Kit for the Preparation of Technetium Tc 99m Medronate

Manufacturer
Cardinal Health 414, LLC
Effective date
2025-09-08
Label type
HUMAN PRESCRIPTION DRUG LABEL
Version
5
Source
full-release
Hydrated at
2026-05-31 21:42:17

Label at a glance#

ProductKit for the Preparation of Technetium Tc 99m Medronate
Active ingredientTECHNETIUM TC-99M MEDRONATE
Label structure13 sections

Indications and uses

Technetium Tc 99m medronate may be used as a bone imaging agent to delineate areas of altered osteogenesis.

Dosage and administration

After preparation with oxidant-free sodium pertechnetate Tc 99m injection the suggested dose range of technetium Tc 99m medronate injection in the average patient (70 kg) is 370 MBq to 740 MBq (10 mCi to 20 mCi) given intravenously. Imaging post injection is optimal at 1 to 4 hours. The patient dose should be measured by a suitable radioactivity calibration system immediately prior to administration. Parenteral dr...

Label contents#

Full prescribing information#

DESCRIPTION

DESCRIPTION SECTION

Each reaction vial contains a sterile, nonpyrogenic, nonradioactive lyophilized mixture of 20 mg medronic acid, 1 mg ascorbic acid, 0.13 mg (minimum) stannous fluoride, SnF2 and 0.38 mg total tin, maximum (as stannous fluoride, SnF2).

The pH is adjusted with sodium hydroxide or hydrochloric acid to 6.5 (6.3 to 6.7) prior to lyophilization. The vial does not contain a preservative. The contents of the vial are lyophilized and sealed under nitrogen at the time of manufacture.

The pH of the reconstituted product is 5.4 to 6.8.

The structure of medronic acid is given below:

Structure of Medronic Acid
Structure of Medronic Acid

The precise structure of technetium Tc 99m medronate is unknown at this time.

When sterile, pyrogen-free sodium pertechnetate Tc 99m injection is added to the vial, the diagnostic agent technetium Tc 99m medronate is formed for administration by intravenous injection.

PHYSICAL CHARACTERISTICS

SPL UNCLASSIFIED SECTION

Technetium Tc 99m decays by isomeric transition with a physical half-life of 6.02 hours.1 The principal photon that is useful for detection and imaging studies is shown in Table 1.

Table 1
1 Kocher, David C: Radioactive Decay Data Tables, DOE/TlC-11026, 108, 1981

Principal Radiation Emission Data

Radiation

Mean % per
Disintegration

Mean Energy
(keV)

Gamma-2

89.07

140.5

External Radiation

SPL UNCLASSIFIED SECTION

The specific gamma ray constant for Tc 99m is 0.78 R/ hour-millicurie at 1 cm. The first half-value layer is 0.017 cm lead (Pb). A range of values for the relative attenuation of the radiation emitted by this radionuclide that results from interposition of various thicknesses of Pb is shown in Table 2. To facilitate control of the radiation exposure from millicurie amounts of this radionuclide, the use of a 0.25 cm thickness of Pb will attenuate the radiation emitted by a factor of about 1,000.

Table 2

Radiation Attenuation by Lead Shielding

Shield Thickness
(Pb) cm

Coefficient
of Attenuation

0.017

0.5

0.08

10-1

0.16

10-2

0.25

10-3

0.33

10-4

To correct for physical decay of technetium Tc 99m, the fractions that remain at selected intervals after the time of calibration are shown in Table 3.

Table 3
* Calibration Time

Physical Decay Chart: Tc 99m, half-life 6.02 hours

Hours

Fraction
Remaining

Hours

Fraction
Remaining

0*

100.0

7

0.447

1

0.891

8

0.398

2

0.794

9

0.355

3

0.708

10

0.316

4

0.631

11

0.282

5

0.562

12

0.251

6

0.501

CLINICAL PHARMACOLOGY

CLINICAL PHARMACOLOGY SECTION

During the initial 24 hours following intravenous injection of technetium Tc 99m medronate, about 50 percent of the dose is retained in the skeleton, and about 50 percent is excreted in the urine. A minimum amount of uptake has been observed in soft-tissue organs, most notably the kidneys.

