General: Betamethasone dipropionate gel
(augmented) should not be used in the treatment of rosacea or perioral
dermatitis, and it should not be used on the face, groin, or in the axillae.
Systemic absorption of topical corticosteroids can produce reversible
hypothalamic-pituitary-adrenal (HPA) axis suppression with the potential for
gluco-corticosteroid insufficiency after withdrawal of treatment. Manifestations
of Cushing's syndrome, hyperglycemia, and glucosuria can also be produced in
some patients by systemic absorption of topical corticosteroids while on
treatment.
At 7 g per day (applied once daily or as 3.5 g twice daily), betamethasone
dipropionate gel (augmented) was shown to cause inhibition of the HPA axis
following application for one, two or three weeks to diseased skin in some
patients with psoriasis or atopic dermatitis. These effects were reversible upon
discontinuation of treatment.
Patients receiving betamethasone dipropionate gel (augmented) applied to
large areas should be evaluated periodi- cally for evidence of HPA axis
suppression. This may be done by using the ACTH-stimulation, morning plasma
cortisol and urinary free-cortisol tests. Patients should not be treated with
betamethasone dipropionate gel (augmented) for more than 2 weeks at a time, and
amounts greater than 50 g per week should not be used because of the potential
for the drug to suppress the HPA axis.
If HPA axis suppression is noted, an attempt should be made to withdraw the
drug, to reduce the frequency of application, or to substitute a less potent
corticosteroid. Recovery of HPA axis function is generally prompt and complete
upon discontinuation of topical corticosteroids. Infrequently, signs and
symptoms of glucocorticosteroid insufficiency may occur, requiring supplemental
systemic corticosteroids. For information on systemic supplementation, see
prescribing information for systemic corticosteroids.
Pediatric patients may be more susceptible to systemic toxicity from
equivalent doses due to their larger skin surface to body mass ratios (see PRECAUTIONS-Pediatric Use).
If irritation develops, betamethasone dipropionate gel (augmented) should be
discontinued and appropriate therapy instituted. Allergic contact dermatitis
with corticosteroids is usually diagnosed by observing failure to heal rather
than noting clinical exacerbation as with most topical products not containing
corticosteroids. Such an observation should be corroborated with appropriate
diagnostic patch testing.
If concomitant fungal and/or bacterial skin infections are present or
develop, an appropriate antifungal or antibacterial agent should be used. If a
favorable response does not occur promptly, use of betamethasone dipropionate
gel (augmented) should be discontinued until the infection has been adequately
controlled.
Information for Patients: Patients using
topical corticosteroids should receive the following information and
instructions:
- The medication is to be used as directed by the physician. It is for
external use only. Avoid contact with the eyes.
- The medication should not be used for any disorder other than that for which
it was prescribed.
- The treated skin area should not be bandaged or otherwise covered or wrapped
so as to be occlusive.
- Patients should report to their physician any signs of local adverse
reactions.
Laboratory Tests: The following tests may
be helpful in evaluating patients for HPA axis suppression: ACTH-stimu-lation
test, Morning plasma-cortisol test, Urinary free-cortisol test.
Carcinogenesis, Mutagenesis, Impairment of
Fertility: Long-term animal studies have not been performed to evaluate
the carcinogenic potential of betamethasone dipropionate.
Studies in rabbits, mice and rats using intramuscular doses up to 1, 33 and 2
mg/kg, respectively, resulted in dose related increases in fetal resorptions in
the rabbits and mice.
Pregnancy:Teratogenic Effects: Pregnancy
Category C: Corticosteroids have been shown to be teratogenic in
laboratory animals when administered systemically at relatively low dosage
levels. Some corticosteroids have been shown to be teratogenic after dermal
application to laboratory animals.
Betamethasone dipropionate has been shown to be teratogenic in rabbits when
given by the intramuscular route at doses of 0.05 mg/kg. This dose is
approximately 26 times the human topical dose of betamethasone dipropionate gel
(augmented) assuming human percutaneous absorption of approximately 3% and the
use in a 70 kg person of 7 g per day. The abnormalities observed included
umbilical hernias, cephalocele and cleft palate.
There are no adequate and well-controlled studies of the teratogenic
potential of betamethasone dipropionate in pregnant women. Therefore,
betamethasone dipropionate gel (augmented) should be used during pregnancy only
if the potential benefit justifies the potential risk to the fetus.
Nursing Mothers: Systemically
administered corticosteroids appear in human milk and could suppress growth,
interfere with endogenous corticosteroid production, or cause other untoward
effects. It is not known whether topical administration of corticosteroids could
result in sufficient systemic absorption to produce detectable quantities in
human milk. Because many drugs are excreted in human milk, caution should be
exercised when betamethasone dipropionate gel (augmented) is administered to a
nursing woman.
Pediatric Use: Data regarding use of
Betamethasone Dipropionate Gel (augmented) in pediatric patients are not
available, so use of this product in patients under the age of 12 is not
recommended. Because of a higher ratio of skin surface area
to body mass, pediatric patients are at a greater risk than adults of HPA axis
suppression when they are treated with topical corticosteroids. They are,
therefore, also at greater risk of glucocorticosteroid insufficiency after
withdrawal of treatment and of Cushing's syndrome while on treatment.
Adverse effects, including striae, have been reported with inappropriate use of
topical corticosteroids in infants and pediatric patients.
HPA axis suppression, Cushing's syndrome, and intracranial hypertension have
been reported in pediatric patients receiving topical corticosteroids.
Manifestations of adrenal suppression in pediatric patients include linear
growth retardation, delayed weight gain, low plasma cortisol levels, and absence
of response to ACTH stimulation. Manifestations of intracranial hypertension
include bulging fontanelles, headaches, and bilateral papilledema.
Geriatric Use: Clinical studies of
Betamethasone Dipropionate Gel (Augmented) included 65 subjects who were 65
years of age and over and 15 subjects who were 75 years of age and over. No
overall differences in safety or effectiveness were observed between these
subjects and younger subjects, and other reported clinical experience has not
identified differences in responses between the elderly and younger patients.
However, greater sensitivity of some older individuals cannot be ruled out.