Search

30 matching records for Tube Sheath.

GMDN Terms#

Enteral feeding/decompression tube clearing stem

46 GUDID devices

A non-sterile, sheath-covered device intended to be used to mechanically clear a clog in an in situ nasogastric, nasoenteral, gastrostomy and/or jejunostomy tube, used for feeding and/or decompression, to maintain luminal patency. It consists of a sheath an...

Urinary incontinence penis sheath/port, single-use

434 GUDID devices

A device intended to be worn on or over the penis by an incontinent patient to channel urine from the penis, via a tube, into a collection bag. It consists of a penis-worn sheath (e.g., condom-catheter) or adhesive port (e.g., glans penis attachment), and m...

Urinary incontinence penis sheath/port, single-use, non-sterile

249 GUDID devices

A non-sterile device intended to be worn on or over the penis by an incontinent patient to channel urine from the penis, via a tube, into a collection bag. It consists of a penis-worn sheath (e.g., condom-catheter) or adhesive port (e.g., glans penis attach...

Cardiac transseptal dilator

3 GUDID devices

A sterile device designed to be used with a transseptal introducer sheath to penetrate the interatrial septum to gain left-heart access during a transseptal catheterization procedure. It is typically a long, thin tube made of plastic that is curved and roun...

Surgical/emergency suction cannula, non-illuminating, reusable

5,967 GUDID devices

An atraumatic, invasive, hand-operated, single-lumen, rigid/semi-rigid tube designed as a conduit for aspiration of body cavities, wounds, or surgical sites to facilitate observation and/or to clear an airway obstruction. It is not dedicated to dental, intr...

Surgical/emergency suction cannula, non-illuminating, single-use

1,274 GUDID devices

An atraumatic, invasive, hand-operated, single-lumen, rigid/semi-rigid tube designed as a conduit for aspiration of body cavities, wounds, or surgical sites to facilitate observation and/or to clear an airway obstruction. It is not dedicated to dental, intr...

Surgical/emergency suction cannula, non-illuminating, reusable

865 GUDID devices

An atraumatic, invasive, hand-operated, single-lumen tube designed as a conduit for aspiration of body cavities, wounds, or surgical sites to facilitate observation and/or to clear an airway obstruction. It is not dedicated to dental, intrauterine, or lipos...

Surgical/emergency suction cannula, non-illuminating, single-use

84 GUDID devices

An atraumatic, invasive, hand-operated, single-lumen tube designed as a conduit for aspiration of body cavities, wounds, or surgical sites to facilitate observation and/or to clear an airway obstruction. It is not dedicated to dental, intrauterine, or lipos...

Surgical/emergency suction cannula, illuminating, single-use

64 GUDID devices

An atraumatic, invasive, single-lumen, rigid/semi-rigid tube designed as a conduit for aspiration of body cavities, wounds, or surgical sites to facilitate observation and/or clear an airway obstruction, whilst providing illumination of the site. It is not ...

Surgical/emergency suction cannula, illuminating, reusable

21 GUDID devices

An atraumatic, invasive, single-lumen, rigid/semi-rigid tube designed as a conduit for aspiration of body cavities, wounds, or surgical sites to facilitate observation and/or clear an airway obstruction, whilst providing illumination of the site. It is not ...

Surgical/emergency suction cannula, illuminating, reusable

1 GUDID devices

An atraumatic, invasive, single-lumen tube designed as a conduit for aspiration of body cavities, wounds, or surgical sites to facilitate observation and/or clear an airway obstruction, whilst providing illumination of the site. It is not dedicated to denta...

Angiographic catheter, single-use

14,618 GUDID devices

A thin, flexible tube designed to inject a contrast medium into select blood vessels of the cerebral, visceral, or peripheral vasculature during an angiographic procedure in order to facilitate the clear visualization of the vascular system of a targeted or...

Endoscope sheath, reusable

2,717 GUDID devices

A component of a rigid or flexible endoscope assembly designed as a tube through which an endoscope (e.g., hysteroscope) and endoscopic elements are introduced and assembled to create a complete operative endoscopic unit; it is also designed to function as ...

General-purpose brachytherapy system applicator, remote-afterloading

2,406 GUDID devices

A general-purpose remote-afterloading brachytherapy applicator intended to be used to facilitate the delivery of radiation therapy treatments in a range of anatomical regions (e.g., liver, kidneys, lungs, gastrointestinal tract). It is designed for temporar...

