A sterile, powered, rotational, cutting device designed for use in an arthroscopic shaver system handpiece for soft and bone tissue resection during arthroscopic surgery on a joint, e.g., a knee, shoulder, or ankle. It is locked into a handpiece, and typica...
A sterile, powered, rotational, cutting device designed for use in an arthroscopic shaver system handpiece for soft and bone tissue resection during arthroscopic surgery on a joint, e.g., a knee, shoulder, or ankle. It is locked into a handpiece, and typica...
A powered, rotational, cutting device designed for use in an arthroscopic shaver system handpiece for soft and bone tissue resection during arthroscopic surgery on a joint, e.g., a knee, shoulder, or ankle. It is locked into a handpiece, and typically consi...
A sterile, multi-purpose electrical conductor inserted beneath the dermal layer of a patient's skin to record/monitor electrical activity (biopotentials) for physiological measurements [typically electroencephalography (EEG), electromyography (EMG), and evo...
A hand-held manual surgical instrument designed to identify the position and/or shape of bone structures and/or cavities created within these structures, e.g., the angle of a drilled hole, during surgery. It is typically designed as a long, thin, shaft with...
A cutting device designed for use in a powered arthroscopic shaver system handpiece (not included) for bone and soft-tissue resection during arthroscopic surgery on a joint (e.g., a knee, shoulder, or ankle). It is locked into the handpiece, and typically c...
A cutting device designed for use in a powered arthroscopic shaver system handpiece (not included) for bone and soft-tissue resection during arthroscopic surgery on a joint (e.g., a knee, shoulder, or ankle). It is locked into the handpiece, and typically c...
A thin, sterile, semi-rigid or rigid metal tube intended to be inserted percutaneously for the injection of a substance into the cutaneous or subcutaneous layers. It is typically used for the administration of fillers [e.g., hyaluronic acid (HA)] to add vol...
A hand-held manual surgical instrument designed to help position a fractured fragment of bone to achieve proper alignment (reduction). It is typically a long, thin, rigid rod made of high-grade stainless steel with a self-drilling/self-tapping screw thread ...
A cutting device designed for use in a powered arthroscopic shaver system handpiece (not included) for bone and soft-tissue resection during arthroscopic surgery on a joint (e.g., a knee, shoulder, or ankle). It is locked into the handpiece, and typically c...
A rod with a screw-like or press-fit design intended to be implanted into the residual bone of a lower limb (e.g., femur, tibia) after amputation to function as an anchoring fixture and stabilizing bar for the connection of an internal-external leg prosthes...
A powered, cutting device designed for use in an arthroscopic shaver system handpiece (not included) for bone and soft-tissue resection during arthroscopic surgery on a joint (e.g., a knee, shoulder, or ankle). It is locked into the handpiece, and typically...
A powered, cutting device designed for use in an arthroscopic shaver system handpiece (not included) for bone and soft-tissue resection during arthroscopic surgery on a joint (e.g., a knee, shoulder, or ankle). It is locked into the handpiece, and typically...
A collection of devices used to facilitate the implantation of a ureteral stent, via the natural orifice or percutaneously through a tortuous ureter, in order to maintain ureteral patency. The devices are typically made of high-grade stainless steel and/or ...
A hand-held manual surgical instrument designed to help position a fractured fragment of bone to achieve proper alignment (reduction). It is typically a long, thin, rigid rod made of high-grade stainless steel with a self-drilling/self-tapping screw thread ...
A powered, cutting device designed for use in an arthroscopic shaver system handpiece (not included) for bone and soft-tissue resection during arthroscopic surgery on a joint (e.g., a knee, shoulder, or ankle). It is locked into the handpiece, and typically...
A device used to seal the unused connector port of an implantable pacemaker or an implantable cardioverter-defibrillator (ICD), to provide electrical isolation and protect the parent device from the extremely hostile environment of the human body when impla...
A long, thin, sterile wire designed to provide the necessary length to allow the exchange of a catheter, or other interventional device, while maintaining the intravascular position of the catheter guidewire during an interventional procedure in the periphe...
A non-sterile, hand-held manual surgical instrument designed to help position a fractured fragment of bone to achieve proper alignment (reduction). It is typically a long, thin, rigid rod made of high-grade stainless steel with a self-drilling/self-tapping ...
A surgical instrument typically used in pairs to facilitate correct cranial orientation of craniofacial implants (e.g., fixation plates being attached to jaw bones) and other devices (e.g., craniofacial distractors) during their application in craniofacial ...
A cutting device designed for use in a powered spinal decompression shaver system handpiece (not included) for bone and soft-tissue resection during spinal surgery. It is locked into the handpiece and typically consists of a small outer tube with a hub and ...
A hand-held component of a pneumatic intracorporeal lithotripsy system designed to hold the system's ballistic probe (i.e., it forms a handle around the probe) and is connected via a dedicated cable to the system's control unit from which energy is transmit...
A sterile, hand-held manual surgical instrument designed to help position a fractured fragment of bone to achieve proper alignment (reduction). It is typically a long, thin, rigid rod made of high-grade stainless steel with a self-drilling/self-tapping scre...
A thin, sterile, semi-rigid or rigid metal tube that is inserted into the nipple of the female breast to inject a contrast medium into the lactiferous ducts to enhance their visualization during a radiographic procedure. It is typically made of high-grade s...
An assembly of sterile devices designed to create an opening between a blood vessel and a vascular graft (native or synthetic) during a vascular surgical procedure [e.g., coronary artery bypass grafting (CABG), or arteriovenous fistula (AVF) grafting]. It t...
A collection of sterile devices designed to repair an inflatable gastric band that deflates due to a leakage around the original connector or in the original tubing. It typically includes replacement silicone tubing, stainless steel connectors, a priming ne...
A sterile device designed to secure the attached pacing lead terminal(s) in the header connector (connection socket) of an implantable pacing device (e.g., an implanted pacemaker or defibrillator) during the implantation procedure. It is typically made of h...
An implantable device used to seal the unused connector port of an implantable pacemaker or an implantable cardioverter-defibrillator (ICD), to provide electrical isolation and protect the parent device. It is typically made of high-grade stainless steel an...
A vessel designed to protect the part of a device that cannot be exposed to liquid cleaning agents or disinfectant [e.g., the electrical connector of a transoesophageal echocardiography (TOE) probe] in a water-tight vault that may be air-pressurized, so the...