An electrically-powered device assembly intended to apply various modes of electrical stimulation transcutaneously to treat/prevent neuromuscular symptoms and disorders typically as a form of physical therapy [neuromuscular electrical stimulation (NMES)/ele...
An electrically-powered unit intended to apply various modes of electrical stimulation transcutaneously to treat/prevent neuromuscular symptoms and disorders typically as a form of physical therapy [neuromuscular electrical stimulation (NMES)/electronic mus...
An electrically-powered unit intended to apply various modes of electrical stimulation transcutaneously to treat/prevent neuromuscular symptoms and disorders typically as a form of physical therapy [neuromuscular electrical stimulation (NMES)/electronic mus...
An electrically-powered unit intended to apply various modes of electrical stimulation transcutaneously to treat/prevent neuromuscular symptoms and disorders typically as a form of physical therapy [neuromuscular electrical stimulation (NMES)/electronic mus...
An assembly of mains electricity (AC-powered) devices used to apply various modes of electrical stimulation transcutaneously to treat/prevent neuromuscular symptoms and disorders typically as a form of physical therapy. It typically includes an electric cur...
An assembly of mains electricity (AC-powered) devices used to apply various modes of electrical stimulation transcutaneously to treat/prevent neuromuscular symptoms and disorders typically as a form of physical therapy. It typically includes an electric cur...
An assembly of battery-powered devices used to apply various modes of electrical stimulation transcutaneously to treat/prevent neuromuscular symptoms and disorders typically as a form of physical therapy. It typically includes an electric current pulse gene...
A portable, external, electrically-powered component of a spinal cord/peripheral nerve implantable analgesic electrical stimulation system intended to be used by a patient to telemetrically control its function (on/off) for delivery of treatment cycles. The...
A portable, electrically-powered component of a spinal cord/peripheral nerve implantable analgesic electrical stimulation system intended to be used by a healthcare professional to program the pulse generator component with patient-specific parameters; a te...
A line-powered, external device intended to change, noninvasively, one or more of the operating parameters (the programs) of an implanted incontinence-control electrical stimulation system pulse generator. It is designed to read stored parameters in the imp...
A portable, battery-powered electronic component of an implantable lumbar neuromuscular electrical stimulation system intended to be used by a patient to telemetrically control its function (on/off) and delivery of treatment cycles. The system is designed t...
A portable, battery-powered electronic component of an implantable lumbar neuromuscular electrical stimulation system intended to be used by a healthcare professional to telemetrically program the implantable pulse generator component with patient-specific ...
A device intended to be used to change, noninvasively, one or more of the operating parameters (the programs) of an implanted stimulator used for vagus nerve stimulation (VNS). It is able to read stored parameters in the implanted device, providing historic...
A sterile implantable component of a video-camera epiretinal prosthesis system designed to be implanted around and inside the eye for neural stimulation of the retina via an electrode array that is attached to the retina with a retinal tack. It consists of ...
A sterile, implantable, conductive wire component of an implantable lumbar neuromuscular electrical stimulation system intended to deliver episodic electrical stimulation to nerves that innervate lumbar muscles, to elicit contraction for the treatment of ch...
An arrangement of multiple electrical conductors, designed as a component of a balance therapy translingual electrical stimulation system, intended to be placed on the tongue surface to apply electrical impulses during physical therapy for balance/gait reha...
A sterile, implantable, electronic component of an implantable lumbar neuromuscular electrical stimulation system intended to deliver episodic electrical stimulation to nerves that innervate lumbar muscles to elicit contraction for the treatment of chronic ...
A small, battery-powered, ingestible component of an internal gastrointestinal vibratory-stimulation system intended to be introduced into the gastrointestinal (GI) tract via the oral cavity to produce mechanical vibrations for stimulation of peristalsis an...
A noninvasive electrically-insulated wire intended to enable an electrical connection between an external pulse generator (EPG) of a [trial] implantable electrical stimulation system (e.g., intramuscular diaphragm/phrenic nerve or a spinal/peripheral nerve ...
An assembly of electrically-powered devices designed to reduce the perception of pain by electrically stimulating peripheral nerves across the skin [transcutaneous electrical nerve stimulation (TENS)]. It includes an external current generator and skin-surf...
A non-sterile, insulated, electrical conducting wire intended to be used to connect a transcutaneous electrical stimulation electrode to an electrical stimulus generator (e.g., TENS system generator), or a wire having a distal end that splits and terminates...
An assembly of electrically-powered devices intended for the treatment and/or diagnosis of neurological, psychiatric and/or cognitive conditions (e.g., Alzheimer's disease, major depressive disorder, pain) through noninvasive magnetic stimulation of the bra...
A stationary assembly of mains electricity (AC-powered) devices intended for the treatment of neurological, psychiatric and/or cognitive conditions (e.g., Alzheimer's disease, major depressive disorder, pain) through noninvasive magnetic stimulation of the ...
A mobile (on wheels) assembly of mains electricity (AC-powered) devices intended for the treatment and/or diagnosis of neurological, psychiatric and/or cognitive conditions (e.g., Alzheimer's disease, major depressive disorder, pain) through noninvasive mag...
An assembly of implantable devices intended for home management of obstructive sleep apnoea (OSA) by improving airway patency through stimulation of the hypoglossal nerve [targeted hypoglossal nerve stimulation (THN)], synchronous with respiration during sl...
An assembly of electronic devices intended to electrically stimulate the tongue during physical therapy to help rehabilitate body balance, and sometimes gait. The device may: 1) provide biofeedback for training of balance by sensing body movements and produ...
An assembly of electrically-powered devices intended to be used as a non-therapeutic control device (placebo) during clinical investigation trials of magnetic neural stimulation systems. It consists of a device assembly which resembles a magnetic neural sti...
A noninvasive assembly of mains electricity (AC-powered) devices, which may include a rechargeable battery, designed to apply weak continuous (not pulsed) electrical current (typically up to 2 mA) across the skin to a patients brain as a therapy for one or ...
A noninvasive assembly of electrically-powered devices designed to apply weak continuous (not pulsed) electrical current (typically up to 2 mA) across the skin to a patient's brain as a therapy for one or more psychiatric/neurological indications such as de...
A component of a retinal prosthesis system designed to perform diagnostic tests of the system, measure patient response to stimulation, and configure the system stimulation parameters and video processing strategies for each patient. It consists of laptop c...