A hand-held component of an ultrasonic surgical system which includes a holder with controls and a surgical endpiece (tip) intended to be connected to a system transducer (not included) whereby the tip oscillates (vibrates) at high frequency in order to fra...
A hand-held component of an ultrasonic surgical system which includes a holder with controls and a surgical endpiece (tip) intended to be connected to a system transducer (not included) whereby the tip oscillates (vibrates) at high frequency in order to fra...
A patient-contact dilating/measuring component of an endoscopic soft-tissue release system intended to be used for minimally-invasive transection of soft connective tissue (e.g., fascia, tendon) under direct vision. It consists of a probe-like device that i...
A sterile, hand-held component of an ultrasonic surgical system which includes a holder with controls and a surgical endpiece (tip) intended to be connected to a system transducer (not included) whereby the tip oscillates (vibrates) at high frequency in ord...
A patient-contact cutting component of an endoscopic soft-tissue release system intended to be used for minimally- invasive transection of soft connective tissue (e.g., fascia, tendon) under direct vision. It consists of a blade within a fenestrated tube th...
A non-powered hand-held component of an endoscopic soft-tissue release system intended to be used for minimally-invasive transection of soft connective tissue (e.g., fascia, tendon) under direct vision. It consists of a pistol-grip handpiece that provides h...
A hand-held component of an ultrasonic surgical system which includes a holder with controls and a surgical endpiece (tip) intended to be connected to a system transducer (not included) whereby the tip oscillates (vibrates) at high frequency in order to fra...
A sterile, hand-held component of an ultrasonic surgical system which includes a holder with controls and a surgical endpiece (tip) intended to be connected to a system transducer (not included) whereby the tip oscillates (vibrates) at high frequency in ord...
An assembly of electrically-powered devices designed to apply multiple different energies (e.g., light-energy, ultrasound, radio-frequency electrical stimulation, and microcurrent electrotherapy) either alone or in sequence, but not simultaneously, to nonin...
An underlay intended to produce heat through chemical reaction typically used to warm and/or maintain the body temperature of neonates or infants. It is typically designed with a soft outer casing (e.g., a soft plastic) that contains a chemically-reactive g...
An assembly of electrically-powered devices designed for professional use to apply multiple different energies (e.g., light-energy, ultrasound, radio-frequency electrical stimulation, electrotherapy) either alone or in sequence, but not simultaneously, to n...
A hand-held component of an ultrasonic surgical system intended to convert high frequency electrical current into an ultrasonic oscillation, and transfer the energy to an attachable tip, to mechanically fragment and cut both bone and soft-tissue cells upon ...
A mobile, mains electricity (AC-powered) assembly of devices designed to apply multiple different energies (e.g., light-energy, ultrasound, radio-frequency electrical stimulation, and microcurrent electrotherapy) either alone or in sequence, but not simulta...
A mobile assembly of electrically-powered devices intended for imaging and analysis of soft-tissue and soft-tissue vasculature using combined optoacoustic (photoacoustic) and ultrasound (US) imaging. It includes a processing unit with a monitor, controls, a...
An assembly of devices designed to produce and noninvasively transmit radio-frequency (RF) electromagnetic (EM) energy for localized treatment of a variety of soft-tissue, neuromuscular, and musculoskeletal injuries/disorders (e.g., joint pain/inflammation,...
An assembly of electrically-powered devices designed for professional use to apply multiple different energies (e.g., light-energy, ultrasound, radio-frequency electrical stimulation, electrotherapy) either alone or in sequence, but not simultaneously, to n...
A non-sterile component of an ultrasonic surgical system intended to convert high frequency electrical current from a generator into an ultrasonic oscillation at its distal tip to mechanically fragment soft-tissue cells upon contact for cutting and/or coagu...
A collection of surgical instruments and devices intended to be used for the implantation of a sacroiliac joint transarticular fixation/arthrodesis implant during a minimally-invasive procedure. It typically consists of a tray, dedicated soft-tissue protect...
A collection of non-sterile surgical instruments and devices intended to be used for the implantation of a sacroiliac joint transarticular fixation/arthrodesis implant during a minimally-invasive procedure. It typically consists of a tray, dedicated soft-ti...
An assembly of noninvasive devices intended for use during soft-tissue lesion treatment by ultrasound-guided laser thermal therapy, to provide software-based simulation of tissue thermal damage for assisting the manual positioning of percutaneous needles th...
A sterile, single-strand (monofilament), non-bioabsorbable wire made of metal (e.g., surgical steel, titanium, tantalum) intended to join (approximate) the edges of a soft-tissue wound or incision by stitching (e.g., for abdominal wound closure, intestinal ...
A single-strand (monofilament), non-bioabsorbable wire made of metal (e.g., surgical steel, titanium) intended to join (approximate) the edges of a soft-tissue wound or incision by stitching (e.g., for abdominal wound closure, intestinal anastomosis, hernia...
A non-bioabsorbable tubular device intended to be implanted into the trachea and/or a bronchus/bronchiole to maintain luminal patency, typically used in cases of obstructions/stenoses, fistulae, tumours, scarring, surgical resection and anastomosis, or pulm...
A sterile non-bioabsorbable tubular device intended to be implanted into the trachea and/or a bronchus/bronchiole to maintain luminal patency, typically used in cases of obstructions/stenoses, fistulae, tumours, scarring, surgical resection and anastomosis,...
A sterile, hand-held, invasive, ophthalmic surgical instrument intended to handle fluids and gases during vitreoretinal surgery. It is used for controlling the extraction of fluids, the internal drainage of subretinal fluid, retinal fold manipulation [proli...
A lifting device used together with a patient lifting system to provide a support for an incapacitated patient or a person with a disability that is being lifted in a lying (horizontal) position for transfer and (re)positioning. It is designed as an elongat...
An assembly of electrically-powered devices designed to treat solid tumours of hard (bone) and/or soft tissue [e.g., liver, kidney, breast, prostate] and/or gynaecological disorders (e.g., uterine fibroid, adenomyosis) through noninvasive or non-surgically ...
An assembly of devices designed to produce and deliver ultrasonic waves that penetrate tissues and produce both thermal and nonthermal (e.g., mechanical and cavitation) effects to treat pain (e.g., muscle, tendon, joint) and as an aid in the healing of soft...
A device designed to position and immobilize parts of the patient (e.g., head, extremities) typically during therapeutic interventions or patient transportation. The device immobilizes a body part by encompassing it and then applying a vacuum. The device is...