Clearance of radioactivity from the blood is quite rapid, with about 10 percent of the injected dose remaining at one hour, and less than 5 and 2 percent at two and four hours, respectively. The rapid blood clearance (T ½: 38 to 75 minutes) provides bone to non-osseous tissue ratios favoring early imaging.

Following intravenous administration of technetium Tc 99m medronate, skeletal uptake occurs as a function of blood flow to bone and bone efficiency in extracting the complex. Bone mineral crystals are generally considered to be hydroxyapatite, and the complex appears to have an affinity for the hydroxyapatite crystals in bone.

Deposition of radioactivity in bone is rapid and appears to be related to osteogenic activity as well as the aforementioned skeletal blood perfusion. Skeletal uptake is bilaterally uniform, with larger concentrations in the axial structure and in the long bones. Increased accumulation of radioactivity may be seen, generally, in any bone disease state in which there is increased osteogenesis or a localized increase in osseous blood perfusion; consequently, bone imaging agents generally are not effective in detecting chronic bone diseases.

INDICATIONS AND USAGE

INDICATIONS & USAGE SECTION

Technetium Tc 99m medronate may be used as a bone imaging agent to delineate areas of altered osteogenesis.

CONTRAINDICATIONS

CONTRAINDICATIONS SECTION

None known.

WARNINGS

WARNINGS SECTION

This class of compounds is known to complex cations such as calcium. Particular caution should be used with patients who have or who may be predisposed to hypocalcemia (i.e., alkalosis).

Preliminary reports indicate interference with brain scans using sodium pertechnetate Tc 99m injection which have been preceded by a bone scan using an agent containing stannous ions. This interference may result in false-positive or false-negative brain scans. It is recommended, where feasible, that brain scans precede bone imaging procedures.

The biodistribution of technetium Tc 99m medronate may be altered in the presence of high levels of certain cations (iron, calcium, and aluminum). This may result in reduced uptake of radionuclide in the skeleton and increased extraosseal uptake, which may potentially degrade imaging quality. High levels of these cations may be caused by concomitant medications or medical conditions (e.g., iron overload, hypercalcemia, etc.). Most cases were observed after iron infusion. (See PRECAUTIONS, Drug Interactions.)

PRECAUTIONS

PRECAUTIONS SECTION

General

GENERAL PRECAUTIONS SECTION

The contents of the kit before preparation are not radioactive. However, after the sodium pertechnetate Tc 99m injection is added, adequate shielding of the final preparation must be maintained.

Contents of the reaction vial are intended only for use in the preparation of technetium Tc 99m medronate and are NOT to be administered directly to the patient.

Technetium Tc 99m medronate as well as other radioactive drugs, must be handled with care. Once sodium pertechnetate Tc 99m is added to the vial, appropriate safety measures should be used to minimize external radiation to clinical occupational personnel. Care should also be taken to minimize radiation exposure to patients in a manner consistent with proper patient management.

To minimize the radiation dose to the bladder, the patient should be encouraged to drink fluids and to void immediately before the examination and as often thereafter as possible for the next four to six hours.

Technetium Tc 99m medronate should be formulated within six (6) hours prior to clinical use. Optimal imaging results are obtained one to four hours after administration. Technetium Tc 99m medronate injection should be discarded six hours after reconstitution. The solution should not be used if cloudy.

The components of the kit are sterile and pyrogen-free. It is essential to follow directions carefully and to adhere to strict aseptic procedures during preparation.

The technetium Tc 99m labeling reactions involved in preparing the agent depend on maintaining the stannous ion in the reduced state. Any oxidant present in the sodium pertechnetate Tc 99m supply may, thus, adversely affect the quality of the radiopharmaceutical. Hence, sodium pertechnetate Tc 99m containing oxidants should not be employed.

Radiopharmaceuticals should be used only by physicians who are qualified by training and experience in the safe use and handling of radionuclides.

