e.g., hand/foot) to prevent cross-contam...
64 GUDID devices
An atraumatic, invasive, single-lumen, rigid/semi-rigid tube designed as a conduit for aspiration of body cavities, wounds, or surgical sites to facilitate observation and/or clear an airway obstruction, whilst providing illumination of the site. It is not ...
2,664 GUDID devices
A non-sterile, noninvasive flat sheet designed to cover a portion of a patient’s anatomy during a surgical procedure to isolate a specific anatomical site (e.g., site of surgical incision) from potential contamination (e.g., microbial, substance). The devic...
1,869 GUDID devices
A sterile, noninvasive flat sheet designed to cover a portion of a patient’s anatomy during a surgical procedure to isolate a specific anatomical site (e.g., site of surgical incision) from potential contamination (e.g., microbial, substance). The device ma...
112 GUDID devices
A surgically-invasive device designed to be attached to the distal end of a lavage system or kit handpiece to intraoperatively function as an applicator/nozzle that produces an intentional jet, stream or spray of sterile fluid (typically saline) from its ap...
86 GUDID devices
An assembly of devices using a remotely-controlled radioactive source transport system designed to deliver a therapeutic or palliative radiation dose from a single source or source train to an anatomical region by placing the radioactive source(s) temporari...
75 GUDID devices
A sterile, hand-operated device that is a component of a water jet knife system and designed to direct a concentrated stream of high-pressure water (typically sterile saline) to a surgical site to cut/dissect tissue. This handpiece is connected to a generat...
10 GUDID devices
A sterile electrical conductor comprised of an electrode handpiece with cables and an active electrode, intended to be used to cut and coagulate tissue at a surgical site. The electrode is typically non-detachable and provides an electrical connection betwe...
8 GUDID devices
An invasive luminal device intended to be inserted into the rectum and/or colostomy site for the administration of irrigation fluid into the rectum and/or large intestines during a rectal irrigation, colonic lavage, enema, and/or colostomy site irrigation p...
6 GUDID devices
A sterile, semi-flexible, hand-held surgical instrument designed to connect to a radio-frequency (RF) ablation system generator to deliver RF energy to a targeted operative site for soft-tissue ablation (i.e., thermal ablation, therapeutic lesion, or denerv...
347 GUDID devices
A non-dedicated metal wire designed to position a catheter or similar interventional device (e.g., a dilator or an endoscope) within a lumen of the gastrointestinal (GI) tract, the tracheobronchial tree, and the urinary tract (i.e., not dedicated to either ...
155 GUDID devices
A sterile, transparent, semi-permeable (i.e., impermeable to fluids, permeable to vapours and gases) covering applied to wounded or diseased tissue to provide protection (e.g., from dirt, water) and/or promote healing, and that contains an antimicrobial age...
85 GUDID devices
A sterile device designed to be attached to the distal end of a lavage system or kit handpiece to function as an applicator/nozzle that produces an intentional jet, stream or spray of sterile fluid (typically saline) from its aperture to the site of operati...
82 GUDID devices
A sterile device designed to temporarily channel (shunt) intravascular blood through a vascular anastomosis, primarily to control bleeding and enable distal perfusion during coronary or peripheral vascular bypass grafting and vessel repair surgery. It is ty...
75 GUDID devices
A sterile, sharp bevel-edged, hollow tubular metal instrument designed to percutaneously explant bone marrow (explant is the collection and transfer of living bone marrow from its natural site to a new site, or to a culture medium). The device is typically ...
70 GUDID devices
An electrically-powered, light-emitting device that includes a light source and is intended to be placed within, or nearly within, a surgical wound/site for illumination during open surgery. It may be fixed to a surgical instrument (e.g., a retractor) and t...
64 GUDID devices
A device designed to hold suture threads to facilitate their manipulation, positioning and differentiation around the operative site during a surgical procedure. It typically has a circular, oval, or curved shape with grooves or other connecting elements, a...
61 GUDID devices
A sterile device in the form of a flat, rectangular plate designed to support a skin graft (a section of donor skin from another part of a patient's body) while the graft is being perforated in a skin graft mesher in preparation for grafting to the treatmen...
54 GUDID devices
A collection of sterile, flexible, plastic tubing and associated items (e.g., connectors, line clamp, negative pressure applicator pad, canister) intended to be used as part of a vacuum-assisted wound closure system; commonly known as negative pressure woun...
21 GUDID devices
An atraumatic, invasive, single-lumen, rigid/semi-rigid tube designed as a conduit for aspiration of body cavities, wounds, or surgical sites to facilitate observation and/or clear an airway obstruction, whilst providing illumination of the site. It is not ...
13 GUDID devices
A dressing-like device intended to cover and protect an intravenous access site to manage and help prevent complications (e.g., leakage, bleeding, infection). It is available in a variety of designs which may include a foam pad intended to absorb exudates/b...
11 GUDID devices
An electrically-powered, light-emitting device that includes a light source and is intended to be placed within, or nearly within, a surgical wound/site for illumination during open surgery. It may be fixed to a surgical instrument (e.g., a retractor) and t...
8 GUDID devices
A collection of hand-operated instruments designed for the percutaneous delivery of sutures to close a femoral artery or vein puncture site following a catheterization procedure; it is intended to reduce the time to haemostasis and ambulation for the patien...
8 GUDID devices
A hand-held manual instrument intended to be orally introduced into the oesophagus during thoracic surgery to mechanically divert the oesophagus away from the site of surgery, to facilitate surgical site access and to help prevent injury. It is available in...
8 GUDID devices
A small, hand-held, manually-operated, sterile device designed to assist with the location of the subcutaneous injection port of an implanted tissue expander prior to the insertion of a filling needle into the port in order to fill the tissue expander with,...
7 GUDID devices
A sterile, transparent covering that is permeable to fluids intended to be applied to wounded or diseased tissue to provide protection (e.g., from dirt, microbes) and/or promote healing. It is a thin, clear, hydrophilic membrane made of synthetic polymer (e...
7 GUDID devices
A covering that is permeable to fluids intended to be applied to wounded or diseased tissue to provide protection (e.g., from dirt, microbes) and/or promote healing. It is a thin, clear, hydrophilic membrane made of synthetic polymer (e.g., polyurethane bas...
2 GUDID devices
A noninvasive, electronic component of an infiltration/extravasation monitoring system intended to emit and receive light to/from the skin surface and transmit electronic signals to the system monitor (not included), for the detection of a fluid leak into s...