Oxygen

Manufacturer
WELSCO, INC.
Effective date
2025-10-31
Label type
HUMAN PRESCRIPTION DRUG LABEL
Version
27
Source
monthly-update
Hydrated at
2026-06-03 17:42:19

Label at a glance#

ProductOxygen
Active ingredientOXYGEN
Label structure3 sections

Label contents#

Full prescribing information#

PACKAGE LABEL.PRINCIPAL DISPLAY PANEL

nexAir

OXYGEN, COMPRESSED USP

UN1072

CAS: 7782-44-7

Produced by Air Liquefaction

Oxygen (O2) 100% under 2000 psi pressure (59 F or 15 C)

CONTENTS:

Cylinder type: Liters NDC

E 680 12213-720-68

D 413 12213-720-17

Service and transfill: No user-serviceable parts. Return to distributor for service/repair. Return to Linde to be refilled.

NO SMOKING NO VAPING

MR CONDITIONAL

Static Field Strength 3.0T

Static Field Gradient 375 Gauss/cm

LIV Linde Integrated Valve Portable Oxygen system.

INDICATIONS FOR USE: The LIV is an integrated portable oxygen delivery system intented to provide supplemental oxygen to pediatrics and adults. The device is MR-conditional (per ASTM Standard 2503-05), and intended for use during MR imaging or MRI systems up to 3.0T.

DANGER: MAY CAUSE OR INTENSIFY FIRE; OXIDIZER. CONTAINS GAS UNDER PRESURE; MAY EXPLODE IF HEATED.

Do not handle until all safety precautions have been read and understood. Keep and store away from clothing and other combustible materials. Keep valves and fittings free from grease and oil. Use and store only outdoors or in a well-ventilated place. In case of fire: Stop leak if safe to do so. Use a back flow preventive device in the piping. Use only with equipment of compatible materials of construction and rated for cylinder pressure. Use only with equipment cleaned for oxygen service. Open valve slowly. Close valve after each use and when empty. Protect form sunlight when ambient temperature exceeds 52 C (125 F). Read and follow the Safety Data Sheet (SDS) before use.

WARNING: Keep out of reach of children. Uninterrupted use of high concentrations of oxygen over a long duration, without monitoring its effect on oxygen content and arterial blood, may be harmful. Do not attempt to use on patients who have stopped breathing unless used in conjunction with resuscitative equipment. For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications, Rx required.

Federal law requires that this container be refilled with oxygen USP only by establishments registered as a drug manufacturer in accordance with the Federal Food, Drug, and Cosmetic Act.

Note: Keep valve minimum 12 inches (30 cm) away from magnet opening. Do not move the package during MRI scan, as the MR data quality may be degraded.

DO NOT REMOVE THIS LABEL

MR CONDITIONAL

Static Field Strength 3.0T

Static Field Gradient 375 Gauss/cm

Instructions for use

Operating temperature -4 F to 113 F (-20 C to +45 C).

Only use with devices intended for the product administration.

Prepare to change the cylinder when the pointer on the gauge enters the red area.

To ensure the correct prescribed flow rate, always make sure that the flow selector is positioned on a numbered flow setting, not between the flow settings.

1) Pressure outlet (if provided) 5) Flow Selector

2) Shut-off valve 4) Flow outlet

3) Gauge

Before use:

Check gauge (3) for content.

Check flow selector (5) is set at zero.

Connect equipment to outlet (1 or 4).

Slowly open shut off valve (2) fully by turning counterclockwise.

If equipment is connected to the flow outlet (4) select flow by turning flow selector (5) stepwise up through flow settings.

The patient can now be connected to a delivery device

After use:

Turn flow selector (5) to zero by turning the flow selector stepwise down through flow settings.

Close shut off valve (2) by turning clockwise.

Vent downstream equipment.

Disconnect the equipment from outlet (1 or 4).

Distributed by:

nexAir, LLC

1350 Concourse Ave., Suite 103

Memphis, TN 38104

888-639-2475 www.nexAir.com oxygen liv 2025oxygen liv 2025

PACKAGE LABEL.PRINCIPAL DISPLAY PANEL

UN1072

OXYGEN, COMPRESSED USP

DO NOT REMOVE THIS LABEL.

DANGER! MAY CAUSE OR INTENSIFY FIRE; OXIDIZER. CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED.

Do not handle until all safety precautions have been read and understood. Keep and store away from clothing and other combustible materials. Keep valves and fittings free from grease and oil. Use and store only outdoors or in a well-ventilated place. In case of fire: Stop leak if safe to do so. Use a back flow preventive device in the piping. Use only with equipment of compatible materials of construction and rated for cylinder pressure. Use only with equipment cleaned for oxygen service. Do not open valves until connected to equipment prepared for use. Open valve slowly. Close valve after each use and when empty. Protect from sunlight when ambient temperature exceeds 52 C (125 F). Read and follow the Safety Data Sheet (SDS) before use. WARNING: Keep out of reach of children. Uninterrupted use of high concentrations of oxygen over a long duration, without monitoring its effect on oxygen content of arterial blood, may be harmful. Do not attempt to use on patients who have stopped breathing unless used in conjunction with resuscitative equipment. For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications, RX required. Federal law requires that this container be refilled with oxygen USP only by establishments registered as a drug manufacturer in accordance with the Federal Food, Drug and Cosmetic Act.

