31 GUDID devices
A mains electricity (AC-powered) portable electronic device assembly, typically with rechargeable battery, designed to detect, record, and display an electromagnetic (EM) signal emitted from a transmitter in an enteral feeding tube stylet to facilitate the ...
1,824 GUDID devices
A radio-frequency (RF) coil acts as a transmitter, receiver, or both a transmitter and receiver of RF pulses necessary for diagnostic magnetic resonance imaging (MRI) procedures. It is used to enhance image resolution by improving signal to noise characteri...
540 GUDID devices
A battery-powered assembly of devices [cochlear implant (CI)] intended for the partial restoration of auditory sensation to a severely/profoundly deaf person. It consists of an inner electrode array implanted in one cochlea and connected to a receiver-stimu...
126 GUDID devices
A battery-powered assembly of devices [cochlear implant (CI)] intended for the partial restoration of auditory sensation to a profoundly deaf person. It consists of an inner electrode array implanted in one cochlea and connected to a receiver-stimulator imp...
123 GUDID devices
A body-worn, battery-powered component of an electrocardiography telemetric monitoring system designed to continuously measure and wirelessly transmit real-time electrocardiographic (ECG) signals [and sometimes additional parameters such as heart rate, skin...
112 GUDID devices
A non-sterile, thin, flexible wire with an electromagnetic (EM) transmitter at the distal end that is a component of an enteral tube tracking system and intended to be used as a stylet for an enteral feeding tube with which it is supplied. It is designed to...
39 GUDID devices
A body-worn, battery-powered component of a pulse oximetry telemetric monitoring system designed to continuously measure and wirelessly transmit haemoglobin oxygen saturation (SpO2) signals to the system's receiver. The transmitter typically includes an ant...
34 GUDID devices
A battery-powered assembly of devices [cochlear implant (CI)] intended for the partial restoration of auditory sensation to a severely/profoundly deaf person. It consists of an inner electrode array implanted in one cochlea and connected to a receiver-stimu...
16 GUDID devices
A sterile device intended to be implanted subcutaneously for continuous monitoring of glucose levels in interstitial fluid, typically for detecting trends and tracking patterns in patients with diabetes mellitus. It is a small, rod-shaped sensor consisting ...
15 GUDID devices
A non-sterile component of a medication adherence telemetric monitoring system intended to be ingested simultaneously with medication to transmit an electrical signal across tissues to a patient worn transceiver indicating that the medication has been taken...
14 GUDID devices
A hand-held, electrically-powered device designed to be operated by a clinician or patient to non-invasively change the settings (e.g., turn on/off) of an implantable cardiac monitor (ICM), and/or extract data from the implant, and/or provide an alarm funct...
12 GUDID devices
A body-worn, battery-powered component of a cardiotocography telemetric monitoring system designed to continuously measure and wirelessly transmit foetal heart rate and uterine contraction signals to the system's receiver. The transmitter typically includes...
11 GUDID devices
A noninvasive electronic component of an intravenous (IV) injection automated detection/documentation system, intended to electronically interface with a system sensor to: 1) provide power to, and extract IV bolus injection volume data from, the sensor; and...
10 GUDID devices
A body-worn, battery-powered component of an electroencephalography telemetric monitoring system designed to continuously measure and wirelessly transmit electroencephalographic (EEG) signals to the system's receiver. The transmitter typically includes an a...
7 GUDID devices
A non-sterile component of a medication adherence telemetric monitoring system intended to be ingested simultaneously with medication to transmit an electrical signal across tissues to a patient worn transceiver indicating that the medication has been taken...
7 GUDID devices
An assembly of electronic devices intended to help assess the medication adherence of a patient who is self-managing oral medication by monitoring medication ingestion. It consists of a transmitter(s) intended to be swallowed by the patient with their medic...
7 GUDID devices
A body-worn, battery-powered component of a temperature telemetric monitoring system designed to continuously measure and wirelessly transmit core and/or skin temperature signals to the system's receiver. It typically consists of a portable radio transmitte...
2 GUDID devices
A sterile, invasive, flexible wire with an electromagnetic (EM) coil transmitter at the distal end designed to be inserted into an intracranial catheter to help guide the surgical insertion of the catheter through the skull for placement in the brain. It is...
2 GUDID devices
A radio-frequency (RF) coil acts as a transmitter, receiver, or both a transmitter and receiver of RF pulses necessary for diagnostic magnetic resonance imaging (MRI) procedures. It is used to enhance image resolution by improving signal to noise characteri...
1 GUDID devices
A body-worn, battery-powered component of an electromyography telemetric monitoring system designed to continuously measure and wirelessly transmit electromyographic (EMG) signals to the system's receiver. The transmitter typically includes an antenna and a...
1 GUDID devices
A hermetically-sealed device intended to be implanted beneath the skin of the chest in a surgically-created pocket to: 1) sense signals from a separate co-implanted pacemaker; and 2) generate and transmit synchronized ultrasound (US) pulses to a left-ventri...
1 GUDID devices
An electrically-powered device designed to be connected to a thorax-placed electrode array (not included) to collect, process, and wirelessly transmit respiration rate signal data for subsequent display on a separate monitor. It is a small unit with an elec...
1,483 GUDID devices
An assembly of electronic devices, integrated within a facility infrastructure and/or wireless network, designed to provide an audio/visual signal to summon help when activated in response to a patient’s need for (urgent) assistance. It typically consists o...
1,194 GUDID devices
An assembly of electrically-powered devices designed for the continuous assessment of several vital physiologic parameters (e.g., ECG, blood pressure, heart rate, temperature, cardiac output, apnoea, and respiratory/anaesthetic gas concentrations) of one pa...
541 GUDID devices
The non-sterile external portion of a cochlear implant system [cochlear implant (CI)] that typically consists of a battery-powered microphone/transmitter (transducer) designed to convert sound waves from the environment into electrical signals which are tra...
389 GUDID devices
An external component of a cochlear implant (CI) or auditory brainstem implant system that typically consists of a battery-powered microphone/transmitter (transducer) designed to convert sound waves from the environment into electrical signals which are tra...
377 GUDID devices
A collection of battery-powered devices designed to be worn by a person (typically a child) wearing a compatible hearing aid to enhance the sound quality they receive by reducing background noise and/or room reverberation potentially found in a teaching env...
323 GUDID devices
A battery-powered electronic device intended to provide an alert signal for help when manually activated by a user in response to a need of assistance (e.g., general care, low insulin levels). It typically consists of a bedside, wall-affixed, push-button or...
271 GUDID devices
An electrically-powered device/device assembly designed for the continuous assessment of several vital physiologic parameters (e.g., ECG, blood pressure, heart rate, temperature, cardiac output, apnoea, and respiratory/anaesthetic gas concentrations) of one...
258 GUDID devices
An assembly of devices designed to continuously measure and wirelessly transmit electrocardiographic (ECG) signals from a patient to a receiving location (e.g., central station, bedside monitor) for viewing. It typically consists of a portable transmitter w...