A device intended to be used to couple together any type of powered ventilator to any kind of breathing circuit system, making them compatible for use. By using this device it is then possible to use alternative combinations of ventilator and breathing circ...
A device designed to connect a respiratory circuit (e.g., an anaesthesia breathing circuit or ventilator breathing circuit) or a resuscitator to an endotracheal (ET) tube, to enable increased mobility at the patient end of the circuit or connections. It mos...
A device designed to connect a respiratory circuit (e.g., an anaesthesia breathing circuit or ventilator breathing circuit) or a resuscitator to an endotracheal (ET) tube, to enable increased mobility at the patient end of the circuit or connections. It mos...
A device designed to connect a respiratory circuit (e.g., an anaesthesia breathing circuit or ventilator breathing circuit) or a resuscitator to an endotracheal (ET) tube, to enable increased mobility at the patient end of the circuit or connections. It mos...
A portable, mains electricity (AC-powered) device designed to be integrated within the expiratory limb of a ventilator breathing circuit to remove excess moisture through cooling and condensing, whilst also reheating the dried gases to an appropriate ventil...
A device that includes a transducer intended to detect the movement of gases in a breathing circuit, and convert this into an electrical signal for relay to a ventilator (e.g., adult/paediatric/neonatal ventilators, anaesthesia system ventilators). It is co...
A sterile device that includes a transducer intended to detect the movement of gases in a breathing circuit, and convert this into an electrical signal for relay to a ventilator (e.g., adult/paediatric/neonatal ventilators, anaesthesia system ventilators). ...
An assembly of devices that includes a breathing circuit and a respiratory mask designed to conduct air or oxygen (O2) enriched gases and additional gases [e.g., nitrous oxide (N2O), halogenated gases] from a ventilator to a patient during noninvasive venti...
A non-sterile device intended to be integrated within a breathing circuit (e.g., ventilator or respirator breathing circuit) to collect the condensate which accumulates typically during heated humidification. It includes a fluid collection container with in...
A non-sterile device intended to be integrated within a breathing circuit (e.g., ventilator breathing circuit) to collect the condensate which accumulates typically during heated humidification. It includes a fluid collection container with input and output...
A device used to connect a respiratory circuit (e.g., an anaesthesia breathing circuit or ventilator breathing circuit) or a resuscitator to an endotracheal (ET) tube, to enable increased mobility at the patient end of the circuit or connections. It most co...
A device used to connect a respiratory circuit (e.g., an anaesthesia breathing circuit or ventilator breathing circuit) or a resuscitator to an endotracheal (ET) tube, to enable increased mobility at the patient end of the circuit or connections. It most co...
An assembly of devices designed to conduct air or oxygen (O2) enriched gases and additional gases [e.g., nitrous oxide (N2O), halogenated gases] from a ventilator to a patient artificial airway/respiratory mask (not included). It includes breathing tubes, a...
An assembly of devices designed to conduct air or oxygen (O2) enriched gases and additional gases [e.g., nitrous oxide (N2O), halogenated gases] from a ventilator to a patient. It includes breathing tubes, a Y-piece connector, and provides connections for d...
An assembly of devices designed to conduct air or oxygen (O2) enriched gases and additional gases [e.g., nitrous oxide (N2O), halogenated gases] from a ventilator, or other air-delivery therapeutic device such as a mechanical insufflator/exsufflator, to a p...
A device designed primarily to hold the breathing circuit tubing that carries gases from a ventilator and/or anaesthesia system to and from the patient. It is typically fixed to the ventilator/anaesthesia system, but can also be fixed to the patient's bed o...
A non-sterile assembly of devices designed to conduct air or oxygen (O2) enriched gases and additional gases [e.g., nitrous oxide (N2O), halogenated gases] from a ventilator to a patient. It includes breathing tubes, a Y-piece connector, and provides connec...
A non-sterile elastomeric reservoir sac intended to store breathing gas during the respiratory cycle. The breathing bag may be on the inspiratory or expiratory limb of a breathing circuit depending on the breathing circuit design. It may also function as a ...
A sterile length of tube with valves intended to create a closed three-way connection between an endotracheal tube, a ventilator/anaesthesia unit, and a suction pump to eliminate the need to disconnect the breathing circuit for secretion suctioning. The val...
A non-sterile elastomeric reservoir sac intended to store breathing gas during the respiratory cycle. The breathing bag may be on the inspiratory or expiratory limb of a breathing circuit depending on the breathing circuit design. It may also function as a ...
A non-sterile device used to regulate the maximum pressure level in a circuit or system (typically containing gas) where it is essential not to exceed a pre-set maximum pressure. Should this pressure level be exceeded, this device will automatically open an...
A non-sterile device used to regulate the maximum pressure level in a circuit or system (typically containing gas) where it is essential not to exceed a pre-set maximum pressure. Should this pressure level be exceeded, this device will automatically open an...
A device designed to provide mandatory breathes to ventilator patients to supplement the spontaneous respiratory rate. It is typically constructed of durable materials and consists of tubing and one-way valves. It will be used as an accessory on older venti...
A device designed to provide mandatory breathes to ventilator patients to supplement the spontaneous respiratory rate. It is typically constructed of plastics and consists of tubing and one-way valves. It will be used as an accessory on older ventilators wi...
An assembly of devices designed to conduct medical gases from the fresh gas supply outlet of an anaesthesia unit/workstation to the patient, typically connecting the patient, a ventilator/ventilation bag, carbon dioxide (CO2) absorber, and a monitor. It typ...
A non-sterile assembly of devices designed to conduct medical gases from the fresh gas supply outlet of an anaesthesia unit/workstation to the patient typically connecting the patient, a ventilator/ventilation bag, carbon dioxide (CO2) absorber, and a monit...
A non-sterile device intended to be integrated within a ventilator breathing circuit and used in conjunction with a heated respiratory humidifier (from which it draws its power) to maintain the temperature of inspiratory gasses during ventilation of an adul...
A non-sterile device intended to be integrated within a ventilator breathing circuit and used in conjunction with a heated respiratory humidifier (from which it draws its power) to maintain the temperature of inspiratory gasses during ventilation of an infa...
A sterile assembly of devices designed to conduct medical gases from the fresh gas supply outlet of an anaesthesia unit/workstation to the patient, typically connecting the patient, a ventilator/ventilation bag, carbon dioxide (CO2) absorber, and a monitor....
A hollow tubular device made of durable materials (e.g., rubber, silicone) intended to be used to conduct breathing gases during the respiratory cycle, typically during anaesthesia or ventilation. It is intended to function as part of, or in association wit...