A device intended to cover the tip of a syringe (without a needle) in order to prevent the leakage of syringe contents and to maintain content sterility until the syringe is used. This device is typically constructed of plastic. This is a single-use device.
A sterile device consisting of a calibrated barrel (cylinder) with plunger intended to be used for injection/withdrawal of fluids/gas (e.g., medication) to/from a medical device or the body (i.e., capable of both); a non-retractable needle is included, eith...
A sterile device consisting of a graduated barrel (cylinder) with plunger intended to be used to deliver (inject) or withdraw an accurate metered dose of a fluid to/from the body. The application of the content of this device may be in conjunction with an i...
A collection of sterile devices designed to inject dental anaesthetics into gingival tissue or the oral mucosa, while preventing or reducing the risk of accidental needle-stick injury, during restorative or surgical dental procedures. It typically includes ...
A sterile device intended to be used in conjunction with an epidural needle to aid a user in locating the epidural needle tip within the epidural space. It is typically a small chamber made of synthetic polymers with Luer inlet and exit ports on opposing si...
A hand-operated device designed to hold a biopsy syringe to facilitate precision aspiration of a tissue specimen through a biopsy needle. The holder is typically made of metal and plastic materials and typically designed as a lightweight, hand-held frame in...
A hand-operated device designed to hold a biopsy syringe to facilitate precision aspiration of a tissue specimen through a biopsy needle. The holder is typically made of metal and plastic materials and typically designed as a lightweight, hand-held frame in...
A sterile device consisting of a calibrated barrel (cylinder) with plunger intended to be used for injection/withdrawal of fluids/gas (e.g., medication) to/from a medical device or the body (i.e., capable of both); a needle is not included. It is intended f...
A non-sterile device consisting of a calibrated barrel (cylinder) with plunger intended to be used for injection/withdrawal of fluids/gas (e.g., medication) to/from a medical device or the body (i.e., capable of both); it is intended for various medical app...
A sterile glass or plastic syringe, without a pre-attached needle, containing the anticoagulant lithium heparin intended to be used for the collection, and preservation and/or transport, of blood for blood gas determination and/or other investigation. This ...
A sterile glass or plastic syringe, without a pre-attached needle, containing the anticoagulant sodium heparin intended to be used for the collection, and preservation and/or transport, of blood for blood gas determination and/or other investigation. This i...
A non-dedicated, sharp bevel-edged, hollow tubular device intended to be inserted beneath the skin of a patient while connected to a noninvasive device (e.g., syringe, secondary medication set) to administer and/or withdraw (aspirate) fluids/drugs; it may a...
A collection of sterile devices intended to be used with an epidural needle (not included) and an electronic epidural space locator control unit, to aid a user in locating the epidural needle tip within the epidural space for subsequent anaesthesia administ...
An assembly of devices intended to measure hepatic portal pressure gradient by direct measurements of pressure within the hepatic vein and portal vein using a needle inserted via the stomach or duodenum under ultrasound guidance during endoscopy. It consist...
An assembly of devices designed to measure and display, periodically or continuously, the interstitial pressure in a closed fascial compartment of muscle. It typically consists of a battery-powered, hand-held, pressure-measuring instrument with a display an...
A small, cylindrical container intended to temporarily store venous blood and subsequently placed in a centrifuge to produce platelet rich fibrin (PRF) or platelet rich plasma (PRP) for application to the patient from whom the blood was taken (typically for...
An assembly of sterile devices designed to measure and display, periodically or continuously, the interstitial pressure in a closed fascial compartment of muscle. It typically consists of a battery-powered, hand-held, pressure-measuring instrument with a di...
A non-dedicated, sharp bevel-edged, hollow tubular device intended to be inserted beneath the skin of a patient while connected to a noninvasive device (e.g., syringe, secondary medication set) to administer and/or withdraw (aspirate) fluids/drugs; it may a...
A non-sterile, sharp bevel-edged, hollow tubular metal device intended to be used in conjunction with syringes, secondary medication sets, or phlebotomy equipment (e.g., blood collection adapters or holders) to prepare and administer fluids/medications/drug...
A sharp bevel-edged, hollow tubular metal device intended to be used in conjunction with syringes, secondary medication sets, or phlebotomy equipment (e.g., blood collection adapters or holders) to prepare and administer fluids/medications/drugs to a patien...