Noxivent
openFDA label record#
This page contains supplementary openFDA label data. For the canonical label presentation, use the corresponding DailyMed Structured Product Label.
Verified complete openFDA source JSON
- Brand name
- Noxivent
- Generic name
- NITRIC OXIDE
- Manufacturer
- VERO BIOTECH, INC.
- Product type
- HUMAN PRESCRIPTION DRUG
- SPL set ID
- 4ff98b29-bcd3-82eb-e063-6394a90abf8c
- SPL ID
- 4ff98b9d-ce05-2fb7-e063-6294a90a2c96
- Version
- 1
- Effective date
- 2026-04-20
- Source export date
- 2026-10-12
- Source partition
- 10
- Source file
- https://download.open.fda.gov/drug/label/drug-label-0010-of-0014.json.zip
- Source object key
- raw/openfda/drug-label/2026-10-12/befa34274042a52f589b22fe2add0b1c6f0a385c96447c28303de164bb144af5/drug-label-0010-of-0014.json.zip
- Source manifest SHA-256
- 7e6b178df8f32cac9a78e0f5d09c588344509b04fe41effb1dde9102e2a45be6
- Import run
- 20261013T011858Z
- Imported at
- 2026-10-13 02:28:31
| Harmonized routes |
|---|
| RESPIRATORY (INHALATION) |
Harmonized identifier links#
Every typed identifier imported from the complete openFDA harmonization object is paginated here; values are not reduced to a first match.
| Type | Scope | Identifier | Source field |
|---|---|---|---|
| application applno | ANDA | 207141 | derived:openfda.application_number |
| application number | ANDA207141 | openfda.application_number | |
| brand name | Noxivent | openfda.brand_name | |
| generic name | NITRIC OXIDE | openfda.generic_name | |
| manufacturer name | VERO BIOTECH, INC. | openfda.manufacturer_name | |
| ndc | package | 72385-102-02 | openfda.package_ndc |
| ndc | package | 72385-102-01 | openfda.package_ndc |
| ndc | product | 72385-102 | openfda.product_ndc |
| ndc11 | package | 72385010201 | derived:openfda.package_ndc |
| ndc11 | package | 72385010202 | derived:openfda.package_ndc |
| rxcui | 582608 | openfda.rxcui | |
| rxcui | 2743256 | openfda.rxcui | |
| spl id | 4ff98b9d-ce05-2fb7-e063-6294a90a2c96 | id | |
| spl set id | 4ff98b29-bcd3-82eb-e063-6394a90abf8c | set_id | |
| unii | 31C4KY9ESH | openfda.unii |
Warnings cross-check#
openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.
5.3 Airway Injury from Nitrogen Dioxide Nitrogen dioxide (NO 2 ) forms in gas mixtures containing NO and O 2 . Nitrogen dioxide may cause airway inflammation and damage to lung tissues. If there is an unexpected change in NO 2 concentration, or if the NO 2 concentration reaches 3 ppm when measured in the breathing circuit, then the delivery system should be assessed in accordance with the Nitric Oxide Delivery System O&M Manual troubleshooting section, and the NO 2 analyzer should be recalibrated. The dose of Noxivent™ and/or FiO 2 should be adjusted as appropriate.
warnings and cautions
5.4 Worsening Heart Failure Patients with left ventricular dysfunction treated with Noxivent™ may experience pulmonary edema, increased pulmonary capillary wedge pressure, worsening of left ventricular dysfunction, systemic hypotension, bradycardia and cardiac arrest. Discontinue Noxivent™ while providing symptomatic care.
Adverse reactions cross-check#
openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.
adverse reactions
ADVERSE REACTIONS The most common adverse reaction is hypotension. ( 6 ). To report SUSPECTED ADVERSE REACTIONS, contact contact Vero Biotech at 1-833-669-8368 and http://www.vero-biotech.com/ or FDA at 1-800-FDA-1088 or or www.fda.gov/medwatch .
adverse reactions
6. ADVERSE REACTIONS The following adverse reactions are discussed elsewhere in the label; Hypoxemia [see Warnings and Precautions (5.2 )] Worsening Heart Failure [see Warnings and Precautions (5.4 )]
adverse reactions
6.1 Clinical Trials Experience Because clinical trials are conducted under widely varying conditions, adverse reaction rates observed in the clinical trials of a drug cannot be directly compared to rates in the clinical trials of another drug and may not reflect the rates observed in practice. The adverse reaction information from the clinical studies does, however, provide a basis for identifying the adverse events that appear to be related to drug use and for approximating rates. Controlled studies have included 325 patients on nitric oxide doses of 5 to 80 ppm and 251 patients on placebo. Total mortality in the pooled trials was 11% on placebo and 9% on nitric oxide, a result adequate to exclude nitric oxide mortality being more than 40% worse than placebo. In both the NINOS and CINRGI studies, the duration of hospitalization was similar in nitric oxide and placebo-treated groups. From all controlled studies, at least 6 months of follow-up is available for 278 patients who received nitric oxide and 212 patients who received placebo. Among these patients, there was no evidence of an adverse effect of treatment on the need for rehospitalization, special medical services, pulmonary disease, or neurological sequelae. In the NINOS study, treatment groups were similar with respect to the incidence and severity of intracranial hemorrhage, Grade IV hemorrhage, periventricular leukomalacia, cerebral infarction, seizures requiring anticonvulsant therapy, pulmonary hemorrhage, or gastrointestinal hemorrhage. In CINRGI, the only adverse reaction (>2% higher incidence on nitric oxide than on placebo) was hypotension (14% vs. 11%).
adverse reactions
6.2 Post-Marketing Experience Post marketing reports of accidental exposure to nitric oxide for inhalation in hospital staff has been associated with chest discomfort, dizziness, dry throat, dyspnea, and headache.
Reported adverse events (FAERS/openFDA)#
Adverse event summaries are temporarily unavailable. Other product information remains available.