Kit for the Preparation of Technetium Tc99m Pyrophosphate

openFDA label record#

This page contains supplementary openFDA label data. For the canonical label presentation, use the corresponding DailyMed Structured Product Label.

Verified complete openFDA source JSON (canonical bytes are SHA-256 checked before publication)

Brand name
Kit for the Preparation of Technetium Tc99m Pyrophosphate
Generic name
TECHNETIUM TC99M PYROPHOSPHATE
Manufacturer
Sun Pharmaceutical Industries, Inc.
Product type
HUMAN PRESCRIPTION DRUG
SPL set ID
1f0cbd23-2fb3-43b7-b8af-7de246151149
SPL ID
3010b45e-eed1-a5d0-e063-6294a90a40cf
Version
9
Effective date
2025-03-11
Source export date
2026-09-28
Source partition
3
Source file
https://download.open.fda.gov/drug/label/drug-label-0003-of-0014.json.zip
Source object key
raw/openfda/drug-label/2026-09-28/fd09911bd1bc81f7f2faeb048e63855fe224e494376ae919a0035190e315c050/drug-label-0003-of-0014.json.zip
Source manifest SHA-256
cd2e66336a5cd2223fa3995098fdbdb84c6a7ee5c0a4addb236ccb22dd1e6887
Import run
20260929T050834Z
Imported at
2026-09-29 05:20:41
Harmonized routes table
Harmonized routes
INTRAVENOUS

Warnings cross-check#

openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.

Warnings sections page 1 of 1 · 1 matching rows.

warnings

WARNINGS As an adjunct in the diagnosis of confirmed myocardial infarction (ECG and serum enzymes positive), the incidence of false negative images has been found to be 6 percent. False negative images can also occur if made prior to 24 hours in the evolutionary phase of the infarct or after 6 days in the resolution phase. In a limited study involving 22 patients in whom the ECG was positive and serum enzymes questionable or negative, but in whom the final diagnosis of acute myocardial infarction was made, the incidence of false negative images was 23 percent. The incidence of false positive images has been found to be 7 to 9 percent. False positive images have also been reported following coronary by-pass graft surgery, in unstable angina pectoris, old myocardial infarcts and in cardiac contusions. Preliminary reports indicate impairment of brain scans using Sodium Pertechnetate Tc99m Injection which have been preceded by a bone scan using an agent containing stannous ions. The impairment may result in false positive or false negative brain scans. It is recommended, where feasible, that brain scans precede bone imaging procedures. Alternately, a brain imaging agent such as Technetium Tc 99m Pentetate Injection may be employed. The biodistribution of technetium Tc 99m pyrophosphate may be altered in the presence of high levels of certain cations (iron, calcium, and aluminum). This may result in reduced uptake of radionuclide in the skeleton and increased extraosseal uptake, which may potentially degrade imaging quality. High levels of these cations may be caused by concomitant medications or medical conditions (e.g., iron overload, hypercalcemia, etc.). Most cases were observed after iron infusion. (See PRECAUTIONS, Drug Interactions .)

Adverse reactions cross-check#

openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.

Adverse reactions sections page 1 of 1 · 1 matching rows.

adverse reactions

ADVERSE REACTIONS Some hypersensitivity reactions have been associated with pyrophosphate use.

Reported adverse events (FAERS/openFDA)#

Adverse event summaries are temporarily unavailable. Other product information remains available.