A copy of a final femoral stem prosthesis designed to be used for trial reductions during hip arthroplasty to judge the correct offset, leg-length, and range of motion of the final femoral prosthesis to be implanted. It is one of a set, or a set, of graduat...
A copy of a final femoral head prosthesis designed to be used for trial reductions during hip arthroplasty to judge the correct size, and to help achieve the desired offset, leg-length, and range of motion of the final prosthesis to be implanted. It is one ...
A copy of a final transfemoral amputation tissue-reinforcement implant intended to be used during orthopaedic surgery to accurately size a transfemoral amputation tissue-reinforcement implant (medullary canal rod and bulb) prior to implantation, following a...
A hand-held manual surgical instrument designed to connect to and hold an orthopaedic implant (e.g., bone screw, bone graft) or trial implant to facilitate guidance, gauging, and monitoring of the implant or trial implant during the orthopaedic surgical int...
A sterile hand-held manual surgical instrument designed to connect to and hold an orthopaedic implant or trial implant to facilitate guidance, gauging, and monitoring of the implant or trial implant during the orthopaedic surgical intervention. The instrume...
A copy of a final reverse shoulder prosthesis cup designed to be used before primary or revision implant surgery to validate the proper size of the permanent prosthesis required by the patient and to ensure its proper orientation and positioning. It is inte...
A hand-held manual surgical instrument designed to connect to and hold an implant (e.g., bone screw, bone graft), trial implant, or implantable device sizer/template (e.g., glenoid defect sizer, hearing implant template) to facilitate guidance, gauging/sizi...
A hand-held manual surgical instrument designed to connect to and hold an implant (e.g., bone screw, bone graft), trial implant, or implantable device sizer/template (e.g., glenoid defect sizer, hearing implant template) to facilitate guidance, gauging/sizi...
A hand-held manual surgical instrument designed to connect to and hold an orthopaedic implant (e.g., bone screw, bone graft), trial implant, or sizer (e.g., glenoid defect sizer) to facilitate guidance, gauging/sizing, and/or monitoring of the held device d...
A hand-held manual surgical instrument designed to connect to and hold an orthopaedic implant (e.g., bone screw, bone graft), trial implant, or sizer (e.g., glenoid defect sizer) to facilitate guidance, gauging/sizing, and/or monitoring of the held device d...
A cylindrical rod that simulates an orthopaedic bone nail designed to be placed into the proximal end of the intramedullary canal of a long bone (e.g., through the femoral head) to act as a decisive reference point for the subsequent drilling and insertion ...
A copy of a final acetabular prosthesis designed to be used for trial reductions during hip arthroplasty to judge the correct size and position of the final acetabular prosthesis to be implanted. It is one of a set, or a set, of graduated sizes, is typicall...
A copy of a final acetabular prosthesis designed to be used for trial reductions during hip arthroplasty to judge the correct size and position of the final acetabular prosthesis to be implanted. It is one of a set, or a set, of graduated sizes, is typicall...
A copy of a final elbow radius prosthesis designed to be used for trial reductions during elbow arthroplasty to help determine the correct size, length, and range of motion of the final prosthesis to be implanted. It is one of a set, or a set, of graduated ...
A copy of a final humerus prosthesis designed to be used for trial reductions during elbow arthroplasty to judge the correct size, length, condyle positioning, and range of motion of the final prosthesis to be implanted. It is one of a set, or a set, of gra...
A copy of a final ulna prosthesis designed to be used for trial reductions during elbow arthroplasty to judge the correct sizing, length, and range of motion of the final prosthesis to be implanted. It is one of a set, or a set, of graduated sizes and is ty...
A copy of a final acetabular cup prosthesis designed to be used for trial reductions during hip arthroplasty to judge the correct size and position of the final acetabular prosthesis to be implanted. It is one of a set, or a set, of graduated sizes, is typi...
An electrically-powered, external component of a spinal cord/peripheral nerve percutaneous analgesic electrical stimulation system intended to be used during a trial period (
A sterile copy of a final acetabular cup prosthesis designed to be used for trial reductions during hip arthroplasty to judge the correct size and position of the final acetabular prosthesis to be implanted. It is one of a set, or a set, of graduated sizes,...
An invasive, electrically-insulated wire with a distal electrode intended to be introduced into the epidural space of the spinal cord and/or in/near a peripheral nerve (e.g., lumbar, truncal, in a limb) for percutaneous wired transmission of electrical impu...
An orthopaedic device designed to limit the depth of insertion of a surgical instrument (e.g., a drill bit or a reamer), a trial implant, or an implant. It may be used as a stand-alone device or it may be attached to another device to control the insertion ...
An electrically-powered, external (noninvasive) component of a spinal cord/peripheral nerve implantable analgesic electrical stimulation system intended to generate electrical impulses, for wireless (transcutaneous) transmission, to an implantable lead (sit...
A copy of a final spinal prosthesis, graft, or other implantable spinal device (e.g., may include intervertebral disc prosthesis, spinal cage, spinal hook) used to validate the proper size of the permanent implant required by the patient, to determine its a...
A device designed to limit the depth of insertion of a surgical instrument (e.g., a drill bit or a reamer), a trial implant, or an implant. It may be used as a stand-alone device or it may be attached to another device to control insertion depth, typically ...
A copy of a dental implant abutment intended to be used intraorally during dental implant restorative procedures to reproduce the characteristics of an abutment (e.g., angle, diameter, transmucosal or cementable area height) to facilitate selection of an ap...
A device designed to limit the depth of insertion of a surgical instrument (e.g., a drill bit or a reamer), a trial implant, or an implant. It may be used as a stand-alone device or it may be attached to another device to control insertion depth, typically ...
A copy of a final humeral head prosthesis designed to be used before primary or revision implant surgery to validate the proper size of the permanent prosthesis required by the patient, to ensure its proper orientation and positioning, and to verify that th...
A manual surgical instrument designed to be inserted into the medullary canal of the femur as a guide to the size of orthopaedic reamer to be used prior to introduction of a femoral implant (e.g., transfemoral prosthesis intrafemoral implant, intramedullary...
A sterile copy of a final humeral head prosthesis designed to be used before primary or revision implant surgery to validate the proper size of the permanent prosthesis required by the patient, to ensure its proper orientation and positioning, and to verify...
An electrically-powered, external component of a spinal cord/peripheral nerve implantable analgesic electrical stimulation system intended to be used during a trial period (< 30 days) to noninvasively test operating parameters prior to implantation of the p...