Soft Tip Neti Pot Sinus Wash
SODIUM BICARBONATE, SODIUM CHLORIDE
71 matching records for V-Tip.
SODIUM BICARBONATE, SODIUM CHLORIDE
SODIUM BICARBONATE, SODIUM CHLORIDE
SODIUM BICARBONATE, SODIUM CHLORIDE
SODIUM BICARBONATE, SODIUM CHLORIDE
SODIUM BICARBONATE, SODIUM CHLORIDE
SODIUM BICARBONATE, SODIUM CHLORIDE
SODIUM BICARBONATE, SODIUM CHLORIDE
SALICYLIC ACID
SODIUM BICARBONATE, SODIUM CHLORIDE
SODIUM BICARBONATE, SODIUM CHLORIDE
External Analgesic Plaster for Removal of Corns and Calluses
SODIUM BICARBONATE, SODIUM CHLORIDE
Salicylic Acid
SALICYLIC ACID
Titanium dioxide
Titanium dioxide
Titanium Dioxide
Titanium Dioxide
Titanium Dioxide
Titanium Dioxide
Titanium Dioxide
Titanium Dioxide
Titanium Dioxide
Titanium Dioxide
Titanium Dioxide
Titanium Dioxide
20251210
20251210
20251210
20251210
20251210
20251210
20250203
20250203
20220109
20180327
2025-12-12
2025-12-11
2025-11-11
2025-07-05
2025-07-05
A hand-held component of an ultrasonic surgical system which includes a holder with controls and a surgical endpiece (tip) intended to be connected to a system transducer (not included) whereby the tip oscillates (vibrates) at high frequency in order to fra...
A hand-held component of an ultrasonic surgical system which includes a holder with controls and a surgical endpiece (tip) intended to be connected to a system transducer (not included) whereby the tip oscillates (vibrates) at high frequency in order to fra...
A hand-held component of an ultrasonic surgical system which includes a holder with controls and a surgical endpiece (tip) intended to be connected to a system transducer (not included) whereby the tip oscillates (vibrates) at high frequency in order to fra...
A sterile, hand-held component of an ultrasonic surgical system which includes a holder with controls and a surgical endpiece (tip) intended to be connected to a system transducer (not included) whereby the tip oscillates (vibrates) at high frequency in ord...
A sterile, hand-held component of an ultrasonic surgical system which includes a holder with controls and a surgical endpiece (tip) intended to be connected to a system transducer (not included) whereby the tip oscillates (vibrates) at high frequency in ord...
An insert intended to be attached to an ultrasonic dental scaling/debridement system handpiece, to transmit ultrasonic energy (e.g., 25 kHz/30 kHz) from a generator to the oral cavity for the removal of accretions from tooth surfaces during dental cleaning ...
A long, thin, metal rod designed to guide intramedullary canal devices for performing the implantation of an intramedullary nail to treat damaged bone. The rod is usually manually inserted into the canal to typically guide a surgical instrument (e.g., a rea...
A thin, non-implantable rod designed to guide the insertion of a cannulated orthopaedic implant (typically an intramedullary nail or screw) and/or surgical instrument (e.g., drill bit) during an orthopaedic procedure. It is made of metal and is available in...
A thin, non-implantable rod designed to guide the insertion of a cannulated/tubular orthopaedic implant (typically an intramedullary nail, a bone screw or femoral fixation plate) and/or surgical instrument (e.g., drill bit) during an orthopaedic procedure. ...
A thin, non-implantable rod designed to guide the insertion of a cannulated/tubular orthopaedic implant (typically an intramedullary nail, a bone screw or femoral fixation plate) and/or surgical instrument (e.g., drill bit) during an orthopaedic procedure. ...
A holder for a detachable tip that functions as part of a pneumatic dental scaling/debridement system, designed to use compressed air to generate a vibrating action at the tip to: 1) mechanically fragment and dislodge gross debris in the dental pulp canal d...
A slender, hollow, tubular, metal instrument with a blunt tip designed specifically for irrigation of the root canal of a tooth during an endodontic procedure. Sometimes referred to as a root canal irrigation cannula, it is typically attached to a dental sy...
