A rigid, non-powered device designed to direct a sharp needle (not included) into its proper course when performing a clinical and/or surgical procedure; the guide itself is not intended for percutaneous access (not a guide-catheter). Dedicated needle guide...
A rigid, non-powered device designed to lead a needle (not included) into its proper course when performing a clinical and/or surgical procedure; the guide itself is not intended for percutaneous access (not a guide-catheter). Dedicated needle guides are av...
A rigid, non-powered device designed to lead a needle (not included) into its proper course when performing a clinical and/or surgical procedure; the guide itself is not intended for percutaneous access (not a guide-catheter). Dedicated needle guides are av...
A rigid, non-powered device designed to direct a sharp needle (not included) into its proper course when performing a clinical and/or surgical procedure; the guide itself is not intended for percutaneous access (not a guide-catheter). Dedicated needle guide...
A rigid, non-powered device designed to direct a sharp needle (not included) into its proper course when performing a clinical and/or surgical procedure; the guide itself is not intended for percutaneous access (not a guide-catheter). Dedicated needle guide...
A collection of sterile devices designed to drain small, superficial abscesses and/or fluid collections. It will typically include an introducer needle, a guidewire, and a flexible, single-lumen, micro-drainage catheter with attached dilator that allows for...
A sterile flexible tube designed to provide percutaneous access to a peripheral nerve group for the insertion of a nerve-block blunt needle and injection of an anaesthetic/analgesic agent for nerve-block/pain control. It is typically made of plastic and con...
A collection of sterile devices intended to be used during a needle entry procedure (e.g., central venous access, aspiration of pneumothorax) that combines ultrasonic and electromagnetic methods for needle guidance (e.g., needle depth data using Hall effect...
A collection of sterile devices intended to provide percutaneous access to a peripheral nerve group for injection of an anaesthetic/analgesic agent for nerve-block/pain control (e.g., sleeve blocks, deep muscle blocks, hypogastric blocks, paravertebral bloc...
A sharp bevel-edged, hollow tubular instrument designed for short-term use to withdraw a sample of cerebrospinal fluid (CSF), assist introduction of a spinal guidewire or catheter (e.g., lumboperitoneal shunt, intrathecal catheter), and/or deliver contrast ...
A sterile component of a resective skin contouring/liposuction system intended to connect the system handpiece to a single coring needle to function as a guide for the insertion depth of the needle. It is one of a set, or a set, of graduated sizes and provi...
A metal or plastic bracket intended to be applied to a hand-held ultrasound (US) transducer for the repeatable positioning (detach from/reattach to same place) of an electromagnetic (EM) sensor and/or needle guide on the transducer. It may be used in conjun...
A metal or plastic bracket manually applied to a hand-held ultrasound (US) transducer intended to provide a means to attach/hold an electromagnetic (EM) sensor or needle guide to the distal end of the US transducer in a repeatable position (can detach/reatt...
A collection of sterile devices used to assist in the placement of an endotracheal (ET) tube during difficult/emergency airway access procedures. The device typically consists of a guidewire, needles, and a needle holder made of metal, and catheters and ada...
A collection of sterile devices which includes a portosystemic needle intended to create an artificial passage between the hepatic and portal veins (through the liver parenchyma) as part of a transjugular intrahepatic portosystemic shunt (TIPS) procedure. I...
A flexible tube intended to be used for the percutaneous transluminal passage and placement of a diagnostic/interventional catheter, lead (e.g., pacing lead, balloon dilatation catheter), needle or guidewire through its lumen(s), within the vascular system....
A sterile, sharp bevel-edged, hollow tubular metal instrument used for in vitro fertilization (IVF), gamete intrafallopian transfer (GIFT), or other assisted reproduction procedures to obtain gametes from the body or introduce gametes, zygote(s), preembryo(...
A sterile, sharp bevel-edged, hollow tubular metal instrument used for in vitro fertilization (IVF), gamete intrafallopian transfer (GIFT), or other assisted reproduction procedures to obtain gametes from the body or introduce gametes, zygote(s), preembryo(...
A collection of various instruments/devices (e.g., introducer sheath, dilator, guides, cannula, needle, angiographic catheter) intended to be used for percutaneous body-access to facilitate a radiological image-guided interventional radiology or surgical pr...
A slender, straight hollow instrument, usually with a sharp bevelled end, designed to be used with a syringe for the transient delivery of fluid materials (e.g., anaesthetic agents, therapeutic drugs) to various structures in and around the eye, including t...
A sterile hand-held component of an ultrasound-guided intrauterine electrosurgical system consisting of both a handpiece and a monopolar electrode designed to provide an electrical connection between the output terminals of a dedicated electrosurgical gener...
A sharp bevel-edged, hollow tubular metal instrument designed to make the initial percutaneous puncture to access a vein and/or artery during vascular catheterization. It is available in a variety of forms to enable a catheter to be introduced directly, or ...
A collection of sterile devices that includes a biopsy needle and other supplies used to perform an ultrasound-guided aspiration sampling of tissue. The needle tip must provide a clearly visible image during ultrasound imaging. This is a single-use device.
A sterile, sharp bevel-edged, hollow tubular metal instrument designed to make the initial percutaneous puncture to access the kidney during nephrostomy catheter introduction for urinary drainage. It is intended to enable introduction of a guidewire (Seldin...
A luminal, one-piece, electrosurgical device designed to be used with a transseptal vascular guide-catheter (not included) to penetrate the interatrial septum for left-heart access during a transseptal catheterization procedure. It is typically a long, thin...
A cap intended to be placed over the gloved, non-dominant index finger of a surgical staff hand to provide protection from blood contamination and to reduce accidental needle-sticks and scalpel cuts during a surgical procedure. It is a tough, thimble-like s...
A sterile, flexible tube intended to be used for the percutaneous transluminal passage and placement of a diagnostic/interventional catheter, lead (e.g., pacing lead, balloon dilatation catheter), or guidewire through its lumen(s), within the vascular syste...
A flexible tube intended to be used for the percutaneous transluminal passage and placement of a diagnostic/interventional catheter, lead (e.g., pacing lead, balloon dilatation catheter), or guidewire through its lumen(s), within the vascular system. It may...
A sterile, remote-afterloading brachytherapy applicator specifically designed for use in radiation therapy treatments of the breast. It is typically designed for temporary implantation within the breast and serves as a guide for computer-controlled placemen...
A collection of sterile, invasive devices intended to provide percutaneous vascular access to enable introduction of a cardiac device/catheter (e.g., cardiac ablation catheter, pacing lead); it is not intended for sub-xiphoid access. It includes a steerable...