FDA label 911326d2-e19c-45a5-8db3-ac82cb2fac50
openFDA label record#
This page contains supplementary openFDA label data. For the canonical label presentation, use the corresponding DailyMed Structured Product Label.
Verified complete openFDA source JSON
- SPL set ID
- 36009e1e-4b69-4cb0-bd3a-3c6115c1fcf9
- SPL ID
- 911326d2-e19c-45a5-8db3-ac82cb2fac50
- Version
- 7
- Effective date
- 2017-12-20
- Source export date
- 2026-09-28
- Source partition
- 9
- Source file
- https://download.open.fda.gov/drug/label/drug-label-0009-of-0014.json.zip
- Source object key
- raw/openfda/drug-label/2026-09-28/6784607726c827491ceaeab30d843632e0660ee8008c535197be5ed9e1e52201/drug-label-0009-of-0014.json.zip
- Source manifest SHA-256
- cd2e66336a5cd2223fa3995098fdbdb84c6a7ee5c0a4addb236ccb22dd1e6887
- Import run
- 20260929T050834Z
- Imported at
- 2026-09-29 05:59:46
Harmonized identifier links#
Every typed identifier imported from the complete openFDA harmonization object is paginated here; values are not reduced to a first match.
| Type | Scope | Identifier | Source field |
|---|---|---|---|
| spl id | 911326d2-e19c-45a5-8db3-ac82cb2fac50 | id | |
| spl set id | 36009e1e-4b69-4cb0-bd3a-3c6115c1fcf9 | set_id |
Warnings cross-check#
openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.
5 WARNINGS AND PRECAUTIONS Corneal toxicity: Prolonged use or abuse may lead to corneal epithelial toxicity and manifest as epithelial defects which may progress to permanent corneal damage. ( 5.1 ) Corneal injury: Patients should not touch the eye for approximately 20 minutes after using anesthetic as accidental injuries can occur due to insensitivity of the eye. ( 5.2 ) 5.1 Corneal Toxicity Prolonged use or abuse may lead to corneal epithelial toxicity which may manifest as epithelial defects and progress to permanent corneal opacification with accompanying visual loss. 5.2 Corneal Injury Due to Insensitivity Patient should not touch the eye for approximately 20 minutes after using this anesthetic as accidental injuries can occur due to insensitivity of the eye.
Adverse reactions cross-check#
openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.
adverse reactions
6 ADVERSE REACTIONS The following ocular adverse reactions are described elsewhere in the labeling: Corneal Toxicity [ see Warnings and Precautions (5.1) ] Corneal Injury due to Insensitivity [ see Warnings and Precautions (5.2) ] The following adverse reactions have been identified following use of fluorescein sodium and benoxinate hydrochloride ophthalmic solution 0.25% / 0.4%: ocular hyperemia, burning, stinging, eye irritation, blurred vision and punctate keratitis. Because these reactions were reported voluntarily from a population of uncertain size, it is not always possible to reliably estimate their frequency or establish a causal relationship to drug exposure. The most common ocular adverse events are: stinging, burning and conjunctival redness. ( 6 ) To report SUSPECTED ADVERSE REACTIONS, contact Altaire Pharmaceuticals, Inc., at 1-800-258-2471 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch.
Reported adverse events (FAERS/openFDA)#
Adverse event summaries are temporarily unavailable. Other product information remains available.