ADSOL Red Cell Preservation Solution System in Plastic Container (PL 146 Plastic)
ANTICOAGULANT CITRATE PHOSPHATE DEXTROSE (CPD) SOLUTION AND ADSOL PRESERVATION SOLUTION
50 matching records for T-CONNECTOR, PLASTIC.
ANTICOAGULANT CITRATE PHOSPHATE DEXTROSE (CPD) SOLUTION AND ADSOL PRESERVATION SOLUTION
ANTICOAGULANT CITRATE PHOSPHATE DEXTROSE (CPD) SOLUTION AND ADSOL PRESERVATION SOLUTION
ANTICOAGULANT CITRATE PHOSPHATE DEXTROSE (CPD) SOLUTION AND ADSOL PRESERVATION SOLUTION
ANTICOAGULANT CITRATE PHOSPHATE DEXTROSE (CPD) SOLUTION AND ADSOL PRESERVATION SOLUTION
ANTICOAGULANT CITRATE PHOSPHATE DEXTROSE (CPD) SOLUTION AND ADSOL PRESERVATION SOLUTION
ANTICOAGULANT CITRATE PHOSPHATE DEXTROSE (CPD) SOLUTION AND ADSOL PRESERVATION SOLUTION
ANTICOAGULANT CITRATE PHOSPHATE DEXTROSE (CPD) SOLUTION AND ADSOL PRESERVATION SOLUTION
BROAD SPECTRUM SPF30
BROAD SPECTRUM SPF30
BROAD SPECTRUM SPF30
TITANIUM DIOXIDE, ZINC OXIDE
TITANIUM DIOXIDE, ZINC OXIDE
TITANIUM DIOXIDE, ZINC OXIDE
TITANIUM DIOXIDE, ZINC OXIDE
ZINC OXIDE
TITANIUM DIOXIDE, ZINC OXIDE
ZINC OXIDE
TITANIUM DIOXIDE, ZINC OXIDE
TITANIUM DIOXIDE, ZINC OXIDE
ZINC OXIDE
A non-sterile device consisting of a calibrated barrel (cylinder) with plunger intended to be used to administer (infuse) anaesthetic drugs. At the distal end of the barrel is a male Luer connector (typically a Luer-lock type) for the attachment of the fema...
A sterile, single-lumen, tubular device designed to be used during cardiac surgery to flush an autologous graft, typically a section of explanted saphenous vein, to test its integrity and the closure of lateral vessels, as well as to remove debris and clots...
A small, sterile valve intended to be connected to a urethral and/or suprapubic catheter to allow intermittent bladder drainage/filling (as an alternative to continuous drainage). As the bladder is intended to store urine between drainage it may be intended...
A sterile device consisting of a calibrated barrel (cylinder) with plunger intended to be used to administer (infuse) anaesthetic drugs. At the distal end of the barrel is a male Luer connector (typically a Luer-lock type) for the attachment of the female c...
A device consisting of a calibrated barrel (cylinder) with plunger intended to be used to administer (infuse) anaesthetic drugs. At the distal end of the barrel is a male Luer connector (typically a Luer-lock type) for the attachment of the female connector...
A sterile tubing set that is a component of a magnetic cell separation system intended to be used for the magnetic separation of target cell types or subpopulations from heterogeneous human cell preparations. It typically consists of flexible plastic tubes,...
A collection of sterile devices intended to be used with a mechanical infusion pump (non-electric) to enable the intermittent or continuous infusion of medication, typically for antibiotic therapy, chemotherapy, or pain management [including patient-control...
A collection of devices intended to be used with a mechanical infusion pump (non-electric) to enable the intermittent or continuous infusion of medication (not included), typically for antibiotic therapy, chemotherapy, or pain management [including patient-...
A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer of priming fluids during the priming of the extracorporeal circuit of a cardiopulmonary bypass system. It is a noninvasive product in the form of a tube or tubing used to chann...
A collection of sterile devices that typically consists of a reservoir (e.g., a syringe or plastic pouch), plastic tubing, a check valve, and Luer connectors, designed for the controlled intravenous (IV) administration of opioid pain medication using an ele...