PRODUCED BY AIR LIQUFACTION CAS: 7782-44-7

IN CASE OF EMERGENCY: CALL 1-888-639-2474

NO SMOKING

NO VAPING

nexAir

Distributed by nexAir, LLC, 1350 Concourse Ave., Suite 103, Memphis, TN 38104 oxygen one 2025oxygen one 2025

PACKAGE LABEL.PRINCIPAL DISPLAY PANEL

UN1073

OXYGEN, REFRIGERATED LIQUID USP

ALWAYS KEEP CONTAINER IN UPRIGHT POSITION

DO NOT CHANGE OR FORCE-FIT CONNECTIONS

DANGER!

MAY CAUSE OR INTENSIFY FIRE; OXIDIZER. CONTAINS REFRGIERATED GAS; MAY CAUSE CRYOGENIC BURNS OR INJURY. COMBUSTIBLES IN CONTACT WITH OXIDIZING REFRIGERATED LIQUIDS MAY EXPLODE ON IGNITION OR IMPACT.

NO SMOKING

NO VAPING

IN CASE OF EMERGENCY: CALL 1-88-639-2474

CAS: 7782-44-7

DO NOT REMOVE THIS LABEL.

Do not handle until all safety precautions have been read and understood. Keep/Store away from combustible materials, clothing. Keep reduction valves/valves and fittings free from oil and grease. Use and store only outdoors or in a well-ventilated place. Wear cold insulating gloves/face shield/eye protection. IN CASE OF FIRE: Stop leak if safe to do so. Use a back flow preventive device in the piping. Use only with equipment of compatible materials of construction and rated for cylinder pressure. Use only with equipment cleaned for oxygen service. Do NOT change or force fit connections. Do not open valve until connected to equipment prepared for use. Open valve slowly. Close valve after each use and when empty. Always keep container in upright position. Avoid spills. Do not walk on or roll equipment over spills. Read and follow the Safety Data Sheet (SDS) before use.

FIRST AID: IF ON SKIN: Thaw frosted parts with lukewarm water. Do not rub affected area. Get immediate medical advice/attention.

WARNING: Keep out of reach of children. Uninterrupted use of high concentrations of oxygen over a long duration, without monitoring its effects on oxygen content of arterial blood, may be harmful. Do not attempt to use on patients who have stopped breathing unless used in conjunction with resuscitative equipment. For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications, RX required. Federal law requires that this container be refilled with oxygen USP only by establishments registered as a drug manufacturer in accordance with the Federal Food, Drug and Cosmetic Act.

PRODUCED BY AIR LIQUEFACITON

nexAir

Distributed by nexAir, LLC, 1350 Concourse Ave., Suite 103, Memphis, TN 38104 oxygen refrig 2025oxygen refrig 2025

DailyMed Socrata Ingredients#

Ingredient, Type, UNII table
IngredientTypeUNIISPL versionUploaded
OxygenACTIVE INGREDIENTS88TT1406511
OxygenACTIVE MOIETYS88TT1406511

Products#

Every source-derived product name is available through these pages.

DailyMed product names page 1 of 1 · 1 matching rows.

NDC Codes#

Ingredients#

Every source-derived ingredient row is available through these pages.

DailyMed ingredient rows page 1 of 1 · 1 matching rows.

Name, UNII, Kind table
NameUNIIKind
OXYGENS88TT14065ACTIB

Source Document#

Source XML · Source PDF

Older Hydrated Versions#

Version, Effective date, Source table
VersionEffective dateSourceHydrated
262024-12-02full-release2026-05-31 21:18:35

Orange Book application contexts#

All distinct exact application/product contexts derived from this label’s complete NDC list are paginated below.

Orange Book application contexts page 1 of 1 · 1 matching rows.

Source provenance: Browse the complete Orange Book source catalog.

openFDA label cross-check#

OpenFDA label data provides additional search and identifier links. DailyMed’s Structured Product Label is the canonical label on FDA.report. Matching records are deduplicated before they are shown below.

Matched openFDA labels page 1 of 1 · 1 matching rows.

Brand, Generic, Manufacturer table
BrandGenericManufacturerSPL set IDEffective dateAvailable safety fieldsJoin
521bffb5-75f0-fb56-e063-6294a90acfb090b565a0-00bd-4186-b320-47e59e489e072026-05-18Exact identifier
spl set id: 90b565a0-00bd-4186-b320-47e59e489e07

Reported adverse events (FAERS/openFDA)#

Adverse event summaries are temporarily unavailable. Other product information remains available.