A combination device for dental applications that consists of a cassette (barrier envelope) used to hold and shield an attached phosphor storage screen [mounted on a phosphor storage plate (PSP)] from exposure to room light during transport and insertion in...
A combination device for medical imaging applications that consists of a cassette used to hold and shield an attached storage phosphor screen from exposure to room light during transport and insertion into a diagnostic imaging x-ray system, and a computed r...
A combination device for mammography applications that consists of a cassette used to hold and shield an attached storage phosphor screen from exposure to room light during transport and insertion into a diagnostic mammography x-ray system, and a computed r...
A durable, sterile plastic container with ports, or glass bottle, intended for the storage and/or culture of tissue, cells, blood or blood components (e.g., peripheral blood stem cells) typically for subsequent therapeutic applications. The device provides ...
An assembly of devices designed to electronically transmit digitized radiology images, e.g., magnetic resonance imaging (MRI), x-ray, nuclear medicine, ultrasound, endosocopy or CT, and consultative text to one or more remote sites (teleradiology). The info...
A mobile, mains electricity (AC-powered) assembly of devices intended to prepare, bag, label and register disinfected and sterilized endoscopes prior to long-term storage. It typically includes: 1) a fluid preparation assembly such as fluid pump, tubing and...
A device intended to be fixed vertically within a clinical setting (e.g., healthcare facility wall, ambulance, trolley) to enable easy and secure short-term and/or long-term mounting of a portable electromechanical system (e.g., emergency suction system) du...
A mains electricity (AC-powered) device, typically a component of a picture archiving and communication system (PACS), used for the storage and retrieval of digital radiological images and information about the images. Its integral software functions as a d...
A mains electricity (AC-powered) freezer designed for the storage of laboratory products and sample materials, e.g., in vitro diagnostic (IVD) reagents and laboratory tissue/body fluid samples that require extremely low temperatures, usually in the range fr...
A device intended to be fixed within a clinical setting (e.g., healthcare facility wall, ambulance, trolley) to enable easy and secure short-term and/or long-term mounting of a portable active medical device (e.g., an electronic/electromechanical device suc...
A mains electricity (AC-powered) freezer designed for the storage of laboratory products, samples, test materials, chemicals or reagents that require low temperatures, usually in the range from -10? to -55? Celsius. It will typically have a corrosion resist...
A device intended to be fixed (e.g., to a healthcare facility wall, ambulance, trolley, floor) to enable easy and secure short-term and/or long-term mounting of a portable active medical device (e.g., an electronic/electromechanical device such as a barcode...
A mains electricity (AC-powered) device designed to provide suitable cold storage conditions for reproductive biological materials (e.g., gametes, embryos) at closely regulated and monitored temperatures. It will typically use liquid nitrogen (LN2) to creat...
A tube or hose-like catheter with connectors at both ends used to interface the brachytherapy applicator to the remote afterloading system. The transfer tube, when attached to the applicator and the afterloading system, provides a continuous closed passage ...
An assembly of optical and computer-based devices that use a broad-bandwidth light beam for optical coherence tomography (OCT) to provide high-resolution images (e.g., 5 to 40 microns) of the coronary intravasculature. It typically consists of a main operat...
An application software program, routines, and/or algorithms intended to be used in an operating room audiovisual data/device management system to enable the system to function according to its intended purpose. The software typically supports remote contro...
A non-sterile, noninvasive component of a cardiac mapping system intended to be worn on the torso to transmit cardiac bioelectric signals to the system for storage, analysis and display of cardiac electrophysiological data. It is typically in the form of a ...
A stationary assembly of mains electricity (AC-powered) devices designed to concentrate oxygen (O2) from ambient air and then deliver the concentrated O2, with purity of up to 99.5%, to the hospital medical gas supply system. It may produce high-purity O2 u...
A battery-powered external device used by a healthcare professional to change, telemetrically, one or more of the operating parameters (the programs) of an intramuscular diaphragm/phrenic nerve electrical stimulation system external pulse generator (EPG). I...
An electronic device (e.g., an optical reader) that automatically and continuously measures a patient's urine output (urine flow/volume) in a urine monitoring system's collection container. The sensor subsequently transmits urine output data, via a cable, t...
An individual software application intended to be installed on a central server as part of a picture archiving and communication system (PACS) to allow storage, retrieval, analysis, and management of radiological images. It is designed specifically for use ...
An assembly of devices intended to supply large-scale haemodialysis dialysate (concentrate and/or ready-to-use solution) to medical facility haemodialysis systems for preparation/mixing and/or direct use. The system is typically built into the facility and ...
A sterile collection of devices intended to be used in a blood cell processing system to either prepare red blood cells for frozen storage (glycerolization), or deglycerolize and wash red blood cells after thawing (may also wash fresh red blood cells). The ...
A portable, hand-held, electronic component of a gastrointestinal telemetric monitoring system designed to continuously and wirelessly receive electrical signals of gastrointestinal parameters (e.g., pH, pressure, temperature) or events (e.g., gastrointesti...
A computer-based image storage and retrieval picture archiving and communication system (PACS) that together with a connected electronic dermatoscope, captures, stores, recalls, and supports dermatological analyses/diagnoses through preselected digital imag...
A non-sterile radiation-shielding plastic box intended to store a manual-afterloading brachytherapy system. It is typically temporarily used as a safety container to prevent radiation leakage in the event of procedural difficulties.
A battery-powered component of a gastrointestinal telemetric monitoring system designed to be worn by a patient to continuously and wirelessly receive electrical signals of gastrointestinal parameters (e.g., pH, pressure, temperature) or events (e.g., gastr...
A non-sterile portable plastic container designed to store and transport a manual-afterloading brachytherapy system source transfer device. It includes accessory devices such as a flashlight, radioactive source recovery probe, magnifying glass, and tweezers...
A container intended to provide a suitable platform for containing many medical/surgical instruments and related items during a clinical procedure; it might in addition be used during reprocessing/sterilization procedures, however it is not dedicated to rep...
A container intended to provide a suitable platform for placing/containing many medical/surgical instruments and related items during a clinical procedure; it might in addition be used during, but not dedicated to, reprocessing/sterilization procedures. It ...