FDA label b8a2c0df-591c-73c8-e053-2a95a90ac408

openFDA label record#

This page contains supplementary openFDA label data. For the canonical label presentation, use the corresponding DailyMed Structured Product Label.

Verified complete openFDA source JSON (canonical bytes are SHA-256 checked before publication)

SPL set ID
05f1030d-1a9c-05df-e054-00144ff8d46c
SPL ID
b8a2c0df-591c-73c8-e053-2a95a90ac408
Version
4
Effective date
2021-01-11
Source export date
2026-08-01
Source partition
1
Source file
https://download.open.fda.gov/drug/label/drug-label-0001-of-0014.json.zip
Source object key
raw/openfda/drug-label/2026-08-01/0689a4374f1490600b5244071db3b04bd3bbc29ceda7a856edb8225323adf20a/drug-label-0001-of-0014.json.zip
Source manifest SHA-256
bdd1454d0606b622b70458a306b8a10d8a8787db06fd9f46e69c7f7a4524b630
Import run
20260801T225920Z
Imported at
2026-08-01 23:00:43

Warnings cross-check#

openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.

Warnings sections page 1 of 1 · 1 matching rows.

warnings

WARNINGS: Serious adverse reactions, including death, have been reported with the administration of barium sulfate formulations and are usually associated with the technique of administration, the underlying pathological condition and/or patient hypersensitivities.

Adverse reactions cross-check#

openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.

Adverse reactions sections page 1 of 1 · 1 matching rows.

adverse reactions

ADVERSE REACTIONS: Adverse reactions accompanying the use of barium sulfate formulations are infrequent and usually mild, though severe reactions (approximately 1 in 500,000) and fatalities (approximately 1 in 2,000,000) have occurred. Procedural complications are rare, but may include aspiration pneumonitis, barium sulfate impaction, granuloma formation, intravasation, embolization and peritonitis following intestinal perforation, vasovagal and syncopal episodes, and fatalities. EKG changes have been shown to occur following or during barium sulfate suspension enemas. It is of the utmost importance to be completely prepared to treat any such occurrence. Due to the increased likelihood of allergic reactions in atopic patients, a complete history of known and suspected allergies as well as allergic-like symptoms, e.g. rhinitis, bronchial asthma, eczema and urticaria, must be obtained prior to any medical procedure. Aspiration of large amounts of barium sulfate suspension may cause pneumonitis or nodular granulomas of interstitial lung tissues and lymph nodes; asphyxiation and death have been reported. Transient bacteremia, beginning almost immediately and lasting up to 15 minutes, may also occur during rectal administration of barium sulfate suspension, and rarely septicemia has been reported. A rare mild allergic reaction would most likely be generalized pruritis, erythema or urticaria (approximately 1 in 100,000 reactions). Such reactions will often respond to an antihistamine. More serious reactions (approximately 1 in 500,000) may result in laryngeal edema, bronchospasm or hypotension. Severe reactions which may require emergency measures are often characterized by peripheral vasodilation, hypotension, reflex tachycardia, dyspnea, bronchospasm, agitation, confusion and cyanosis, progressing to unconsciousness. Treatment should be initiated immediately according to established standard of care. Apprehensive patients may develop weakness, pallor, tinnitus, diaphoresis and bradycardia following the administration of any diagnostic agent. Such reactions are usually non-allergic in nature. Allergic reactions to the enema accessories, in particular to retention catheters (tips) with latex cuffs, can occur. Such reactions could occur immediately and result in the previously mentioned acute allergic-like responses or might be delayed in appearance and result in a contact dermatitis. Known atopic patients, particularly those with a history of asthma or eczema, should be evaluated for alternative methods of administration in order to avoid these adverse reactions. These plastic/rubber accessories are disposable, single-use devices that must not be reused or left in the body cavity for an extended period of time.