A slender electrical conductor with a connection cable intended to be inserted within the lumen of an irreversible electroporation system percutaneous probe to deliver short electrical pulses, in a monopolar configuration, from a system generator to the pro...
A slender electrical conductor with a connection cable intended to be inserted within the lumen of an irreversible electroporation system probe (i.e., a percutaneous and/or endoscopic probe) to deliver short electrical pulses, in a monopolar configuration, ...
A polymer sheath intended to be used to cover an intraoperative fluorescence imaging system probe (not included), to create a physical barrier between the patient and the probe, while optimising image acquisition by maintaining an ideal focal distance betwe...
A sterile electronic probe intended to be connected to a system analyser (not included) for tissue surface analysis and characterization using radio-frequency spectroscopy, to identify cancerous tissue at the cut-lines (margins) during a lumpectomy procedur...
A sterile distal component of a probe-like ophthalmic soft-tissue surgical forceps assembly designed to grasp and manipulate intraocular tissues during ophthalmic surgery (e.g., anterior segment surgery, vitreo-retinal procedures, iridectomy, capsulorhexis)...
A distal component of a probe-like ophthalmic soft-tissue surgical forceps assembly designed to grasp and manipulate intraocular tissues during ophthalmic surgery (e.g., anterior segment surgery, vitreo-retinal procedures, iridectomy, capsulorhexis). It is ...
A distal component of a probe-like intraocular scissors assembly intended to be used to cut intraocular tissue (e.g., during anterior chamber surgery, vitrectomy). It is a probe-/cannula-like shaft with two shearing blades at the end, and is intended to be ...
An active, hand-held surgical instrument designed to connect to a microwave ablation system generator to deliver microwaves to a targeted operative site for localized soft-tissue ablation, typically to treat tumours, hydatid cysts and/or menorrhagia. The pr...
A sterile, distal component of a probe-like intraocular scissors assembly intended to be used to cut intraocular tissue (e.g., during anterior chamber surgery, vitrectomy). It is a probe-/cannula-like shaft with two shearing blades at the end, and is intend...
A device (a probe) intended to be used exclusively to monitor tissue or body temperature during hyperthermia treatments. Depending on the kind of hyperthermia system it is used with, e.g., ultrasound, radio-frequency (RF) or microwave, this probe is shielde...
A hand-held device intended to be used to monitor tissue temperature during a cryosurgical procedure, typically to measure the temperature in tissue adjacent to the ablated zone to assess extent of ablation and to limit ablation to protect local tissues. It...
A mains electricity (AC-powered) device designed to provide energy for a system designed to perform arthroscopic shaving (i.e., abrasion, resection, debridement of bone and soft tissue with a blade) and electrosurgical diathermy (i.e., the ablation and coag...
A hand-held component of an intraoperative parathyroid detection system designed to aid surgeons in recognizing parathyroid tissue during open surgical thyroidectomies and parathyroidectomies using near-infrared (NIR) light and auto-fluorescence. The probe ...
A sterile hand-held component of an intraoperative parathyroid detection system designed to aid surgeons in recognizing parathyroid tissue during open surgical thyroidectomies and parathyroidectomies using near-infrared (NIR) light and auto-fluorescence. Th...
An assembly of noninvasive devices intended for use during soft-tissue lesion treatment by ultrasound-guided laser thermal therapy, to provide software-based simulation of tissue thermal damage for assisting the manual positioning of percutaneous needles th...
A sterile rigid tube designed to provide body tissue access through its lumen for a radio-frequency (RF) probe during RF ablation procedures (typically of peripheral nerves to treat chronic pain) and for the injection/aspiration of fluids (e.g., local anaes...
A rigid tube designed to provide percutaneous (through the skin) tissue access through its lumen for an electrosurgical probe during radio-frequency (RF) ablation procedures (typically of peripheral nerves to treat chronic pain) and for the injection/aspira...
A sterile, hand-held manual instrument designed to grasp and manipulate intraocular tissues during ophthalmic surgery (e.g., anterior segment surgery, vitreo-retinal procedures, iridectomy, capsulorhexis). It has a probe-like design with a proximal handle (...
A hand-held manual instrument designed to grasp and manipulate intraocular tissues during ophthalmic surgery (e.g., anterior segment surgery, vitreo-retinal procedures, iridectomy, capsulorhexis). It has a probe-like design with a proximal handle (typically...
A sterile, hand-held manual instrument designed to grasp and manipulate intraocular tissues during ophthalmic surgery (e.g., anterior segment surgery, vitreo-retinal procedures, iridectomy, capsulorhexis). It has a probe-like design with a proximal handle (...
A hand-held manual instrument designed to grasp and manipulate intraocular tissues during ophthalmic surgery (e.g., anterior segment surgery, vitreo-retinal procedures, iridectomy, capsulorhexis). It has a probe-like design with a proximal handle (typically...
A hand-held, manual, ophthalmic surgical instrument intended to be used to cut intraocular tissue (e.g., during anterior chamber surgery, vitrectomy). As a complete instrument it comprises two shearing blades at the end of a probe-/cannula-like shaft with a...
A hand-held surgical instrument designed to connect to a microwave ablation system generator to deliver microwaves to a targeted operative site for localized soft-tissue ablation, typically to treat tumours and/or hydatid cysts. The probe includes a handle ...
A rigid tube designed to provide percutaneous (through the skin) tissue access through its lumen for an electrosurgical probe during radio-frequency (RF) ablation procedures (typically of peripheral nerves to treat chronic pain) and for the injection/aspira...
A battery-powered, speech-assistive device designed to be used by a person who has had their larynx removed (laryngectomy) to assist them in the reproduction of sounds similar to those produced by the vocal cords in normal speech. It is an externally-applie...
A sterile, hand-held, manual, ophthalmic surgical instrument intended to be used to cut intraocular tissue (e.g., during anterior chamber surgery, vitrectomy). As a complete instrument it comprises two shearing blades at the end of a probe-/cannula-like sha...
A non-active, hand-held surgical instrument designed to connect to a microwave ablation system generator to deliver microwaves to a targeted operative site for localized soft-tissue ablation, typically to treat tumours, hydatid cysts and/or menorrhagia. The...
An assembly of mains electricity-powered (AC-powered) devices designed to produce microscopic cross-sectional images of tissues within non-vascular luminal structures [e.g., gastrointestinal tract (GI), urinary tract, respiratory tract] during an endoscopic...
A flexible distal component of a cryosurgical system intended to be inserted through the working channel of an endoscope for cryoadhesion and devitalization of tissues during interventional procedures (e.g., bronchoscopy/interventional pulmonology). It is c...
A mains electricity (AC-powered) device assembly intended to be used by a healthcare professional to non-invasively evaluate a skin lesion clinically suspicious for carcinoma (e.g., melanoma, squamous cell) and precursors, before making a decision to biopsy...