A sterile length of tube with valves intended to create a closed three-way connection between an endotracheal tube, a ventilator/anaesthesia unit, and a suction pump to eliminate the need to disconnect the breathing circuit for secretion suctioning. The val...
A noninvasive device designed to provide multiple connections for the various tubes used during peritoneal dialysis (patient, dialysate, waste) so that the patient or healthcare provider can conveniently switch the connection between different tubes during ...
A sterile flexible tube designed for the percutaneous, transluminal disruption and removal of clotted blood (i.e., a thrombus or thromboembolus) or other formed elements causing vascular obstruction in native and stented blood vessels, native and synthetic ...
An atraumatic, invasive, hand-operated, single-lumen, rigid/semi-rigid tube designed as a conduit for aspiration of body cavities, wounds, or surgical sites to facilitate observation and/or to clear an airway obstruction. It is not dedicated to dental, intr...
An atraumatic, invasive, hand-operated, single-lumen, rigid/semi-rigid tube designed as a conduit for aspiration of body cavities, wounds, or surgical sites to facilitate observation and/or to clear an airway obstruction. It is not dedicated to dental, intr...
An atraumatic, invasive, hand-operated, single-lumen tube designed as a conduit for aspiration of body cavities, wounds, or surgical sites to facilitate observation and/or to clear an airway obstruction. It is not dedicated to dental, intrauterine, or lipos...
An atraumatic, invasive, hand-operated, single-lumen tube designed as a conduit for aspiration of body cavities, wounds, or surgical sites to facilitate observation and/or to clear an airway obstruction. It is not dedicated to dental, intrauterine, or lipos...
An atraumatic, invasive, single-lumen tube designed as a conduit for aspiration of body cavities, wounds, or surgical sites to facilitate observation and/or clear an airway obstruction, whilst providing illumination of the site. It is not dedicated to denta...
A device intended to create a direct connection between a breathing circuit breathing tube and an endotracheal (ET) tube, anaesthesia face mask, or other non-sampling breathing circuit component. It is constructed with specific connecting dimensions and may...
A device intended to create a direct connection between a breathing circuit breathing tube and an endotracheal (ET) tube, anaesthesia face mask, or other non-sampling breathing circuit component. It is constructed with specific connecting dimensions and may...
A sterile, thin, flexible, hollow cylinder designed to access the small intestines (duodenum or jejunum) through the nose and nasopharynx for examination (e.g., of intestinal contents), treatment (e.g., decompression, short-term feeding), or other purposes....
A non-sterile device intended to connect a breathing circuit breathing tube to an endotracheal (ET) tube, anaesthesia face mask, or other non-sampling breathing circuit component. It is constructed with standardized connecting dimensions and may be designed...
A non-sterile device intended to connect a breathing circuit breathing tube to an endotracheal (ET) tube, anaesthesia face mask, or other non-sampling breathing circuit component. It is constructed with specific connecting dimensions and may be designed to ...
A non-sterile device intended to connect a breathing circuit breathing tube to an endotracheal (ET) tube, anaesthesia face mask, or other non-sampling breathing circuit component. It is constructed with standardized connecting dimensions and may be designed...
A device intended to connect a breathing circuit breathing tube to an endotracheal (ET) tube, anaesthesia face mask, or other non-sampling breathing circuit component. It is constructed with specific connecting dimensions and may be designed to connect brea...
A sterile, thin, flexible, hollow, single- or double-lumen cylinder intended to access the stomach of a patient through the nose and nasopharynx primarily to reduce the pressure within the gastrointestinal tract, typically aided by connection to an intermit...
A sterile device intended to connect a breathing circuit breathing tube to an endotracheal (ET) tube, anaesthesia face mask, or other non-sampling breathing circuit component. It is constructed with specific connecting dimensions and may be designed to conn...
A sterile device intended to connect a breathing circuit breathing tube to an endotracheal (ET) tube, anaesthesia face mask, or other non-sampling breathing circuit component. It is constructed with standardized connecting dimensions and may be designed to ...
A device designed to connect a respiratory circuit (e.g., an anaesthesia breathing circuit or ventilator breathing circuit) or a resuscitator to an endotracheal (ET) tube, to enable increased mobility at the patient end of the circuit or connections. It mos...
A portable assembly of devices designed to apply suction to help heal traumatic and chronic skin wounds (e.g., grafts, incisions, burns, ulcers) with low to moderate levels of exudate. It typically consists of an electrically-powered vacuum pump, a highly-a...
A portable assembly of devices designed to apply suction to help heal traumatic and chronic skin wounds (e.g., grafts, incisions, burns, ulcers) with low to moderate levels of exudate. It typically consists of a non-sterile battery-powered vacuum pump, a hi...
A device designed to connect a respiratory circuit (e.g., an anaesthesia breathing circuit or ventilator breathing circuit) or a resuscitator to an endotracheal (ET) tube, to enable increased mobility at the patient end of the circuit or connections. It mos...
A device used to connect a respiratory circuit (e.g., an anaesthesia breathing circuit or ventilator breathing circuit) or a resuscitator to an endotracheal (ET) tube, to enable increased mobility at the patient end of the circuit or connections. It most co...
A device designed to connect a respiratory circuit (e.g., an anaesthesia breathing circuit or ventilator breathing circuit) or a resuscitator to an endotracheal (ET) tube, to enable increased mobility at the patient end of the circuit or connections. It mos...
A sterile, thin, flexible, hollow cylinder intended to be used to mechanically decompress the colon, typically by connection to an intermittent suction system, to treat conditions including non-toxic megacolon, pseudo-obstruction (Ogilvie syndrome) and/or c...
A device used to connect a respiratory circuit (e.g., an anaesthesia breathing circuit or ventilator breathing circuit) or a resuscitator to an endotracheal (ET) tube, to enable increased mobility at the patient end of the circuit or connections. It most co...
A sterile length of flexible tube intended to be used as a connection line between a vacuum source and a medical device, medical equipment, or a medical system that is dependent upon suction to operate or function. It is typically made of malleable syntheti...
A sterile hand-operated device designed to mix polymethylmethacrylate (PMMA) powder with methylmethacrylate monomer in order to produce polymerizing bone cement. It typically consists of a vessel with attached/attachable mixing blades where the cement is mi...
A rigid, hand-operated, single-lumen tube intended to be inserted through a laparoscopic port to provide a conduit for irrigation of body cavities/wounds during a laparoscopic procedure, to facilitate observation. It is not designed to administer parenteral...
A sterile device intended to be inserted through the working channel of a rigid nephroscope during laser lithotripsy to function as a channel for insertion of the laser fibre of an endotherapy laser beam guide, and for removal of debris (e.g., fluid, calcul...