Noxivent
openFDA label record#
This page contains supplementary openFDA label data. For the canonical label presentation, use the corresponding DailyMed Structured Product Label.
Verified complete openFDA source JSON
- Brand name
- Noxivent
- Generic name
- NITRIC OXIDE
- Manufacturer
- VERO BIOTECH, INC.
- Product type
- HUMAN PRESCRIPTION DRUG
- SPL set ID
- 4ff98b29-bcd3-82eb-e063-6394a90abf8c
- SPL ID
- 4ff98b9d-ce05-2fb7-e063-6294a90a2c96
- Version
- 1
- Effective date
- 2026-04-20
- Source export date
- 2026-09-28
- Source partition
- 10
- Source file
- https://download.open.fda.gov/drug/label/drug-label-0010-of-0014.json.zip
- Source object key
- raw/openfda/drug-label/2026-09-28/4bbc9760f647649b787710953d978bd6419e899ba8b90f32c3d972aae43947f8/drug-label-0010-of-0014.json.zip
- Source manifest SHA-256
- cd2e66336a5cd2223fa3995098fdbdb84c6a7ee5c0a4addb236ccb22dd1e6887
- Import run
- 20260929T050834Z
- Imported at
- 2026-09-29 06:06:32
| Harmonized routes |
|---|
| RESPIRATORY (INHALATION) |
Harmonized identifier links#
Every typed identifier imported from the complete openFDA harmonization object is paginated here; values are not reduced to a first match.
| Type | Scope | Identifier | Source field |
|---|---|---|---|
| application applno | ANDA | 207141 | derived:openfda.application_number |
| application number | ANDA207141 | openfda.application_number | |
| brand name | Noxivent | openfda.brand_name | |
| generic name | NITRIC OXIDE | openfda.generic_name | |
| manufacturer name | VERO BIOTECH, INC. | openfda.manufacturer_name | |
| ndc | package | 72385-102-02 | openfda.package_ndc |
| ndc | package | 72385-102-01 | openfda.package_ndc |
| ndc | product | 72385-102 | openfda.product_ndc |
| ndc11 | package | 72385010201 | derived:openfda.package_ndc |
| ndc11 | package | 72385010202 | derived:openfda.package_ndc |
| rxcui | 582608 | openfda.rxcui | |
| rxcui | 2743256 | openfda.rxcui | |
| spl id | 4ff98b9d-ce05-2fb7-e063-6294a90a2c96 | id | |
| spl set id | 4ff98b29-bcd3-82eb-e063-6394a90abf8c | set_id | |
| unii | 31C4KY9ESH | openfda.unii |
Warnings cross-check#
openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.
WARNINGS AND PRECAUTIONS Rebound: Abrupt discontinuation of Noxivent™ may lead to worsening oxygenation and increasing pulmonary artery pressure ( 5.1 ). Methemoglobinemia: Methemoglobin increases with the dose of nitric oxide; following discontinuation or reduction of nitric oxide, methemoglobin levels return to baseline over a period of hours ( 5.2 ). Elevated NO 2 Levels: Monitor NO 2 levels ( 5.3 ). Heart Failure: In patients with pre-existing left ventricular dysfunction, Noxivent™ may increase pulmonary capillary wedge pressure leading to pulmonary edema ( 5.4 ).
warnings and cautions
5. WARNINGS AND PRECAUTIONS
warnings and cautions
5.1 Rebound Pulmonary Hypertension Syndrome following Abrupt Discontinuation Wean from Noxivent™ [see Dosage and Administration (2.2 )]. Abrupt discontinuation of Noxivent™ may lead to worsening oxygenation and increasing pulmonary artery pressure, i.e., Rebound Pulmonary Hypertension Syndrome. Signs and symptoms of Rebound Pulmonary Hypertension Syndrome include hypoxemia, systemic hypotension, bradycardia, and decreased cardiac output. If Rebound Pulmonary Hypertension occurs, reinstate Noxivent™ therapy immediately.
warnings and cautions
5.2 Hypoxemia from Methemoglobinemia Nitric oxide combines with hemoglobin to form methemoglobin, which does not transport oxygen. Methemoglobin levels increase with the dose of Noxivent™; it can take 8 hours or more before steady-state methemoglobin levels are attained. Monitor methemoglobin and adjust the dose of Noxivent™ to optimize oxygenation. If methemoglobin levels do not resolve with decrease in dose or discontinuation of Noxivent™, additional therapy may be warranted to treat methemoglobinemia [see Overdosage (10 )].
Adverse reactions cross-check#
openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.
adverse reactions
ADVERSE REACTIONS The most common adverse reaction is hypotension. ( 6 ). To report SUSPECTED ADVERSE REACTIONS, contact contact Vero Biotech at 1-833-669-8368 and http://www.vero-biotech.com/ or FDA at 1-800-FDA-1088 or or www.fda.gov/medwatch .
adverse reactions
6. ADVERSE REACTIONS The following adverse reactions are discussed elsewhere in the label; Hypoxemia [see Warnings and Precautions (5.2 )] Worsening Heart Failure [see Warnings and Precautions (5.4 )]
adverse reactions
6.1 Clinical Trials Experience Because clinical trials are conducted under widely varying conditions, adverse reaction rates observed in the clinical trials of a drug cannot be directly compared to rates in the clinical trials of another drug and may not reflect the rates observed in practice. The adverse reaction information from the clinical studies does, however, provide a basis for identifying the adverse events that appear to be related to drug use and for approximating rates. Controlled studies have included 325 patients on nitric oxide doses of 5 to 80 ppm and 251 patients on placebo. Total mortality in the pooled trials was 11% on placebo and 9% on nitric oxide, a result adequate to exclude nitric oxide mortality being more than 40% worse than placebo. In both the NINOS and CINRGI studies, the duration of hospitalization was similar in nitric oxide and placebo-treated groups. From all controlled studies, at least 6 months of follow-up is available for 278 patients who received nitric oxide and 212 patients who received placebo. Among these patients, there was no evidence of an adverse effect of treatment on the need for rehospitalization, special medical services, pulmonary disease, or neurological sequelae. In the NINOS study, treatment groups were similar with respect to the incidence and severity of intracranial hemorrhage, Grade IV hemorrhage, periventricular leukomalacia, cerebral infarction, seizures requiring anticonvulsant therapy, pulmonary hemorrhage, or gastrointestinal hemorrhage. In CINRGI, the only adverse reaction (>2% higher incidence on nitric oxide than on placebo) was hypotension (14% vs. 11%).
adverse reactions
6.2 Post-Marketing Experience Post marketing reports of accidental exposure to nitric oxide for inhalation in hospital staff has been associated with chest discomfort, dizziness, dry throat, dyspnea, and headache.
Reported adverse events (FAERS/openFDA)#