ProductQCare Oral Cleansing and Suctioning System compatible with 0.12% Chlorhexidine Gluconate (CHG) Oral Rinse
Active ingredientCETYLPYRIDINIUM CHLORIDE
Label structure10 sections
Indications and uses
Suction Swab with Corinz Antiseptic Cleansing and Moisturizing Oral Rinse Aids in the removal of secretions and debris and helps reduce the chance of infection in minor oral irritation. Suction Toothbrush CHG compatible* Aids in the removal of dental plaque, debris and secretions. Oropharyngeal Suction Catheter Non-sterile Aids in the removal of secretions from the oropharyngeal cavity only.
Dosage and administration
Suction Swab with Antiseptic Oral Rinse Before opening , turn package over, burst solution packet with thumbs. Peel lid to open. Remove Mouth Moisturizer and Applicator Swab. Attach Suction Swab to suction line. Clean teeth and oral cavity for approximately one minute. To suction, place thumb over port. To clear tubing, rinse with sterile saline or appropriate solution. Discard Suction Swab. Reattach Covered Yanka...
Corinz™ Antiseptic Cleansing and Moisturizing Oral Rinse:
Cetylpyridinium chloride 0.05%
Purpose Antiseptic Rinse
*Compatible for use with 0.12% Chlorhexidine Gluconate (CHG) oral rinse, tested for use up to five minutes.
NOTE: The following Uses and Directions refer to the Suction Toothbrush and Swab. For Warnings, Uses and Directions specific to the CHG rinse including use in children under 18 years of age, refer to that product’s package insert and labeling.
Uses
OTC - WHEN USING SECTION
Suction Swab with Corinz Antiseptic Cleansing and Moisturizing Oral Rinse
Aids in the removal of secretions and debris and helps reduce the chance of infection in minor oral irritation.
Suction Toothbrush CHG compatible*
Aids in the removal of dental plaque, debris and secretions.
Oropharyngeal Suction Catheter Non-sterile
Aids in the removal of secretions from the oropharyngeal cavity only.
WARNINGS
WARNINGS SECTION
Stop use and ask a doctor if:
Sore mouth symptoms do not improve in 7 days.
Swelling, rash or fever develops.
Irritation, pain or redness persists or worsens.
OTC - KEEP OUT OF REACH OF CHILDREN SECTION
Keep out of
reach of children. If more than used for antisepsis
is accidentally swallowed, get medical help or contact a Poison Control
Center right away.
Directions
OTC - PURPOSE SECTION
Suction Swab with Antiseptic Oral Rinse Before opening, turn package over, burst solution packet with thumbs.
Peel lid to open.
Remove Mouth Moisturizer and Applicator Swab.
Attach Suction Swab to suction line.
Clean teeth and oral cavity for approximately one minute.
To suction, place thumb over port.
To clear tubing, rinse with sterile saline or appropriate solution.
Discard Suction Swab. Reattach Covered Yankauer to suction line.
Place Mouth Moisturizer on Applicator Swab.
Apply as needed to lips and inside mouth.
Use up to 4 times daily or as directed by a dentist or doctor.
Children under 12 years of age: supervise use.
Children under 3 years of age: consult a dentist or doctor.
Use a bite block when performing oral care on patients with altered levels of consciousness or those who cannot comprehend commands.
Ensure foam is intact after use. If not, remove any particles from oral cavity.
Suction Toothbrush CHG compatible*
Peel lid to open.
Remove Suction Toothbrush and attach to suction line.
When using with a cleansing solution, refer to the product packaging for indications, instructions and warnings.
To suctions, place thumb over port.
To clear tubing, rinse with sterile saline or appropriate solution.
Discard Suction Toothbrush. Reattach Covered Yankauer to suction line.
Use Swab for additional cleansing as needed.
Use two times daily or as directed by a dentist or doctor.
Children under 12 years of age: supervise use.
Children under 3 years of age: consult a dentist or doctor.
Use a bite block when performing oral care on patients with altered levels of consciousness or those who cannot comprehend commands.
Ensure foam is intact after use. If not, remove any particles from oral cavity.
Oropharyngeal Suction Catheter Non-sterile
Peel lid to open.
Attach Suction Catheter to suction line.
Suction secretions from the oropharyngeal cavity.
To suction, place thumb over port.
To clear tubing, rinse with sterile saline or appropriate solution.
Discard Suction Catheter. Reattach Covered Yankauer to suction line.
Use a bite block when performing oral care on patients with altered levels of consciousness or those who cannot comprehend commands.
Oropharyngeal Suction Catheter Non-sterile
Caution
Federal (U.S.A.) law restricts this device to sale by or on the order of a physician or licensed practitioner.
Inactive Ingredients
INACTIVE INGREDIENT SECTION
Suction Swab with Corinz Antiseptic Cleansing and Moisturizing Oral Rinse
OpenFDA label data provides additional search and identifier links. DailyMed’s Structured Product Label is the canonical label on FDA.report. Matching records are deduplicated before they are shown below.