Search

19 matching records for inFlow Device.

GMDN Terms#

Endoscope air/water valve, single-use

79 GUDID devices

A device intended to be fitted to an endoscope air/water channel to enable the operator to control inflow of medical gases [i.e., air, carbon dioxide (CO2)] for insufflation, and/or water for irrigation, whilst preventing backflow. It is in the form of an a...

Endoscopic procedure air/water valve, single-use

74 GUDID devices

A sterile device intended to be fitted to an endoscope air/water channel to enable the operator to control inflow of medical gases [i.e., air, carbon dioxide (CO2)] for insufflation, and/or water for irrigation, whilst preventing backflow. It is in the form...

Endoscopic procedure air/water valve, reusable

82 GUDID devices

A non-sterile device intended to be fitted to an endoscope air/water channel to enable the operator to control inflow of medical gases [i.e., air, carbon dioxide (CO2)] and/or water whilst preventing backflow. It is in the form of an attachable valve with o...

Endoscopic suction valve, reusable

54 GUDID devices

A non-sterile device intended to be fitted to an endoscope suction channel to enable the operator to control suction whist preventing inflow of air. It is in the form of an attachable valve that controls (opens/closes) the suction channel. This is a reusabl...

Endoscope suction valve, single-use

17 GUDID devices

A device intended to be fitted to an endoscope suction channel to enable the operator to control suction whist preventing inflow of air. It is in the form of an attachable valve that controls (opens/closes) the suction channel. This is a single-use device.

Endoscopic suction valve, single-use, sterile

12 GUDID devices

A sterile device intended to be fitted to an endoscope suction channel to enable the operator to control suction whist preventing inflow of air. It is in the form of an attachable valve that controls (opens/closes) the suction channel. This is a single-use ...

Endoscopic suction valve, single-use, non-sterile

11 GUDID devices

A non-sterile device intended to be fitted to an endoscope suction channel to enable the operator to control suction whist preventing inflow of air. It is in the form of an attachable valve that controls (opens/closes) the suction channel. This is a single-...

Endoscope suction valve, reusable

9 GUDID devices

A device intended to be fitted to an endoscope suction channel to enable the operator to control suction whist preventing inflow of air. It is in the form of an attachable valve that controls (opens/closes) the suction channel. This is a reusable device.

Endoscope air/water valve, reusable

5 GUDID devices

A device intended to be fitted to an endoscope air/water channel to enable the operator to control inflow of medical gases [i.e., air, carbon dioxide (CO2)] and/or water whilst preventing backflow. It is in the form of an attachable valve with one or more s...

Endoscopic suction valve, single-use

5 GUDID devices

A device intended to be fitted to an endoscope suction channel to enable the operator to control suction whist preventing inflow of air. It is in the form of an attachable valve that controls (opens/closes) the suction channel. This is a single-use device.

Endoscopic irrigation/aspiration foot-pedal

3 GUDID devices

A manual, foot-operated device designed to be used in conjunction with a dedicated irrigation tubing set and a disposable syringe to facilitate displacement of the syringe plunger for irrigation of an endoscopic site. It is intended to house the syringe whi...

Limb plethysmograph strain transducer

2 GUDID devices

A non-sterile, hoop-like device intended to be wrapped around a limb or digit and used in conjunction with a limb plethysmograph (not included) to determine volume variations in the extremities (e.g., legs, toes, arms, fingers) as modified by the circulatio...

Plethysmography strain transducer

1 GUDID devices

A hoop-like device intended to be wrapped around a limb or digit and used in conjunction with a limb plethysmograph (not included) to determine volume variations in the extremities (e.g., legs, toes, arms, fingers) as modified by the circulation of blood th...

Colonic lavage kit, non-surgical

79 GUDID devices

A collection of non-sterile devices intended to be used with a colonic lavage system/unit for the administration of an irrigation solution (e.g., saline solution) via the rectum, for the non-surgical irrigation, cleansing, and evacuation of debris from the ...

Colonic lavage kit, surgical

4 GUDID devices

A collection of sterile devices intended to be used during open colorectal surgery (bowel resection) to irrigate the colon above (proximal to) the site of a lesion/blockage, prior to surgical anastomosis, when preoperative preparation of the colon has not b...

Blood pressure cuff inflation regulator

3 GUDID devices

A mains-electricity (AC-powered) device intended to interface between an air compressor and a vascular cuff to regulate rapid inflation of the cuff during procedures to assess vascular health (e.g., venous insufficiency, maximum venous outflow, arterial inf...

Hysteroscopic/cystoscopic distention tubing set

1 GUDID devices

A collection of noninvasive, flexible, polymer tube segments with associated items (e.g., connectors, drainage bag, drape) intended to be used with an appropriate endoscope (hysteroscope, cystoscope) to manage the inflow and outflow of distension fluids dur...