Drug Interactions

DRUG INTERACTIONS SECTION

The biodistribution of technetium Tc 99m medronate may be altered in the presence of high levels of certain cations (iron, calcium, and aluminum). This may result in reduced uptake of radionuclide in the skeleton and increased extraosseal uptake, which may potentially degrade imaging quality. In patients with high levels of these cations caused by concomitant medications, particularly patients receiving iron infusions, consider performing an imaging study with technetium Tc 99m medronate injection once the cation levels have normalized (e.g., after 3 to 5 half-lives of the cation). (See WARNINGS.)

Carcinogenesis, Mutagenesis, Impairment of Fertility

CARCINOGENESIS & MUTAGENESIS & IMPAIRMENT OF FERTILITY SECTION

No long-term animal studies have been performed to evaluate carcinogenic potential or whether technetium Tc 99m medronate affects fertility in males or females.

Pregnancy

PREGNANCY SECTION

Animal reproduction studies have not been conducted with technetium Tc 99m medronate. It is also not known whether technetium Tc 99m medronate can cause fetal harm when administered to a pregnant woman or can affect reproductive capacity. Technetium Tc 99m medronate should be given to a pregnant woman only if clearly needed.

Nursing Mothers

NURSING MOTHERS SECTION

Technetium Tc 99m is excreted in human milk during lactation; therefore, formula-feedings should be substituted for breast-feedings.

Pediatric Use

PEDIATRIC USE SECTION

Safety and effectiveness in children have not been established.

ADVERSE REACTIONS

ADVERSE REACTIONS SECTION

Several adverse reactions due to technetium Tc 99m medronate have been reported. These were usually hypersensitivity reactions characterized by itching, various skin rashes, hypotension, chills, nausea and vomiting. There have also been rare cases of dizziness and asthenia associated with the use of technetium Tc 99m medronate.

DOSAGE AND ADMINISTRATION

DOSAGE & ADMINISTRATION SECTION

After preparation with oxidant-free sodium pertechnetate Tc 99m injection the suggested dose range of technetium Tc 99m medronate injection in the average patient (70 kg) is 370 MBq to 740 MBq (10 mCi to 20 mCi) given intravenously. Imaging post injection is optimal at 1 to 4 hours.

The patient dose should be measured by a suitable radioactivity calibration system immediately prior to administration.

Parenteral drug products should be inspected visually for particulate matter and discoloration prior to administration whenever solution and container permit. Shielding should be utilized when preparing the technetium Tc 99m medronate injection.

Radiation Dosimetry

SPL UNCLASSIFIED SECTION

The effective half-life was assumed to be the physical half-life for all calculated values. The estimated radiation absorbed doses to an average patient (70 kg) from an intravenous injection of a maximum dose of 740 MBq (20 mCi) of technetium Tc 99m medronate are shown in Table 4.

Table 4

Absorbed Radiation Dose

Organ

mGy/740 MBq

rads/20 mCi

Total Body

1.3

0.13

Bone Total

7.0

0.70

Red Marrow

5.6

0.56

Kidneys

8.0

0.80

Liver

0.6

0.06

Bladder Wall

2-hr. void

26.0

2.60

4.8-hr. void

62.0

6.20

Ovaries

2-hr. void

2.4

0.24

4.8-hr. void

3.4

0.34

Testes

2-hr. void

1.6

0.16

4.8-hr. void

2.2

0.22

Method of Calculation: “S” Absorbed Dose per Unit Cumulated Activity for Selected Radionuclides and Organs, MIRD Pamphlet No. 11, 1975

HOW SUPPLIED

HOW SUPPLIED SECTION

Kit for the Preparation of Technetium Tc 99m Medronate is supplied as kits of 10 reaction vials (NDC 65857-505-10).

Each reaction vial contains a sterile, nonpyrogenic, nonradioactive lyophilized mixture of 20 mg medronic acid, 1 mg ascorbic acid, 0.13 mg (minimum) stannous fluoride, SnF2 and 0.38 mg total tin, maximum (as stannous fluoride, SnF2).

The pH is adjusted with sodium hydroxide or hydrochloric acid prior to lyophilization. The vial does not contain a preservative. The contents of the vial are lyophilized and sealed under nitrogen at the time of manufacture. The pH of the reconstituted product is 5.4 to 6.8.

