FDA label 6e17a5e4-bc6a-418f-a09d-01b4f789b21e

openFDA label record#

This page contains supplementary openFDA label data. For the canonical label presentation, use the corresponding DailyMed Structured Product Label.

Verified complete openFDA source JSON (canonical bytes are SHA-256 checked before publication)

SPL set ID
571577b1-2160-4c2f-b953-062c15373fcb
SPL ID
6e17a5e4-bc6a-418f-a09d-01b4f789b21e
Version
3
Effective date
2009-08-24
Source export date
2026-10-12
Source partition
11
Source file
https://download.open.fda.gov/drug/label/drug-label-0011-of-0014.json.zip
Source object key
raw/openfda/drug-label/2026-10-12/a497e765d824a2e2aa9e88d5f0eea2aae9dcba363989e5f163395cda5c3c9dd8/drug-label-0011-of-0014.json.zip
Source manifest SHA-256
7e6b178df8f32cac9a78e0f5d09c588344509b04fe41effb1dde9102e2a45be6
Import run
20261013T011858Z
Imported at
2026-10-13 02:47:51

Warnings cross-check#

openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.

Warnings sections page 1 of 1 · 1 matching rows.

warnings and cautions

IV. Warnings and Precautions For in vitro diagnostic use only. The Pranactin ® -Citric drug solution is taken orally as part of the diagnostic procedure. Phenylketonurics: Contains Phenylalanine (one of the protein components of Aspartame), 84 mg per dosage unit. (For reference, 12 ounces of typical diet cola soft drinks contain approximately 80 mg of Phenylalanine.) A negative result does not rule out the possibility of Helicobacter pylori infection. False negative results do occur with this procedure. If clinical signs are suggestive of H. pylori infection, retest with a new sample or an alternate method. Antimicrobials, proton pump inhibitors, and bismuth preparations are known to suppress H. pylori . Ingestion of these within two (2) weeks prior to performing the BreathTek™ UBT may give false negative results. A false positive test may occur due to urease associated with other gastric spiral organisms observed in humans such as Helicobacter heilmannii. Premature POST-DOSE breath collection time can lead to a false negative diagnosis for a patient with a marginally positive BreathTek™ UBT result. A false positive test could occur in patients who have achlorhydria. 8 If particulate matter is visible in the reconstituted Pranactin ® -Citric solution after thorough mixing, the solution should not be used.

Reported adverse events (FAERS/openFDA)#

Adverse event summaries are temporarily unavailable. Other product information remains available.