A copy of a final transfemoral amputation tissue-reinforcement implant intended to be used during orthopaedic surgery to accurately size a transfemoral amputation tissue-reinforcement implant (medullary canal rod and bulb) prior to implantation, following a...
A covered receptacle (single- or multiple-compartment) containing a tissue fixation or preservation solution [e.g., formalin, saline] intended to be used for the collection, and preservation and/or transport, of any type of tissue specimen (e.g., biopsy tis...
A collection of sterile components of a mechanical skin contouring system intended to temporarily minimize the manifestation of cellulite by transection of the cellulite-tethering fibrous tissue by motorized mechanical means. It consists of template plates,...
A photoelectric device that is applied externally to a site on the body surface of a paediatric or adult patient for transcutaneous measurement the percent oxygen saturation of haemoglobin in a volume of tissue (StO2) to assess the amount of oxygen delivere...
A hand-held component of a tissue morcellation system intended to be used to mechanically cut (slice), core (cut a hole into), peel (remove surface), and extract selected tissue from the body during surgery. It consists of a high-speed rotating blade in a h...
A hand-operated surgical instrument designed for the automatic extraction of a small tissue sample from an anatomic structure of the body (i.e., a biopsy), while causing minimal surrounding tissue damage, for pathological examination/testing. It has a sprin...
A mains electricity (AC-powered) photoelectric device that noninvasively calculates the percent oxygen saturation of haemoglobin in a volume of tissue (StO2) to assess the amount of oxygen delivered to that tissue, typically during circulatory or perfusion ...
A photoelectric device that is applied externally to a site on the body surface of a paediatric or adult patient for transcutaneous measurement the percent oxygen saturation of haemoglobin in a volume of tissue (StO2) to assess the amount of oxygen delivere...
A sterile device intended to be fitted into a suction system bottle/canister to separate tissue from the aspirate during a surgical procedure; the tissue may be subsequently used for various diagnostic/therapeutic purposes (e.g., autologous fat tissue trans...
A hand-operated surgical instrument designed for the automatic extraction of a core tissue sample from an anatomic structure of the body (i.e., a biopsy), while causing minimal surrounding tissue damage, for pathological examination/testing. It has a spring...
A collection of equipment (e.g., moulds and instruments for tissue sampling and transfer) used to create a fixed array of tissue samples, usually for the parallel histopathological or immunohistochemical analysis of different tissues. The tissue samples are...
A hand-held component of an ultrasonic surgical system which includes a holder with controls and a surgical endpiece (tip) intended to be connected to a system transducer (not included) whereby the tip oscillates (vibrates) at high frequency in order to fra...
A hand-held component of an ultrasonic surgical system which includes a holder with controls and a surgical endpiece (tip) intended to be connected to a system transducer (not included) whereby the tip oscillates (vibrates) at high frequency in order to fra...
A hand-held component of an ultrasonic surgical system which includes a holder with controls and a surgical endpiece (tip) intended to be connected to a system transducer (not included) whereby the tip oscillates (vibrates) at high frequency in order to fra...
A sterile, hand-held component of an ultrasonic surgical system which includes a holder with controls and a surgical endpiece (tip) intended to be connected to a system transducer (not included) whereby the tip oscillates (vibrates) at high frequency in ord...
A patient-contact dilating/measuring component of an endoscopic soft-tissue release system intended to be used for minimally-invasive transection of soft connective tissue (e.g., fascia, tendon) under direct vision. It consists of a probe-like device that i...
A sterile, hand-held component of an ultrasonic surgical system which includes a holder with controls and a surgical endpiece (tip) intended to be connected to a system transducer (not included) whereby the tip oscillates (vibrates) at high frequency in ord...
An assembly of devices intended to use high intensity focused ultrasound (HIFU) energy to create heat at controlled temperatures for noninvasive (transcutaneous) thermal ablation of neural tissue to treat chronic pain, typically through ablation of medial b...
A device intended to be used with a hand-held ultrasound (US) imaging system transducer to provide a means to attach/hold an electromagnetic (EM) sensor or needle guide to the distal end of the US transducer in a repeatable position (can detach/reattach to ...
A metal or plastic bracket intended to be applied to a hand-held ultrasound (US) transducer for the repeatable positioning (detach from/reattach to same place) of an electromagnetic (EM) sensor and/or needle guide on the transducer. It may be used in conjun...
A metal or plastic bracket manually applied to a hand-held ultrasound (US) transducer intended to provide a means to attach/hold an electromagnetic (EM) sensor or needle guide to the distal end of the US transducer in a repeatable position (can detach/reatt...
A metal or plastic bracket intended to be applied to a hand-held ultrasound (US) transducer for the repeatable positioning (detach from/reattach to same place) of an electromagnetic (EM) sensor and/or needle guide on the transducer. It may be used in conjun...
A metal or plastic bracket manually applied to a hand-held ultrasound (US) transducer intended to provide a means to attach/hold an electromagnetic (EM) sensor or needle guide to the distal end of the US transducer in a repeatable position (can detach/reatt...
An impervious, flexible, sterile container intended to be used during minimally-invasive, typically keyhole, surgical techniques (e.g., laparoscopic) to extract dissected patient body tissue. The device is inserted into the body through a large bore cannula...
Skin tissue intended for transplantation that is harvested from an animal donor (e.g., porcine source) and implanted in a human recipient. The tissue is used to temporarily replace skin (for a few days) typically lost due to extensive wounds and burns, when...
A solution intended to be used for the flushing, transport, storage and preservation of donor cells, tissues and/or organs (e.g., stem cells, skin, amniotic membrane, cardiovascular tissue, bone, tendon, kidney, liver, heart, pancreas) intended for transpla...
A collection of sterile devices designed to hold and deliver prepared donor endothelial tissue for transplantation into a recipient eye following the removal of Descemet's membrane and dysfunctional endothelium from the patient's cornea during ophthalmic su...
A covered receptacle containing no additives intended to be used for the collection, and preservation and/or transport, of any type of tissue specimen (e.g., biopsy tissue) collected from any body part for in vitro diagnostic investigation. It does not cont...
A patient-contact cutting component of an endoscopic soft-tissue release system intended to be used for minimally- invasive transection of soft connective tissue (e.g., fascia, tendon) under direct vision. It consists of a blade within a fenestrated tube th...
A covered receptacle containing normal or formal saline solution intended to be used for the collection, and preservation and/or transport, of any type of tissue specimen (e.g., biopsy tissue) collected from any body part for in vitro diagnostic investigati...