Kit Contents
10 sterile reaction vials
20 pressure-sensitive labels for technetium Tc 99m medronate
1 package insert

Storage

STORAGE AND HANDLING SECTION

Store the product as supplied at 20° to 25°C (68° to 77°F). After reconstitution store refrigerated at 2° to 8°C (36° to 46°F).

Do not use and discard radiolabeled technetium Tc 99m medronate 6 hours after reconstitution.

DIRECTIONS FOR PREPARATION OF TECHNETIUM Tc 99m MEDRONATE

SPL UNCLASSIFIED SECTION

Procedural Precautions

SPL UNCLASSIFIED SECTION

The lyophilized powder in the reaction vial is sterile and nonpyrogenic and does not contain a preservative. Aseptic procedure and shielded syringes should be used when adding the pertechnetate eluate to the reaction vial and for withdrawal and administration of the dose of the finished medronate agent. Waterproof gloves should be worn to prevent the possibility of radioactive contamination of the hands.

If sodium pertechnetate Tc 99m must be diluted prior to injection into the reaction vial, only preservative-free 0.9% Sodium Chloride Injection USP should be used.

Preparation

SPL UNCLASSIFIED SECTION

Preparation of technetium Tc 99m medronate is done by the following aseptic procedure:

  1. Waterproof gloves should be worn during the preparation procedure.
  2. Place reaction vial in an appropriate lead shield.
  3. Remove the central disc from the reaction vial and swab the rubber closure of the reaction vial with a germicide.
  4. With a sterile syringe, aseptically obtain 0.5 mL to 5 mL [up to 18,500 MBq (500 mCi)] of a suitable, oxidant-free, sterile nonpyrogenic sodium pertechnetate.
  5. Aseptically add the sodium pertechnetate Tc 99m solution to the vial.
  6. Secure the lead shield cover. Swirl the vial for one minute and let stand for one to two minutes.
  7. Record the date and time of preparation on pressure-sensitive label.
  8. Affix pressure-sensitive label to shield.
  9. Examine vial contents. If the solution is not clear and free of particulate matter and discoloration on visual inspection, it should not be used.
  10. Measure the radioactivity using a suitable calibration system and record on the shield label prior to patient administration.
  11. Aseptically withdraw material for use within six (6) hours of preparation. For optimum results, this time should be minimized. The vial contains no bacteriostatic preservative.

 

SPL UNCLASSIFIED SECTION

The U.S. Nuclear Regulatory Commission has approved this reagent kit for distribution to persons licensed to use byproduct material identified in §35.200 of 10 CFR Part 35, to persons who hold an equivalent license issued by an Agreement State, and, outside the United States, to persons authorized by the appropriate authority.

Distributed by:
Cardinal Health 414, LLC
Dublin, OH 43017

Revised February 2025

PRINCIPAL DISPLAY PANEL - Carton Label

PACKAGE LABEL.PRINCIPAL DISPLAY PANEL

Carton Label
Carton Label

DIAGNOSTIC

NDC 65857-505-10

Kit for the Preparation of Technetium Tc 99m Medronate

Rx only • Store the product at 20° to 25°C (68° to 77°F) • For Intravenous Use after radiolabeling with
sodium pertechnetate Tc 99m.
After reconstitution, store refrigerated 2° to 8°C (36° to 46°F) • Use within 6 hours after reconstitution.

Contents:
10 sterile multi-dose reaction vials
20 radioactivity labels
Prescribing information

CardinalHealth™

NONRADIOACTIVE

Kit for the Preparation of Technetium Tc 99m Medronate

For preparation of technetium Tc 99m medronate for bone imaging
Each reaction vial contains a sterile, nonpyrogenic nonradioactive lyophilized
mixture of 20 mg medronic acid, 1 mg ascorbic acid, and 0.13 mg (minimum)
stannous fluoride SnF2 and 0.38 mg total tin, maximum (as stannous fluoride,
SnF2); pH adjusted with sodium hydroxide or hydrochloric acid prior to
lyophilization.

Distributed by
Cardinal Health 414, LLC
Dublin, OH 43017

Contains no preservative. Vial contents are
sealed under nitrogen at time of manufacture.
Recommended Dose: See Prescribing
Information.

