A non-sterile, sheath-covered device intended to be used to mechanically clear a clog in an in situ nasogastric, nasoenteral, gastrostomy and/or jejunostomy tube, used for feeding and/or decompression, to maintain luminal patency. It consists of a sheath an...
A device intended to be worn on or over the penis by an incontinent patient to channel urine from the penis, via a tube, into a collection bag. It consists of a penis-worn sheath (e.g., condom-catheter) or adhesive port (e.g., glans penis attachment), and m...
A non-sterile device intended to be worn on or over the penis by an incontinent patient to channel urine from the penis, via a tube, into a collection bag. It consists of a penis-worn sheath (e.g., condom-catheter) or adhesive port (e.g., glans penis attach...
A sterile device designed to be used with a transseptal introducer sheath to penetrate the interatrial septum to gain left-heart access during a transseptal catheterization procedure. It is typically a long, thin tube made of plastic that is curved and roun...
An atraumatic, invasive, hand-operated, single-lumen, rigid/semi-rigid tube designed as a conduit for aspiration of body cavities, wounds, or surgical sites to facilitate observation and/or to clear an airway obstruction. It is not dedicated to dental, intr...
An atraumatic, invasive, hand-operated, single-lumen, rigid/semi-rigid tube designed as a conduit for aspiration of body cavities, wounds, or surgical sites to facilitate observation and/or to clear an airway obstruction. It is not dedicated to dental, intr...
An atraumatic, invasive, hand-operated, single-lumen tube designed as a conduit for aspiration of body cavities, wounds, or surgical sites to facilitate observation and/or to clear an airway obstruction. It is not dedicated to dental, intrauterine, or lipos...
An atraumatic, invasive, hand-operated, single-lumen tube designed as a conduit for aspiration of body cavities, wounds, or surgical sites to facilitate observation and/or to clear an airway obstruction. It is not dedicated to dental, intrauterine, or lipos...
An atraumatic, invasive, single-lumen, rigid/semi-rigid tube designed as a conduit for aspiration of body cavities, wounds, or surgical sites to facilitate observation and/or clear an airway obstruction, whilst providing illumination of the site. It is not ...
An atraumatic, invasive, single-lumen, rigid/semi-rigid tube designed as a conduit for aspiration of body cavities, wounds, or surgical sites to facilitate observation and/or clear an airway obstruction, whilst providing illumination of the site. It is not ...
An atraumatic, invasive, single-lumen tube designed as a conduit for aspiration of body cavities, wounds, or surgical sites to facilitate observation and/or clear an airway obstruction, whilst providing illumination of the site. It is not dedicated to denta...
A thin, flexible tube designed to inject a contrast medium into select blood vessels of the cerebral, visceral, or peripheral vasculature during an angiographic procedure in order to facilitate the clear visualization of the vascular system of a targeted or...
A component of a rigid or flexible endoscope assembly designed as a tube through which an endoscope (e.g., hysteroscope) and endoscopic elements are introduced and assembled to create a complete operative endoscopic unit; it is also designed to function as ...
A general-purpose remote-afterloading brachytherapy applicator intended to be used to facilitate the delivery of radiation therapy treatments in a range of anatomical regions (e.g., liver, kidneys, lungs, gastrointestinal tract). It is designed for temporar...
An atraumatic, invasive, hand-operated tube designed as a conduit for irrigation and aspiration (i.e., capable of both functions) of body cavities/wounds during a surgical procedure (e.g., neurosurgery, laparoscopy), typically to facilitate observation. It ...
A device or collection of devices that includes a flexible polymer tube intended to be used primarily to transfer gametes (eggs or sperm) and/or embryos into the female reproductive tract for the purpose of assisted reproduction [e.g., intrauterine insemina...
A flexible tube intended to be percutaneously introduced for the repeated or continuous injection of local anaesthetics for preoperative, intraoperative, or postoperative regional anaesthesia and/or pain management; it may be placed in the epidural space, i...
A component of a rigid or flexible endoscope assembly designed as a tube through which an endoscope (e.g., hysteroscope) and endoscopic elements are introduced and assembled to create a complete operative endoscopic unit; it is also designed to function as ...
A flexible tube intended to be used for ureteral access to allow introduction of other instruments (e.g., endoscope, catheter) and/or for guidewire exchange during a urological procedure. It may be intended for ureteral access via transurethral and/or percu...
An atraumatic, invasive, hand-operated tube designed as a conduit for irrigation and aspiration (i.e., capable of both functions) of body cavities/wounds during a surgical procedure (typically laparoscopy), usually to facilitate observation. It is not dedic...
An atraumatic, invasive, hand-operated tube designed as a conduit for irrigation and aspiration (i.e., capable of both functions) of body cavities/wounds during a surgical procedure (e.g., neurosurgery, laparoscopy), whilst providing illumination of the sit...
An externally-worn urine drainage device intended to be worn over the penis of an incontinent male patient to channel urine, via a tube, into a collection bag. It consists of a urinary incontinence penis attachment (e.g., sheath or adhesive port), tubing, a...
An atraumatic, non-surgically invasive, hand-operated, single-lumen, rigid or semi-rigid tube designed to be introduced into the sinus cavities, through the nostrils, to function as a conduit for irrigation and aspiration (i.e., capable of both functions) o...
A flexible polymer tube intended to be used to simulate the transvaginal insertion of an assisted reproduction catheter set for embryo transfer, to assess advancement through the cervical canal and the position of the uterus. It typically consists of an inn...
A flexible tube with a pressure sensor, transducer, and/or thermistor located at its distal tip, used for intrapartum transcervical measurement of the intrauterine and amniotic pressures. It is attached at its proximal end via a signal cable to an external ...
A flexible tube intended to be used for ureteral access for the passage of other instruments (e.g., endoscope, catheter) and/or for guidewire exchange during a urological procedure. It may be intended for ureteral access via transurethral and/or percutaneou...
An implantable device intended to be used 1) to create a tunnel through which a discontinuous peripheral nerve can regenerate to bridge the proximal and distal nerve ends, 2) to encase a nerve for protection to aid in repair [e.g., to prevent ingrowth of sc...
A non-sterile, externally-worn, urine drainage device intended to be worn over the penis of an incontinent male patient to channel urine, via a tube, into a collection bag. It consists of a urinary incontinence penis attachment (e.g., sheath or adhesive por...
A sterile, flexible tube intended to be percutaneously introduced for the repeated or continuous injection of local anaesthetics for preoperative, intraoperative, or postoperative regional anaesthesia and/or pain management; it may be placed in the epidural...
A flexible tube intended to be inserted via the urethra and bladder into the ureter to gain access to the urinary tract and to provide a conduit for the passage of other instruments (e.g., endoscope, guidewire, catheter) during a urological procedure. It is...