Technescan HDP

openFDA label record#

This page contains supplementary openFDA label data. For the canonical label presentation, use the corresponding DailyMed Structured Product Label.

Verified complete openFDA source JSON (canonical bytes are SHA-256 checked before publication)

Brand name
Technescan HDP
Generic name
TECHNETIUM TC 99M OXIDRONATE
Manufacturer
Curium US LLC
Product type
HUMAN PRESCRIPTION DRUG
SPL set ID
6fc2e41e-a1bf-4e0f-924a-88be0372d4af
SPL ID
45357587-3ba3-6414-e063-6294a90a4c26
Version
16
Effective date
2025-12-05
Source export date
2026-09-28
Source partition
9
Source file
https://download.open.fda.gov/drug/label/drug-label-0009-of-0014.json.zip
Source object key
raw/openfda/drug-label/2026-09-28/6784607726c827491ceaeab30d843632e0660ee8008c535197be5ed9e1e52201/drug-label-0009-of-0014.json.zip
Source manifest SHA-256
cd2e66336a5cd2223fa3995098fdbdb84c6a7ee5c0a4addb236ccb22dd1e6887
Import run
20260929T050834Z
Imported at
2026-09-29 06:05:25
Harmonized routes table
Harmonized routes
INTRAVENOUS

Warnings cross-check#

openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.

Warnings sections page 1 of 1 · 1 matching rows.

warnings

WARNINGS Technetium Tc 99m oxidronate may cause life-threatening hypersensitivity reactions. Have cardiopulmonary resuscitation equipment and personnel available and monitor all patients for hypersensitivity reactions. (See ADVERSE REACTION S .) Technetium Tc 99m oxidronate is known to complex cations such as calcium. Particular caution should be used with patients who have or who may be predisposed to hypocalcemia. The biodistribution of technetium Tc 99m oxidronate may be altered in the presence of high levels of certain cations (iron, calcium, and aluminum). This may result in reduced uptake of radionuclide in the skeleton and increased extraosseal uptake, which may potentially degrade imaging quality. High levels of these cations may be caused by concomitant medications or medical conditions (e.g., iron overload, hypercalcemia, etc.). Most cases were observed after iron infusion. (See PRECAUTIONS, Drug Interactions .)

Adverse reactions cross-check#

openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.

Adverse reactions sections page 1 of 1 · 1 matching rows.

adverse reactions

ADVERSE REACTIONS The following adverse reactions associated with the use of Technescan HDP have been reported: hypersensitivity reactions, including life-threatening reactions, as well as nausea, vomiting, and injection site reactions.

Reported adverse events (FAERS/openFDA)#

Adverse event summaries are temporarily unavailable. Other product information remains available.