DailyMed Pharmacologic Classes#

Class, Version, Type table
ClassVersionTypeEffective
TECHNETIUM TC-99M MEDRONATE Pharmacologic Class Indexing2Indexing - Pharmacologic Class20180813

DailyMed Product Concepts#

Product concept, Relation, Version table
Product conceptRelationVersionEffective
c5cd4727-ac49-4409-82b1-5bd8006c3ec7Product name120171122

DailyMed Package Descriptions#

Package NDC, Product, Description table
Package NDCProductDescriptionFormQuantityStrengthSPL version
65857-505-10Kit for the Preparation of Technetium Tc 99m Medronate10 in 1 CARTONINJECTION, POWDER, LYOPHILIZED,105

DailyMed Billing Units#

Package NDC, Billing unit, Product NDC table
Package NDCBilling unitProduct NDCDailyMed indexing SPLSPL versionEffective
65857-505-10EA - Each65857-505ddd0c35a-8726-443e-819f-0bcefb99b49412023-01-09

Products#

Every source-derived product name is available through these pages.

DailyMed product names page 1 of 1 · 8 matching rows.

NDC Codes#

Product NDC, Package NDC table
Product NDCPackage NDC
65857-50565857-505-10

Ingredients#

Every source-derived ingredient row is available through these pages.

DailyMed ingredient rows page 1 of 1 · 5 matching rows.

Source Document#

Source XML

Orange Book application contexts#

All distinct exact application/product contexts derived from this label’s complete NDC list are paginated below.

Orange Book application contexts page 1 of 1 · 1 matching rows.

Source provenance: Browse the complete Orange Book source catalog · source snapshot 45.

Orange Book products#

Current product rows page 1 of 1 · 1 matching rows.

Application-product, Trade name, Ingredient table
Application-productTrade nameIngredientStrengthDosage form / routeTE codesRLD / RSApproval date
N018107-001TECHNETIUM TC-99M MEDRONATE KITTECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 1982

Therapeutic equivalence codes#

Current TE-code rows page 1 of 1 · 1 matching rows.

Application-product, TE code table
Application-productTE code
N018107-001AP

Observed Orange Book product history#

Observed FDA ZIP history: Each table is queried independently by exact application/product key from successfully parsed Orange Book snapshots. Capture times identify archived source observations; absence or a change between snapshots is not inferred. FDA publication files that were not recoverable as structured ZIP data are not represented as states.

Product history page 1 of 2 · 45 observed states.

