Nitrous Oxide
- Manufacturer
- Encompass Medical & Specialty Gases, Ltd.
- Effective date
- 2010-12-03
- Label type
- HUMAN PRESCRIPTION DRUG LABEL
- Version
- 1
- Source
- full-release
- Hydrated at
- 2026-05-31 20:10:52
Label at a glance#
Contacts and useful links#
Label contents#
Full prescribing information#
PACKAGE LABEL.PRINCIPAL DISPLAY PANEL
LifeGas
NITROUS OXIDE UN1070
USP CAS: 10024-97-2
Distributed by: Linde Linde Gas North America LLC 575 Mountain Ave. Murray Hill, NJ 07974
NON-FLAMMABLE GAS 2 OXIDIZER 5.1
MEDICAL GAS
Rx only. WARNING: Administration of Nitrous Oxide may be hazardous or contraindicated. For use only by or under the supervision of a licensed practitioner who is experienced in the use and administration of Nitrous Oxide and is familiar with the indications, effects, dosages, methods, and frequency and duration of administration, and with the hazards, contraindications and side effects and the precautions to be taken. When used as a diluent for oxygen to produce respirable mixtures, user must assure sufficient oxygen concentration to sustain life.
WARNING: HIGH PRESSURE OXIDIZING LIQUID AND GAS. CAN CAUSE RAPID SUFFOCATION. MAY CAUSE ANESTHETIC EFFECTS. MAY CAUSE FROSTBITE. For liquid withdrawal, wear protective equipment to prevent getting liquid in eyes, on skin or clothing. Keep away from heat, flame or sparks. Keep oil, grease and other combustibles away. Transport, store and use with adequate ventilation. Do not strike arc or laser beam on cylinder. Use equipment cleaned for Oxygen service and rated for cylinder pressure. . Use a back flow preventive device in the piping. Cylinder temperature should not exceed 52C (125F). Always secure cylinder in upright position. Use in accordance with the Material Safety Data Sheets for this product, available at Web Site:
www.lindeus.com. Close valve after each use and when empty. Return cylinder with 25 psig pressure and cylinder cap secured, if applicable. Open valve slowly.
FIRST AID: IN CASE OF FROSTBITE, obtain medical treatment immediately.
IF INHALED, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Call a physician.
DO NOT REMOVE THIS LABEL.
LG040C (R 02/08) L and SP 7468
PACKAGE LABEL.PRINCIPAL DISPLAY PANEL
NITROUS OXIDE USP UN1070
NON-FLAMMABLE GAS 2 OXIDIZER 5.1 37736 (06/05)
Rx only. WARNING: Administration of Nitrous Oxide may be hazardous or contraindicated. For use only by or under the supervision of a licensed practitioner who is experienced in the use and administration of Nitrous Oxide and is familiar with the indications, effects, dosages, methods, and frequency and duration of administration, and with the hazards, contraindications and side effects and the precautions to be taken.
WARNING: HIGH PRESSURE OXIDIZING LIQUID AND GAS. VIGOROUSLY ACCELERATES COMBUSTION. CAN CAUSE RAPID SUFFOCATION. CAN CAUSE ANESTHETIC EFFECTS. MAY CAUSE FROSTBITE. Avoid breathing gas. Store and use with adequate ventilation. Keep oil and grease away. Use only with equipment cleaned for oxygen and rated for cylinder pressure. Do not get liquid in eyes, on skin, or clothing. Cylinder temperature should not exceed 52C (125F). Open valve slowly. Close valve after each use and when empty. Use a back flow preventive device in the piping. Use in accordance with the Material Safety Data Sheets (MSDS).
FIRST AID: IF INHALED, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Call a physician. IN CASE OF FROSTBITE, obtain medical treatment immediately.
CAS: 10024-97-2
DO NOT REMOVE THIS PRODUCT LABEL.
Cylinders must be refilled by:
Encompass Medical and Specialty Gases, LTD. 4646 Linden Road P.O. Box 5404 Rockford, IL 61109
CONTENTS: LTRS. CU. FT.
FDA-Initiated Inactive NDC Indexing#
DailyMed Package Descriptions#
| Package NDC | Product | Description | Form | Quantity | Strength | SPL version |
|---|---|---|---|---|---|---|
| 48883-004-01 | Nitrous Oxide | 148 L in 1 CYLINDER | GAS | 148 | 1 | |
| 48883-004-02 | Nitrous Oxide | 936 L in 1 CYLINDER | GAS | 936 | 1 | |
| 48883-004-03 | Nitrous Oxide | 991 L in 1 CYLINDER | GAS | 991 | 1 | |
| 48883-004-04 | Nitrous Oxide | 1577 L in 1 CYLINDER | GAS | 1577 | 1 | |
| 48883-004-05 | Nitrous Oxide | 1726 L in 1 CYLINDER | GAS | 1726 | 1 | |
| 48883-004-06 | Nitrous Oxide | 2464 L in 1 CYLINDER | GAS | 2464 | 1 | |
| 48883-004-07 | Nitrous Oxide | 4927 L in 1 CYLINDER | GAS | 4927 | 1 | |
| 48883-004-08 | Nitrous Oxide | 7386 L in 1 CYLINDER | GAS | 7386 | 1 | |
| 48883-004-09 | Nitrous Oxide | 7391 L in 1 CYLINDER | GAS | 7391 | 1 | |
| 48883-004-10 | Nitrous Oxide | 12318 L in 1 DEWAR | GAS | 12318 | 1 | |
| 48883-004-11 | Nitrous Oxide | 13810 L in 1 DEWAR | GAS | 13810 | 1 |
DailyMed Dashboard NDC Coverage#
DailyMed Socrata Ingredients#
| Ingredient | Type | UNII | SPL version | Uploaded |
|---|---|---|---|---|
| Nitrous Oxide | ACTIVE INGREDIENT | K50XQU1029 | 1 | |
| Nitrous Oxide | ACTIVE MOIETY | K50XQU1029 | 1 |
Products#
Every source-derived product name is available through these pages.
- Nitrous Oxide
NDC Codes#
| Product NDC | Package NDC |
|---|---|
| 48883-004 | 48883-004-01, 48883-004-02, 48883-004-03, 48883-004-04, 48883-004-05, 48883-004-06, 48883-004-07, 48883-004-08, 48883-004-09, 48883-004-10, 48883-004-11 |
Ingredients#
Every source-derived ingredient row is available through these pages.
| Name | UNII | Kind |
|---|---|---|
| Nitrous Oxide | K50XQU1029 | ACTIB |
Source Document#
openFDA label cross-check#
OpenFDA label data provides additional search and identifier links. DailyMed’s Structured Product Label is the canonical label on FDA.report. Matching records are deduplicated before they are shown below.
| Brand | Generic | Manufacturer | SPL set ID | Effective date | Available safety fields | Join |
|---|---|---|---|---|---|---|
| ef3b5bcc-51d6-4ec8-8f5d-d5b8ff7fbba5 | ffcfc7c1-5806-4f37-9a0f-f64cb06410e0 | 2010-12-03 | ef3b5bcc-51d6-4ec8-8f5d-d5b8ff7fbba5 ffcfc7c1-5806-4f37-9a0f-f64cb06410e0 |
Reported adverse events (FAERS/openFDA)#