A thin, non-implantable rod designed to guide the insertion of a cannulated orthopaedic implant (typically an intramedullary nail or screw) and/or surgical instrument (e.g., drill bit) during an orthopaedic procedure. It is made of metal and is available in...
A hand-held manual device designed to hold and operate a compatible ophthalmic surgical instrument tip (typically scissors, forceps). It is typically in the form of a conventional handle with a connector that secures the inserted tip, and has a manually-ope...
A sterile, long, thin, metal rod designed to guide intramedullary canal devices for performing the implantation of an intramedullary nail to treat damaged bone. The rod is usually manually inserted into the canal to typically guide a surgical instrument (e....
A flexible tube with specific tip configurations designed to enter the left or right ventricle to perform diagnostic haemodynamic/angiographic procedures with contrast media. The distal tip may have an end hole and/or several side holes. The tube is introdu...
A sterile, hand-held, pneumatically-powered device designed to hold and operate a compatible ophthalmic surgical instrument tip (e.g., scissors, forceps). It is typically in the form of a conventional handle with a connector that secures the inserted tip, a...
A hand-held instrument designed to manually attach or detach a handpiece tip (blade) from the handpiece of an ultrasonic surgical system. It is typically formed with a socket that is placed over the handpiece tip and rotated by the operator to tighten or lo...
An extremely thin, wire-like, manual surgical instrument designed for traversing and exploring urethral strictures and/or dilating the urethra, introduced directly or through an appropriately-threaded urethral catheter. The tip of the device can be bent or ...
A hand-held manual device designed to hold and operate a compatible ophthalmic surgical instrument tip (typically scissors, forceps). It is typically in the form of a conventional handle with a connector that secures the inserted tip, and has a manually-ope...
A removable attachment to an ultrasonic surgical system handpiece intended to contain the flow of coolant liquid, supplied through the handpiece, over the ultrasonic surgical system handpiece tip; the coolant is intended to prevent overheating of the tip du...
A non-sterile semi-flexible device intended to be attached to the distal end of a dental suction tip and held between the teeth and cheek of a patient, to allow for hands-free suction during a dental procedure. It is typically a flat disk made of synthetic ...
A sterile hand-held instrument designed to manually attach or detach a handpiece tip (blade) from the handpiece of an ultrasonic surgical system. It is typically formed with a socket that is placed over the handpiece tip and rotated by the operator to tight...
A hand-held component of an ultrasonic surgical system intended to be connected to a system holder/tip or combined holder/tip, whereby it is designed to convert high frequency electrical current from a generator into an ultrasonic oscillation, to fragment h...
An electronic endoscope with a flexible distal tip, combined with an ultrasound probe, intended for the visual examination, treatment, and ultrasonic imaging of the abdominal/retroperitoneal cavity and its organs. It is inserted through an incision made in ...
A non-sterile hand-operated surgical instrument intended for the implantation of a capsular tension ring (CTR) into the crystalline lens capsular bag during intraocular lens (IOL) surgery (e.g., cataract extraction). It typically consists of a tubular dista...
A hand-held component of an ultrasonic surgical system intended to guide/direct the tip of the system’s holder/tip (not included) which oscillates (vibrates) on hard tissue (e.g., bone) during open or minimally-invasive surgery. It typically has a tubular f...
A sterile, sharp bevel-edged, hollow tubular metal instrument designed to be used: 1) as a bipolar electrode for real-time bioimpedance-based prediction of the needle tip location; and 2) for lumbar puncture/intrathecal injection. The needle and an included...
A hand-held component of an ultrasonic surgical system intended to convert high frequency electrical current into an ultrasonic oscillation, and transfer the energy to an attachable tip, to mechanically fragment and cut both bone and soft-tissue cells upon ...
A small diameter tube intended to be placed over the shaft of a pipette to facilitate ejection of a pipette tip after use. The distal end of the sleeve pushes on the connected pipette tip to remove it. It is typically made of plastic materials. This is a re...