A sterile device consisting of a calibrated barrel (cylinder) with plunger intended to be used for injection/withdrawal of fluids/gas (e.g., medication) to/from a medical device or the body (i.e., capable of both); a needle is not included. It is intended f...
A collection of sterile devices (e.g., plastic tubing, check valve, roller clamp, Y-site connector, Luer, needle/catheter) intended to be used in combination with an electrically-powered infusion pump for the intravenous (IV), subcutaneous, intramuscular, o...
A collection of noninvasive devices designed to conduct fluids between a contrast medium injection system and a patient catheter for the delivery of a contrast medium and/or saline solution to a patient undergoing a diagnostic imaging procedure. It consists...
A component of a rigid or flexible endoscope assembly designed as a tube through which an endoscope (e.g., hysteroscope) and endoscopic elements are introduced and assembled to create a complete operative endoscopic unit; it is also designed to function as ...
A hollow cylinder inserted orally or nasally into the trachea to provide an unobstructed airway to convey gases and vapours to and from the lungs during anaesthesia, resuscitation, and other situations where the patient is not properly ventilated. The devic...
A tube-like, non-bioabsorbable device designed to establish a channel for the removal of fluid or purulent material from a closed-wound or an infected area, typically used with a closed drainage system that applies a low negative pressure through the drain ...
A curved tube with a distal inflatable cuff/mask intended to be used in inhalational anaesthesia and resuscitation to facilitate and secure airway patency for the delivery and exchange of gases in spontaneously breathing and ventilated patients. It is inser...
A flexible fibreoptic cable that is designed to transport cold light from a light source to an instrument or other equipment, e.g., an endoscope or a headlight. The fibreoptic bundle is protected within a sheath and can be made of either glass or plastic fi...
A rubber or plastic tube that extends into the pharynx from either naris to maintain airway patency. The proximal end of the device may have an integral 22 mm connector for oxygen delivery. This is a single-use device.
A device intended to create a direct connection between a breathing circuit breathing tube and an endotracheal (ET) tube, anaesthesia face mask, or other non-sampling breathing circuit component. It is constructed with specific connecting dimensions and may...
A sterile, tube-like device designed to establish a channel for the removal of fluid or purulent material from a closed-wound or an infected area, typically used with a closed drainage system that applies a low negative pressure through the drain lumen. It ...
A sterile, hollow cylinder that can be introduced into the gastrointestinal (GI) tract both nasally and orally for feeding and/or aspiration. It is made of plastic or rubber and is available in a variety of designs and lengths. Some types are a simple rubbe...
A hollow cylinder that is designed for oral insertion via the trachea and into a lung to maintain airway patency and/or to deliver anaesthetic inhalation agents or other medical gases, and secure ventilation. It is typically made of plastic, rubber, or sili...
An armoured hollow cylinder inserted orally or nasally into the trachea to provide an unobstructed airway to convey gases and vapours to and from the lungs during anaesthesia, resuscitation, and other situations where the patient is not properly ventilated....
A small, stand-alone, Luer-activated needleless plastic valve intended to mate two related intravenous (IV) line devices [e.g., hypodermic syringe and catheter port or tubing from an IV administration set] and hold them in a secured, sealed, locked position...
A component of a rigid or flexible endoscope assembly designed as a tube through which an endoscope (e.g., hysteroscope) and endoscopic elements are introduced and assembled to create a complete operative endoscopic unit; it is also designed to function as ...
A sterile device designed to allow access to either the Y-site of an intravenous (IV) line or an injection adaptor on the infusion catheter. Typically, a needle located inside a plastic housing can be inserted into a standard septum and a Luer fitting locat...
A small clip designed to enable an electrical connection between an electrocardiographic electrode and an electrocardiographic lead wire. It is typically made of plastic materials, with a metallic part to provide electrical connection, and can be manually a...
A device designed for partial insertion into a patient's mouth (in between the lips) to facilitate access to the respiratory system. It is typically a small rigid or semi-rigid plastic hollow device with a shape and structure that enables an appropriate gas...
A sterile, single lumen, tubular device designed to deliver cardioplegic solution to the aortic root to stop the beating of the heart and maintain it dormant; it may also be used to vent the aorta and the left heart during a cardiopulmonary bypass procedure...