Captured, Edition, Application-product table
CapturedEditionApplication-productTrade nameStrengthDosage form / routeProduct TE source textRLD / RSApproval dateSource SHA-256
2026-11-14 07:37:172026-10N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 1982d4dbc9d85df4…
2026-10-15 13:18:302026-09N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 1982c2088c7a36db…
2026-09-14 22:38:342026-08N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 198284e616aacf4f…
2026-08-18 06:07:402026-07N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 1982caaa826d4ba7…
2026-02-19 14:30 UTC2026-02N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 1982011fe1cb6892…
2025-12-14 10:44 UTC · 2 captures of this ZIP2025-12N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 198231067a03dcf5…
2025-08-23 18:47 UTC2025-08N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 19826a471c1ec25d…
2025-03-22 03:13 UTC · 3 captures of this ZIP2025-03N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 1982fd3edfee7708…
2025-02-26 10:13 UTC · 3 captures of this ZIP2025-02N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 1982b8a1b40f171c…
2025-01-19 17:59 UTC · 7 captures of this ZIP2025-01N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 198203ed91905a0d…
2024-12-13 21:23 UTC · 2 captures of this ZIP2024-12N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 19822680178bc6a6…
2024-09-14 05:58 UTC · 2 captures of this ZIP2024-09N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 19825bbf6a4d5a75…
2024-11-08 22:44 UTC · 3 captures of this ZIP2024-11N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 1982d8e5a09893c0…
2024-10-29 15:01 UTC2024-10N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 1982d06236e962d9…
2024-08-13 05:28 UTC · 3 captures of this ZIP2024-08N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 198279d66fd596c7…
2024-07-13 05:37 UTC · 2 captures of this ZIP2024-07N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 1982301d65b070ca…
2024-06-18 03:08 UTC · 5 captures of this ZIP2024-06N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 19821e350fbaab3a…
2024-05-31 18:47 UTC2024-05N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 19828072bd15b7f6…
2022-06-29 02:47 UTC · 2 captures of this ZIP2022-06N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 19825c6f7cd8ea54…
2022-04-08 23:34 UTC2022-04N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 19825d02ea3f76ae…
2022-04-04 05:41 UTC2022-04N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 19824b0b4de00fa7…
2019-12-13 00:20 UTC2019-12N018107-001MDP-BRACCON/AINJECTABLE / INJECTIONApproved before 198274a2ff9319b5…
2022-03-09 01:35 UTC2022-03N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 1982bb7c543d1eb4…
2021-12-28 21:50 UTC2021-12N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 1982782e0a99824c…
2021-05-05 16:15 UTC · 3 captures of this ZIP2021-05N018107-001MDP-BRACCON/AINJECTABLE / INJECTIONApproved before 198287673890dc5c…
2021-03-12 10:30 UTC2021-03N018107-001MDP-BRACCON/AINJECTABLE / INJECTIONApproved before 19825aa47cf7b7d7…
2020-12-22 03:56 UTC2020-12N018107-001MDP-BRACCON/AINJECTABLE / INJECTIONApproved before 19828869cabd3fbd…
2020-11-12 02:37 UTC2020-11N018107-001MDP-BRACCON/AINJECTABLE / INJECTIONApproved before 1982c0c555d07b60…
2019-12-14 00:12 UTC2019-12N018107-001MDP-BRACCON/AINJECTABLE / INJECTIONApproved before 19823f01610625f2…
2019-09-15 20:21 UTC2019-09N018107-001MDP-BRACCON/AINJECTABLE / INJECTIONApproved before 1982b00525d2431f…
2019-07-19 19:46 UTC2019-07N018107-001MDP-BRACCON/AINJECTABLE / INJECTIONApproved before 1982ea99ee380514…
2024-03-16 18:09 UTC · 4 captures of this ZIP2024-03N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 19826a51e52b5d6a…
2024-02-18 07:12 UTC2024-02N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 19821c564ffb4f44…
2023-12-20 04:57 UTC2023-12N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 1982ea1830bbd6c7…
2023-11-28 05:40 UTC · 2 captures of this ZIP2023-11N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 1982a72a2bbeb626…
2023-10-25 00:34 UTC · 2 captures of this ZIP2023-10N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 19829b2671bbb829…
2023-07-15 15:27 UTC · 2 captures of this ZIP2023-07N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 1982a67488948f0b…
2023-06-13 01:57 UTC · 3 captures of this ZIP2023-06N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 19823f0d92c62455…
2023-05-13 08:27 UTC2023-05N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 1982053a50430f4f…
2023-01-26 05:58 UTC2023-01N018107-001TECHNETIUM TC-99M MEDRONATE KITN/AINJECTABLE / INJECTIONAPApproved before 19823bdfa0b2c4d7…

