A device designed primarily to hold the breathing circuit tubing that carries gases from a ventilator and/or anaesthesia system to and from the patient. It is typically fixed to the ventilator/anaesthesia system, but can also be fixed to the patient's bed o...
A device designed to provide mandatory breathes to ventilator patients to supplement the spontaneous respiratory rate. It is typically constructed of durable materials and consists of tubing and one-way valves. It will be used as an accessory on older venti...
A device designed to provide mandatory breathes to ventilator patients to supplement the spontaneous respiratory rate. It is typically constructed of plastics and consists of tubing and one-way valves. It will be used as an accessory on older ventilators wi...
A length of reinforced colour-coded flexible tubing produced according to ISO5359 intended to conduct compressed oxygen (O2) from an O2 terminal unit or O2 cylinder to a medical device that functions with O2 (e.g., ventilators, anaesthesia unit, analgesia u...
A length of reinforced colour-coded flexible tubing produced according to ISO5359 intended to conduct compressed medical air from a medical air cylinder/terminal unit to a medical device that functions with medical air (e.g., ventilator, anaesthesia unit, a...
A length of flexible tube intended to conduct compressed oxygen (O2) from an O2 terminal unit or O2 cylinder to a medical device that functions with O2 (e.g., ventilators, anaesthesia units, anaesthesia systems, analgesia units and other O2 dependent respir...
A length of reinforced colour-coded flexible tubing produced according to ISO5359 intended to conduct compressed nitrous oxide (N2O) from an N2O terminal unit or N2O cylinder to a medical device that functions with N2O (e.g., ventilator, anaesthesia unit, a...
A length of flexible tube intended to conduct compressed medical air from a medical air cylinder/terminal unit to a medical device that functions with medical air (e.g., ventilators, anaesthesia units, anaesthesia systems, suctions systems and other medical...
A length of reinforced colour-coded flexible tubing produced according to ISO5359 and intended to conduct compressed carbon dioxide (CO2) from a CO2 terminal unit or CO2 cylinder to a medical device that functions with CO2 (e.g., ventilator, insufflation sy...
A length of reinforced colour-coded flexible tubing produced according to ISO5359 intended to conduct compressed oxygen (O2) from an O2 terminal unit or O2 cylinder to a medical device that functions with O2 (e.g., ventilators, anaesthesia unit, analgesia u...
A length of flexible tube intended to conduct compressed nitrous oxide (N2O) from an N2O terminal unit or N2O cylinder to a medical device that functions with N2O (e.g., ventilators, anaesthesia units, anaesthesia systems, analgesia units and other N2O depe...
"A length of reinforced colour-coded flexible tubing produced according to ISO5359 intended to conduct compressed medical air from a medical air cylinder/terminal unit to a medical device that functions with medical air (e.g., ventilator, anaesthesia unit, ...
"A length of reinforced colour-coded flexible tubing produced according to ISO5359 intended to conduct compressed oxygen (O2) from an O2 terminal unit or O2 cylinder to a medical device that functions with O2 (e.g., ventilators, anaesthesia unit, analgesia ...
A length of reinforced colour-coded flexible tubing produced according to ISO5359 intended to conduct a specific compressed medical gas mixture (e.g., helium/oxygen, nitrous oxide/oxygen mixture) from a specific terminal unit or cylinder to an appropriate r...
"A length of reinforced colour-coded flexible tubing produced according to ISO5359 intended to conduct compressed nitrous oxide (N2O) from an N2O terminal unit or N2O cylinder to a medical device that functions with N2O (e.g., ventilator, anaesthesia unit, ...
"A length of reinforced colour-coded flexible tubing produced according to ISO5359 and intended to conduct compressed carbon dioxide (CO2) from a CO2 terminal unit or CO2 cylinder to a medical device that functions with CO2 (e.g., ventilator, insufflation s...
"A length of reinforced colour-coded flexible tubing produced according to ISO5359 intended to conduct a specific compressed medical gas mixture (e.g., helium/oxygen, nitrous oxide/oxygen mixture) from a specific terminal unit or cylinder to an appropriate ...
A mains electricity (AC-powered) device designed to heat and humidify air/oxygen inspired by a patient to help maintain the mucous membranes of the respiratory tract typically during periods of prolonged respiratory support/therapy (e.g., mechanical ventila...
A device designed to detect the presence and determine the concentration of oxygen (O2) by paramagnetic, electrochemical, or other technique. The device is typically used as a component of an oxygen monitor or a patient monitoring device/system that determi...
A mains electricity (AC-powered) device, which may include internal rechargeable batteries, intended for the delivery of precise amounts of nitric oxide (NO), also known as nitrogen monoxide, to the respiratory tract of neonate, paediatric, and adult patien...
A non-sterile, flexible, form-shaped device designed to be placed over the nose and mouth to deliver oxygen (O2) to a patient's airway, and to sample exhaled respiratory gases for monitoring the patient’s ventilatory status. It includes exhaled air sampling...
A battery-powered instrument designed to continuously measure the concentration of oxygen (O2) inspired by a patient in a respiratory maintenance/therapy setting (e.g., O2 in an anaesthesia or ventilator breathing circuit, oxygen tent, oxygen therapy device...
A collection of devices used to quickly deliver radioaerosol to a patient for ventilatory pulmonary scintigraphy. It is used with an aerosol pump/nebulizer or a compressed air line to generate the radioactive aerosol, and a lead (Pb) protective container to...
A mains electricity (AC-powered) instrument designed to continuously measure the concentration of oxygen (O2) inspired by a patient in a respiratory maintenance/therapy setting (e.g., O2 in an anaesthesia or ventilator breathing circuit, oxygen tent, oxygen...
A non-sterile device intended to enhance the capture of exhaled end-tidal carbon dioxide (EtCO2) for evaluation of a patient's ventilatory, circulatory, or metabolic status, typically during the administration of anaesthesia. It is an adhesive, dome-like ad...
An assembly of devices dedicated to the short-term delivery of precise amounts of nitric oxide (NO), also known as nitrogen monoxide, to the respiratory tract of patients for the treatment of severe respiratory failure, particularly when a primary delivery ...
A collection of sterile devices intended to be used with a lung donor-organ preservation/evaluation system. It typically consists of a lung chamber with tubing and a fluid reservoir, oxygenator, leukocyte filter, pressure sensors and a connection for a vent...
A collection of sterile devices intended to support and provide continuous physiologic organ perfusion to a donated lung(s) during its preservation, evaluation, and transport in a lung donor-organ preservation/transport system from the donor to the receiver...