General: Systemic absorption of topical corticosteroids has produced reversible
hypothalamic-pituitary-adrenal (HPA) axis suppression, manifestations of Cushing’s
syndrome, hyperglycemia, and glucosuria in some patients. Conditions which augment
systemic absorption include the application of the more potent steroids, use over large
surface areas, prolonged use, and the addition of occlusive dressings.
Therefore, patients receiving a large dose of a potent topical steroid applied to a
large surface area and under an occlusive dressing should be evaluated periodically
for evidence of HPA axis suppression by using the urinary free cortisol and ACTH
stimulation tests. If HPA axis suppression is noted, an attempt should be made to
withdraw the drug, to reduce the frequency of application, or to substitute a less
potent steroid. Recovery of HPA axis function is generally prompt and complete upon
discontinuation of the drug. Infrequently, signs and symptoms of steroid withdrawal
may occur, requiring supplemental systemic corticosteroids. Children may absorb
proportionally larger amounts of topical corticosteroids and thus be more susceptible
to systemic toxicity. (See Precautions-Pediatric Use.) If irritation develops, topical
corticosteroids should be discontinued and appropriate therapy instituted.
In the presence of dermatological infections, the use of an appropriate antifungal
or antibacterial agent should be instituted. If a favorable response does not occur
promptly the corticosteroid should be discontinued until the infection has been
adequately controlled.
Information for the Patient: Patients using topical corticosteroids should receive the following information and instructions:
1. This medications is to be used as directed by the physician. It is for external use only. Avoid contact with the eyes.
2. Patients should be advised not to use this medication for any disorder other than for which it was prescribed.
3. The treated skin area should not be bandaged or otherwise covered or wrapped as to be occlusive unless directed by the physician.
4. Patient should report any signs of local adverse reactions especially under occlusive dressings.
5. Parents of pediatric patients should be advised not to use tight-fitting diapers or plastic pants on a child being treated in the diaper area, as these garment may constitute occlusive dressings.
Laboratory Tests: The following tests may be helpful in evaluating the HPA axis suppression: Urinary free cortisol test. ACTH stimulation test
Carcinogenesis, mutagenesis, and Impairment of Fertility: Long-term animal studies have not been performed to evaluate the carcinogenic potential or the effect on fertility of topical corticosteroids. Studies to determine mutagenecity with prednisolone and hydrocortisone have revealed negative results.
Pregnancy: Teratogenic Effects: Pregnancy Category C: Corticosteroids are generally teratogenic in laboratory animals when administered systemically at relatively low dosage levels. The more potent coricosteroids have been shown to be teratogenic after dermal application in laboratory animals. There are no adequate and well-controlled studeis in pregnant women on teratogenic effects from topically applied corticosteroids. Therefore, topical corticosteroids should be used during pregnancy only if the potential benefit justifies the potential risk to the fetus. Drugs of this class should not be used extensively on pregnant patients, in large amounts, or for prolonged periods of time.
Nursing Mothers:It is not known whether topical administration of corticosteroids could result in sufficient systemic absorption to produce detectable amounts in breast milk. Systemically administered corticosteroids are secreted into breast milk in quantitites NOT likely to have deleterious effect on the infant. Nevertheless, caution should be exercised when topical corticosteroids are administered to a nursing woman.
Pediatric Use: Pediatric patients may demonstrate greater susceptibility to topical corticosteroid induced HPA axis suppression and Cushing's syndrome, and intracranial hypertension have been reported in children receiving topical corticosteroids.
Manifestations of adrenal suppression in children include linear growth retardation, delayed weight gain, low plasma cortisol levels, and absence of response to ACTH stimulation. Manifestations of intracranial hypertension include bulging fontanelles, headaches, and bilateral papilledema.
Administration of topical corticosteroids to children should be limited to the least amount compatible with an effective therapeutic regimen. Chronic corticosteroid therapy may interfere with the growth and development of children.