A device in the form of a small attachment intended to be fitted to the working channel (including biopsy port) of an endoscope to enable access for, and/or exchange of, an endoscopic device while minimizing leakage of liquids and gasses during an endoscopi...
A sterile device intended to be fitted over the working channel access port of an endoscope to minimize leakage of liquids and gases through the working channel, while permitting entry of endoscopic devices. It is typically a small plastic Luer attachment w...
A device in the form of a small attachment intended to be fitted to the working channel (including biopsy port) of an endoscope to enable access for, and/or exchange of, an endoscopic device while minimizing leakage of liquids and gasses during an endoscopi...
A collection of sterile devices intended to be fitted to multiple endoscope working channels/ports to enable an endoscope operator control the function of the working channels/ports and prevent retrograde flow of fluids, gases, and other materials. It typic...
A non-sterile, non-steerable, multi-luminal, flexible tube intended to function as a housing for a compatible flexible endoscope and endoscopic tool(s), to facilitate introduction of the endoscope, and provide independent working channels/insufflation ports...
A rigid, hand-held manual surgical instrument designed to be introduced through a laparoscope/laparoscopic port for: 1) atraumatic grasping/clamping of soft tissues (e.g., gallbladder); and 2) access adjacent to the site of clamping (e.g., during laparoscop...
A rigid, hand-held manual surgical instrument designed to be introduced through the working channel of an endoscope and/or an endoscopic port (e.g., laparoscopic port) primarily for grasping and manipulating tissues during endoscopic surgery. It has proxima...
A component of a rigid or flexible endoscope assembly designed as a tube through which an endoscope (e.g., hysteroscope) and endoscopic elements are introduced and assembled to create a complete operative endoscopic unit; it is also designed to function as ...
A component of a rigid or flexible endoscope assembly designed as a tube through which an endoscope (e.g., hysteroscope) and endoscopic elements are introduced and assembled to create a complete operative endoscopic unit; it is also designed to function as ...
A rigid, hand-held manual surgical instrument designed to be introduced through the working channel of an endoscope and/or an endoscopic port (e.g., laparoscopic port) primarily for grasping and manipulating tissues during endoscopic surgery. It has proxima...
An endoscope with a flexible inserted portion intended for endoscopic procedures of the airways and tracheobronchial tree (i.e., bronchoscopy). It typically consists of a handle portion and an insertion tube which includes working channels and a distal came...
A sterile endoscope with a flexible inserted portion intended for endoscopic procedures of the airways and tracheobronchial tree (i.e., bronchoscopy). It typically consists of a handle portion and an insertion tube which includes working channels and a dist...
An endoscope with a flexible inserted portion intended for endoscopic procedures of the airways and tracheobronchial tree (i.e., bronchoscopy). It typically consists of a handle portion and an insertion tube which includes working channels and a distal came...
A rigid, hand-held manual surgical instrument designed to be introduced through the working channel of an endoscope and/or an endoscopic port (e.g., laparoscopic port) primarily for grasping and manipulating tissues during endoscopic surgery. It has proxima...
An endoscope with a rigid inserted portion intended for the visual examination and treatment of the larynx/oropharynx. It is inserted into the body through the mouth during ear/nose/throat (ENT) procedures. Anatomical images are transmitted to the user thro...
An endoscope with a slender rigid inserted portion intended to be used to perform a resection (i.e., the electrosurgical removal of tissue within an organ). It is typically used for the transurethral resection of the prostate (TURP) for the treatment of ben...
A hollow dilator with a tapered distal end intended to enable the gentle insertion of a larger laparoscopic access cannula, necessary when significantly increasing the working access port's lumen, e.g., from 10 to 20 mm diameter. It is commonly used in mini...
A device intended to be used in combination with a compatible flexible endoscope to collect cells of the mucosa for pathological diagnosis during endoscopy. It is inserted through the working channel of the endoscope and consists of a flexible insertion por...
An endoscope with a rigid inserted portion intended for the visual examination and treatment of the larynx/oropharynx. It is inserted into the body through the mouth during ear/nose/throat (ENT) procedures. Anatomical images are transmitted to the user by t...
A hand-held, ophthalmic surgical instrument, constructed as a one-piece handle with trephine (not an exchangeable component) that is manually rotated with downward pressure by a surgeon in order to cut and remove circular pieces of corneal tissue (corneal b...
A gas-regulating component of a medical gas (e.g., carbon dioxide, oxygen, nitrous oxide, gas mixtures) cylinder to lower high, variable gas pressure to a lower, constant working pressure. It includes a cylinder shut-off switch (i.e., cylinder valve), regul...
A rigid, hand-held, manual surgical instrument with a sharp tip designed for direct penetration of skin and soft tissues to access an endoscopic surgical site (e.g., laparoscopic), without need of a traditional insertion conduit, where it is intended to gra...
An endoscope with a flexible inserted portion intended for the visual examination of some or all of the ear (external, middle and inner), nasal passages, paranasal sinuses, pharynx, and/or larynx. It is inserted into the body through the appropriate natural...
A gas-regulating component of a medical gas (e.g., carbon dioxide, oxygen, nitrous oxide, gas mixture) cylinder to reduce high, variable gas pressure to a lower, constant working pressure. It typically includes a cylinder shut-off switch (i.e., cylinder val...
An endoscope with a rigid inserted portion intended for the observation and treatment of the eyeball and related structures. It is inserted into the eye during procedures such as endoscopic vitreoretinal surgery and glaucoma/cataract surgery. Anatomical ima...
A sterile, hand-held, manual surgical instrument intended to be inserted through the working channel of a hysteroscope to cut and remove uterine lesions (e.g., polyps), and may in addition be used to obtain a mucosal biopsy. It consists of a distal cannula ...
An endoscope with a flexible inserted portion intended for the visual examination of some or all of the ear (external, middle and inner), nasal passages, paranasal sinuses, pharynx, and/or larynx. It is inserted into the body through the appropriate natural...
An endoscope with a flexible inserted portion intended for the visual examination of the upper airway structures which include the nasal passages, nasopharynx, oropharynx, and the larynx. It is inserted into the body through the mouth or a nostril and can b...
A device intended to be used in combination with a compatible flexible endoscope to collect cells of the mucosa for pathological diagnosis during endoscopy. It is inserted through the working channel of the endoscope and consists of a flexible insertion por...
An endoscope with a rigid inserted portion intended to be used in plastic surgery for reconstructive operations, the suction of subcutaneous tissue, or vein harvesting (e.g., for implantation as a coronary bypass graft). It is inserted percutaneously into t...