Observed Orange Book normalized TE history#

Captured, Edition, Application-product table
CapturedEditionApplication-productTE codeOrderSource SHA-256
2026-11-14 07:37:172026-10N018107-001AP1d4dbc9d85df4…
2026-10-15 13:18:302026-09N018107-001AP1c2088c7a36db…
2026-09-14 22:38:342026-08N018107-001AP184e616aacf4f…
2026-08-18 06:07:402026-07N018107-001AP1caaa826d4ba7…
2026-02-19 14:30 UTC2026-02N018107-001AP1011fe1cb6892…
2025-12-14 10:44 UTC · 2 captures of this ZIP2025-12N018107-001AP131067a03dcf5…
2025-08-23 18:47 UTC2025-08N018107-001AP16a471c1ec25d…
2025-03-22 03:13 UTC · 3 captures of this ZIP2025-03N018107-001AP1fd3edfee7708…
2025-02-26 10:13 UTC · 3 captures of this ZIP2025-02N018107-001AP1b8a1b40f171c…
2025-01-19 17:59 UTC · 7 captures of this ZIP2025-01N018107-001AP103ed91905a0d…
2024-12-13 21:23 UTC · 2 captures of this ZIP2024-12N018107-001AP12680178bc6a6…
2024-09-14 05:58 UTC · 2 captures of this ZIP2024-09N018107-001AP15bbf6a4d5a75…
2024-11-08 22:44 UTC · 3 captures of this ZIP2024-11N018107-001AP1d8e5a09893c0…
2024-10-29 15:01 UTC2024-10N018107-001AP1d06236e962d9…
2024-08-13 05:28 UTC · 3 captures of this ZIP2024-08N018107-001AP179d66fd596c7…
2024-07-13 05:37 UTC · 2 captures of this ZIP2024-07N018107-001AP1301d65b070ca…
2024-06-18 03:08 UTC · 5 captures of this ZIP2024-06N018107-001AP11e350fbaab3a…
2024-05-31 18:47 UTC2024-05N018107-001AP18072bd15b7f6…
2022-06-29 02:47 UTC · 2 captures of this ZIP2022-06N018107-001AP15c6f7cd8ea54…
2022-04-08 23:34 UTC2022-04N018107-001AP15d02ea3f76ae…
2022-04-04 05:41 UTC2022-04N018107-001AP14b0b4de00fa7…
2022-03-09 01:35 UTC2022-03N018107-001AP1bb7c543d1eb4…
2021-12-28 21:50 UTC2021-12N018107-001AP1782e0a99824c…
2024-03-16 18:09 UTC · 4 captures of this ZIP2024-03N018107-001AP16a51e52b5d6a…
2024-02-18 07:12 UTC2024-02N018107-001AP11c564ffb4f44…
2023-12-20 04:57 UTC2023-12N018107-001AP1ea1830bbd6c7…
2023-11-28 05:40 UTC · 2 captures of this ZIP2023-11N018107-001AP1a72a2bbeb626…
2023-10-25 00:34 UTC · 2 captures of this ZIP2023-10N018107-001AP19b2671bbb829…
2023-07-15 15:27 UTC · 2 captures of this ZIP2023-07N018107-001AP1a67488948f0b…
2023-06-13 01:57 UTC · 3 captures of this ZIP2023-06N018107-001AP13f0d92c62455…
2023-05-13 08:27 UTC2023-05N018107-001AP1053a50430f4f…
2023-01-26 05:58 UTC2023-01N018107-001AP13bdfa0b2c4d7…
2022-11-12 20:34 UTC · 5 captures of this ZIP2022-11N018107-001AP13a93d1ddd44b…
2022-10-28 04:53 UTC2022-10N018107-001AP1f41ea6bd6efb…
2022-09-29 23:25 UTC2022-09N018107-001AP1e64feba35796…
2022-07-09 03:26 UTC · 3 captures of this ZIP2022-07N018107-001AP1cb3db0bc1861…
2026-07-26 02:55 UTC · 3 captures of this ZIP2026-06N018107-001AP1a50c72e98297…

openFDA label cross-check#

OpenFDA label data provides additional search and identifier links. DailyMed’s Structured Product Label is the canonical label on FDA.report. Matching records are deduplicated before they are shown below.

Matched openFDA labels page 1 of 1 · 1 matching rows.

Brand, Generic, Manufacturer table
BrandGenericManufacturerSPL set IDEffective dateAvailable safety fieldsJoin
Kit for the Preparation of Technetium Tc 99m MedronateTECHNETIUM TC 99M MEDRONATECardinal Health 414, LLC54608807-4df6-49ba-b065-59a19ef224c42025-09-08Warnings, Adverse reactionsExact identifier
ndc (package): 65857-505-10
ndc (product): 65857-505
ndc11 (package): 65857050510
spl id: d54cd404-317c-4a70-a22d-1667550ab5bc
spl set id: 54608807-4df6-49ba-b065-59a19ef224c4

Reported adverse events (FAERS/openFDA)#

Adverse event summaries are temporarily unavailable. Other product information remains available.