Surgical irrigation/aspiration cannula, non-illuminating, reusable

850 GUDID devices

An atraumatic, invasive, hand-operated tube designed as a conduit for irrigation and aspiration (i.e., capable of both functions) of body cavities/wounds during a surgical procedure (e.g., neurosurgery, laparoscopy), typically to facilitate observation. It ...

Assisted reproduction transfer catheter/set

506 GUDID devices

A device or collection of devices that includes a flexible polymer tube intended to be used primarily to transfer gametes (eggs or sperm) and/or embryos into the female reproductive tract for the purpose of assisted reproduction [e.g., intrauterine insemina...

Anaesthesia conduction catheter

391 GUDID devices

A flexible tube intended to be percutaneously introduced for the repeated or continuous injection of local anaesthetics for preoperative, intraoperative, or postoperative regional anaesthesia and/or pain management; it may be placed in the epidural space, i...

Endoscope sheath, single-use

384 GUDID devices

A component of a rigid or flexible endoscope assembly designed as a tube through which an endoscope (e.g., hysteroscope) and endoscopic elements are introduced and assembled to create a complete operative endoscopic unit; it is also designed to function as ...

Ureteral introduction sheath

274 GUDID devices

A flexible tube intended to be used for ureteral access to allow introduction of other instruments (e.g., endoscope, catheter) and/or for guidewire exchange during a urological procedure. It may be intended for ureteral access via transurethral and/or percu...

Surgical irrigation/aspiration cannula, non-illuminating, single-use

148 GUDID devices

An atraumatic, invasive, hand-operated tube designed as a conduit for irrigation and aspiration (i.e., capable of both functions) of body cavities/wounds during a surgical procedure (typically laparoscopy), usually to facilitate observation. It is not dedic...

Surgical irrigation/aspiration cannula, illuminating, reusable

104 GUDID devices

An atraumatic, invasive, hand-operated tube designed as a conduit for irrigation and aspiration (i.e., capable of both functions) of body cavities/wounds during a surgical procedure (e.g., neurosurgery, laparoscopy), whilst providing illumination of the sit...

Penis wearable urinal

62 GUDID devices

An externally-worn urine drainage device intended to be worn over the penis of an incontinent male patient to channel urine, via a tube, into a collection bag. It consists of a urinary incontinence penis attachment (e.g., sheath or adhesive port), tubing, a...

Paranasal sinus irrigation/aspiration cannula

53 GUDID devices

An atraumatic, non-surgically invasive, hand-operated, single-lumen, rigid or semi-rigid tube designed to be introduced into the sinus cavities, through the nostrils, to function as a conduit for irrigation and aspiration (i.e., capable of both functions) o...

Assisted reproduction transfer catheter trial

41 GUDID devices

A flexible polymer tube intended to be used to simulate the transvaginal insertion of an assisted reproduction catheter set for embryo transfer, to assess advancement through the cervical canal and the position of the uterus. It typically consists of an inn...

Intrapartum pressure monitoring catheter

41 GUDID devices

A flexible tube with a pressure sensor, transducer, and/or thermistor located at its distal tip, used for intrapartum transcervical measurement of the intrauterine and amniotic pressures. It is attached at its proximal end via a signal cable to an external ...

Ureteral sheath

41 GUDID devices

A flexible tube intended to be used for ureteral access for the passage of other instruments (e.g., endoscope, catheter) and/or for guidewire exchange during a urological procedure. It may be intended for ureteral access via transurethral and/or percutaneou...

Nerve guide, synthetic polymer, bioabsorbable

29 GUDID devices

An implantable device intended to be used 1) to create a tunnel through which a discontinuous peripheral nerve can regenerate to bridge the proximal and distal nerve ends, 2) to encase a nerve for protection to aid in repair [e.g., to prevent ingrowth of sc...

Penis wearable urinal

13 GUDID devices

A non-sterile, externally-worn, urine drainage device intended to be worn over the penis of an incontinent male patient to channel urine, via a tube, into a collection bag. It consists of a urinary incontinence penis attachment (e.g., sheath or adhesive por...

Anaesthesia conduction catheter, antimicrobial

11 GUDID devices

A sterile, flexible tube intended to be percutaneously introduced for the repeated or continuous injection of local anaesthetics for preoperative, intraoperative, or postoperative regional anaesthesia and/or pain management; it may be placed in the epidural...

Ureteral sheath

10 GUDID devices

A flexible tube intended to be inserted via the urethra and bladder into the ureter to gain access to the urinary tract and to provide a conduit for the passage of other instruments (e.g., endoscope, guidewire, catheter) during a urological procedure. It is...