Kit for the Preparation of Technetium Tc 99m Sulfur Colloid

openFDA label record#

This page contains supplementary openFDA label data. For the canonical label presentation, use the corresponding DailyMed Structured Product Label.

Verified complete openFDA source JSON (canonical bytes are SHA-256 checked before publication)

Brand name
Kit for the Preparation of Technetium Tc 99m Sulfur Colloid
Generic name
TECHNETIUM TC 99M SULFUR COLLOID KIT
Manufacturer
Jubilant DraxImage Inc., dba Jubilant Radiopharma
Product type
HUMAN PRESCRIPTION DRUG
SPL set ID
f756e00e-0acd-4c5d-97f8-ed57f23a2393
SPL ID
92a1bc37-cc23-4498-ad61-29347c3876dc
Version
6
Effective date
2023-12-05
Source export date
2026-10-12
Source partition
3
Source file
https://download.open.fda.gov/drug/label/drug-label-0003-of-0014.json.zip
Source object key
raw/openfda/drug-label/2026-10-12/f40eac55ff4c5d55c3d8bbc5766ea7e21e4196960cfb4703b96a406b491c0cd5/drug-label-0003-of-0014.json.zip
Source manifest SHA-256
7e6b178df8f32cac9a78e0f5d09c588344509b04fe41effb1dde9102e2a45be6
Import run
20261013T011858Z
Imported at
2026-10-13 01:30:46

Warnings cross-check#

openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.

Warnings sections page 1 of 1 · 1 matching rows.

warnings and cautions

5 WARNINGS AND PRECAUTIONS Anaphylactic reactions including rare fatalities have occurred following intravenously administered Technetium Tc 99m Sulfur Colloid. Have resuscitation equipment and personnel immediately available. (5.1) 5.1 Anaphylactic Reactions Anaphylactic reactions with bronchospasm, hypotension, urticaria and rare fatalities have occurred following intravenously administered Technetium Tc 99m Sulfur Colloid Injection. Have emergency resuscitation equipment and personnel immediately available. 5.2 Radiation Risks Radiation-emitting products, including Technetium Tc 99m Sulfur Colloid Injection, may increase the risk for cancer, especially in pediatric patients. Use the smallest dose necessary for imaging and ensure safe handling to protect the patient and health care worker. [see Dosage and Administration (2.3)] 5.3 Altered Distribution, Accumulation of Tracer in the Lungs Technetium Tc 99m Sulfur Colloid Injection is physically unstable, and the particles will settle with time or with exposure to polyvalent cations. These larger particles are likely to be trapped by the pulmonary capillary bed following intravenous injection and result in non-uniform distribution of radioactivity. Agitate the vial adequately before administration of sulfur colloid to avoid particle aggregation and non-uniform distribution of radioactivity. Discard unused drug after 6 hours from the time of formulation. [see Dosage and Administration (2.2)]

Adverse reactions cross-check#

openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.

Adverse reactions sections page 1 of 1 · 1 matching rows.

adverse reactions

6 ADVERSE REACTIONS The most frequently reported adverse reactions, across all categories of use and routes of administration, include rash, allergic reaction, urticaria, anaphylaxis/anaphylactic shock, and hypotension. Less frequently reported adverse reactions are fatal cardiopulmonary arrest, seizures, dyspnea, bronchospasm, abdominal pain, flushing, nausea, vomiting, itching, fever, chills, perspiration, numbness, and dizziness. Local injection site reactions, including burning, blanching, erythema, sclerosis, swelling, eschar, and scarring, have also been reported. The most frequently reported adverse reactions include rash, urticaria, anaphylactic shock, and hypotension. (6) To report SUSPECTED ADVERSE REACTIONS, contact Jubilant DraxImage Inc., dba Jubilant Radiopharma TM at 1-888-633-5343 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch.

Reported adverse events (FAERS/openFDA)#

Adverse event summaries are temporarily unavailable. Other product information remains available.